Ensure to avoid shadowing from module clamps. Please
refer to figure 4 and figure 6, and paragraph 3.2.4
„Loading capacity“ for details on the individual product
series.
Figure 4: Clamping
3.2.3 Insertion systems
AEG solar modules are compatible with the insertion
systems of selected manufacturers. For more
information, and for a compatibility assessment of the
insertion system you wish to use, contact the AEG
service team (see Section 6 „Contact“).
3.2.4 Loading capacity
The PV module‘s load resistance is rated as:
Wind load: 2400 Pa / Snow load: 5400 Pa.
Please note this could vary according to the different
mounting systems and configurations.
For standard conditions, low loading capacity applies:
AEG modules are tested under a maximum positive
pressure of 2400 Pa, and negative pressure of 2400 Pa.
For extreme conditions (e.g.: heavy snow), high loading
capacity applies: AEG modules are tested under a
maximum positive pressure of 5400 Pa, and negative
pressure of 2400 Pa.
Please note the indications in the below pictures:
L=module length (module long side)
W=module width (module short side)
X, Y=clamp installation point/
(arrows) bolting/clamping points
Mounting with bolts
Module series:
AS-Mxxx2,
AS-Mxxx9, AS-Pxxx9
Module series: AS-Mxxx2,
AS-Mxxx8, AS-Pxxx8,
AS-Mxxx9, AS-Pxxx9
Load:
positive 2400Pa
negative 2400 Pa
Load
positive 5400 Pa
negative 2400 Pa
Module series:
AS-M1203 (G1), AS-M1203 (M6),
AS-M3607-S (G1)
Module series:
AS-M1443 (G1),
AS-M1443 (M6)
Load:
positive 5400Pa
negative 2400 Pa
Load
positive 5400 Pa
negative 2400 Pa
Module series:
AS-M1443 (G1),
AS-M1443 (M6)
Module series:
AS-M4327-S(G1)
AS-M4327-S(G1)*
Load:
positive 2400Pa
negative 2400 Pa
Load:
positive 5400Pa
negative 2400 Pa
*
=add in case of extreme environmental conditions
Module series:
AS-M1443 (G1)
Module series:
AS-M1443 (M6)
(Pitch bolt) Load:
positive 2400Pa
negative 2400 Pa
(Pitch bolt) Load:
positive 2400Pa
negative 1700 Pa
400 mm
400 mm
Figure 5: Bolting, loading capacity scheme
PV module
Frame
Mounting
rails
Clamp B
Flat washer
Spring washer
Nut
Flat washer
Bolt
PV module
Mounting structure
Bolt
Flat washer
Clamp
Nut
Spring washer
*
*
*
*