55
Technical Details
Dimensions (in cm):
Height (Extraction mode):
65-107
Height (Recirculation mode):
72-114
Width:
150
Depth:
51,5
Maximum absorbed power:
200 W
Motor absorption:
160 W
Lighting:
2 x 20 W (G4)
Length of the cable (in cm):
130
Electrical connection:
220-240 V
Fuse rating:
5At
Mounting accessories included
1 chimney support
1 deflector
10 screws 5 x 45 mm (for wall mounting)
10 Wall dowels Ø 8 mm (for wall mounting)
2 Hooks with wall dowels
1 flange Ø 150 mm
1 flange Ø 125 mm
4 screws 3 x 9
4 screws 3 x 15
1 allan wrench for torx screws
Electrical connection
Safety warnings for the electrician
The mains power supply must correspond to the rating indicated on the
plate situated inside the hood. If provided with a plug connect the hood
to a socket in compliance with current regulations and positioned in an
accessible area. If it not fitted with a plug (direct mains connection) or if
the plug is not located in an accessible area apply a bi-polar switch in
accordance with standards which assures the complete disconnection
of the mains under conditions relating to over-current category III, in
accordance with installation instructions.
IMPORTANT: Before re-connecting the hood circuit to the mains supply
and checking the efficient function, always check that the mains cable
is correctly assembled.
IMPORTANT! Power cable replacement must be undertaken by the
authorized service assistance centre or similar qualified person.