1.2 Product Identification
Each module can be identified by means of the
following information:
Product Label
It is placed on the module backside. According to
EN 50380 Directives it provides information about
the main parameters of the module: Product Type,
Maximum Power, Current at Maximum Power, Voltage
at Maximum power, Open Circuit Voltage, Short Circuit
Current -as measured under Standard Test Conditions,
Maximum System Voltage, Maximum Series Fuse etc.
The product label also features the Product Name
Code (PNC).
MONOCRYSTALLINE
PHOTOVOLTAIC
MODULE
Brückenstrasse 94
60594 Frankfurt am Main
Deutschland / Germany
Product assembled in People's Republic of China.
PV Module classification
AEG is a registered trademark used under
license from AB Electrolux (publ).
Solar Solutions GmbH
Class II
www.aeg-industrialsolar.de | +49 (0)69 400500810
Tolerance on Pmax
Tolerance on Voc
Tolerance on Isc
±3%
±3%
±4%
Measured at Standard Test
Conditions (E=1000 W/m
2,
Tc=25°C, AM=1.5)
For field connection please use
minimum Ø 4mm
2
[12 AWG]
copper wires insulated for a
minimum temp. 90°C.
Tested according to
:
IEC 61215-1:2016 IEC 61215-1-1:2016
IEC 61215-2:2016 IEC 61730-1:2016
IEC 61730-2:2016
This photovoltaic module
produces electricity when
exposed to light. Please refer to
the instructions stated in the
mounting manual for proper use.
Hazardous electricity can shock,
burn or cause death.
Do not touch connectors!
Module Type
Maximum Power (Pmax)
Power Sorting
Open Circuit Voltage (Voc)
Short Circuit Current (Isc)
Maximum Power Voltage (Vmp)
Maximum Power Current (Imp)
Maximum System Voltage
Maximum Series Fuse
340
0 ~ 5
41.70
10.40
34.01
10.01
1000
20
W
W
V
A
V
A
V
A
AS-M1202-H(G1)-340
Figure 1: label example
Serial Number
Each individual module is identified by a unique serial
number univocally coupled with a barcode. Serial
number and barcode are permanently placed on the
laminate, under the front glass of the module, and are
visible from the module front.
Connector (+)
Connector (-)
Grounding
holes
(6-ø5.5)
Mounting
holes
(10-9x14)
Drainage
holes
Label
Connectors
Drainage
holes
Junction
box
Mounting
holes
Label
Grounding
holes
Figure 2: Examples of product technical drawings
Please refer to the specific product datasheet on
www.aeg-industrialsolar.de for the latest technical data.
2. SAFETY
2.1 General safety
All AEG PV modules should be installed according to
all local and national applicable standards, codes and
regulations. Only qualified personnel should install
the solar modules. Installers bear the risk of all injury
that might occur during installation including, without
limitation, the risk of electric shock. Check and follow
all safety precautions specified even for the other
components of the system.
Look for any visible damage to the package or the
product itself. Double-check the order information
and the product nameplate to ensure the products
are of the ordered type. Should you find any problems,
contact the shipping company and / or your supplier as
soon as possible before attempting product installation.
2.2 Handling safety
Please observe the below indications when handling
AEG solar modules:
Store the pallets in a ventilated, dry location until
installation. Do not open the module boxes during
storage or transportation. Inappropriate transport and
installation may void the warranty.
Do not apply paint or adhesive to module top
surface.
Do not use mirrors or other magnifiers to
artificially concentrate sunlight on the modules.
Do not expose back sheet foils directly to sunlight.
Do not attempt to disassemble the modules
Do not remove any attached nameplates or components