background image

3

AEG STANDARD MODULE INSTALLATION MANUAL

GD202104 V1-21

EN

Icon

Meaning

Instruction

Prohibited

Damage may occur in case of 
noncompliance with the 
requirement.

Note

Useful information for 
product maintenance and 
operation is provided

Table 1: Icon meaning

1.2 Product Identification

Each module can be identified by means of the 
following information:

Product Label 

It is placed on the module backside. According to 
EN 50380 Directives it provides information about 
the main parameters of the module: Product Type, 
Maximum Power, Current at Maximum Power, Voltage 
at Maximum power, Open Circuit Voltage, Short Circuit 
Current -as measured under Standard Test Conditions, 
Maximum System Voltage, Maximum Series Fuse etc. 
The product label also features the Product Name 
Code (PNC).  

MONOCRYSTALLINE
PHOTOVOLTAIC 
MODULE

Brückenstrasse 94
60594 Frankfurt am Main
Deutschland / Germany

Product assembled in People's Republic of China.

PV Module classification

AEG is a registered trademark used under 

license from AB Electrolux (publ).

Solar Solutions GmbH

 

Class II

www.aeg-industrialsolar.de  | +49 (0)69 400500810

Tolerance on Pmax
Tolerance on Voc
Tolerance on Isc

±3%
±3%
±4%

Measured at Standard Test 
Conditions (E=1000 W/m

2, 

Tc=25°C, AM=1.5) 

For field connection please use 
minimum Ø 4mm

2  

[12 AWG] 

copper wires insulated for a 
minimum temp. 90°C. 

Tested according to

IEC 61215-1:2016   IEC 61215-1-1:2016 

IEC 61215-2:2016  IEC 61730-1:2016 

IEC 61730-2:2016 

This photovoltaic module 
produces electricity when 
exposed to light. Please refer to 
the instructions stated in the 
mounting manual for proper use.

Hazardous electricity can shock, 
burn or cause death. 
Do not touch connectors!

Module Type
Maximum Power (Pmax)

Power Sorting
Open Circuit Voltage (Voc)

Short Circuit Current (Isc)

Maximum Power Voltage (Vmp)

Maximum Power Current (Imp)

Maximum System Voltage
Maximum Series Fuse

340

0 ~ 5

41.70

10.40

34.01

10.01

1000

20

W
W

V
A
V
A
V
A

AS-M1202-H(G1)-340

Figure 1: label example

Serial Number

  

Each individual module is identified by a unique serial 
number univocally coupled with a barcode. Serial 
number and barcode are permanently placed on the 
laminate, under the front glass of the module, and are 
visible from the module front.

Connector (+)

Connector (-)

Grounding 
holes 

(6-ø5.5)

Mounting
holes 

(10-9x14)

 

Drainage
holes

Label

Connectors

Drainage
holes

Junction
box

Mounting
holes 

Label

Grounding 
holes 

Figure 2: Examples of product technical drawings

Please refer to the specific product datasheet on   
www.aeg-industrialsolar.de for the latest technical data.

2. SAFETY

2.1 General safety 

All AEG PV modules should be installed according to 
all local and national applicable standards, codes and 
regulations. Only qualified personnel should install 
the solar modules. Installers bear the risk of all injury 
that might occur during installation including, without 
limitation, the risk of electric shock. Check and follow 
all safety precautions specified even for the other 
components of the system.

Look for any visible damage to the package or the 
product itself. Double-check the order information 
and the product nameplate to ensure the products 
are of the ordered type. Should you find any problems, 
contact the shipping company and / or your supplier as 
soon as possible before attempting product installation.

2.2 Handling safety 

Please observe the below indications when handling 
AEG solar modules: 
 
Store the pallets in a ventilated, dry location until 
installation. Do not open the module boxes during 
storage or transportation. Inappropriate transport and 
installation may void the warranty.

Do not apply paint or adhesive to module top 
surface.
Do not use mirrors or other magnifiers to 

artificially concentrate sunlight on the modules. 
Do not expose back sheet foils directly to sunlight.
Do not attempt to disassemble the modules
Do not remove any attached nameplates or components

Содержание AS-M 2 Series

Страница 1: ...EG STANDARD MODULE INSTALLATION MANUAL GD202104 V1 21 VERSION AEG SOLAR MODULES INSTALLATION MANUAL GLASS BACKSHEET STANDARD MODULE SERIES AS MXXX2 AS MXXX3 AS MXXX7 S AS MXXX8 AS PXXX8 AS MXXX9 AS PXXX9 ...

Страница 2: ...rtant information for product care maintenance and disposal 1 PRELIMINARY REMARKS 1 1 Icons This section describes relevant warning symbols recurring in the installation and operation manual of AEG solar modules Icons highlight relevant information for the physical and property safety of the user Compliance to the provided instructions is essential to prevent physical injury and product damage Bel...

Страница 3: ...ltage Maximum Series Fuse 340 0 5 41 70 10 40 34 01 10 01 1000 20 W W V A V A V A AS M1202 H G1 340 Figure 1 label example Serial Number Each individual module is identified by a unique serial number univocally coupled with a barcode Serial number and barcode are permanently placed on the laminate under the front glass of the module and are visible from the module front Connector Connector Groundi...

Страница 4: ...iring and support frames suitable for use in a solar electric installation Do not wear metallic rings watchbands ear nose or lip rings or other metallic devices while installing or troubleshooting photovoltaic systems in order to avoid electric shock Do not disconnect modules under load to avoid electrical arcs Contact with electrically active parts of the modules such as terminals can result in b...

Страница 5: ...ut of the modules in a photovoltaic system keep suitable access space to allow easy maintenance and inspection works Provide adequate ventilation under the modules for cooling Always use structures and materials specifically developed and certified for photovoltaic module installation AEG PV modules must be installed and stored in the following conditions Operating temperature From 40 C to 85 C Ex...

Страница 6: ...east 60 cm 24 inches For roof mounted systems always ensure the suitability of the roof construction before installing the modules on a roof In addition any point of roof penetration required to mount the modules must be properly sealed to prevent leaks Provide adequate ventilation under the modules in conformity to local regulations A minimum distance of 10 cm between the roof plane and the frame...

Страница 7: ...ive pressure of 5400 Pa and negative pressure of 2400 Pa Please note the indications in the below pictures L module length module long side W module width module short side X Y clamp installation point arrows bolting clamping points Mounting with bolts Module series AS Mxxx2 AS Mxxx9 AS Pxxx9 Module series AS Mxxx2 AS Mxxx8 AS Pxxx8 AS Mxxx9 AS Pxxx9 Load positive 2400Pa negative 2400 Pa Load posi...

Страница 8: ...scheme 3 3 Electrical Installation and Grounding 3 3 1 General remarks Modules electrically connected together in a series parallel configuration generate DC electrical energy which can be converted to AC by mean of a solar inverter When modules are connected in series the total voltage is equal to the sum of individual voltages For applications requiring high currents photovoltaic modules can be ...

Страница 9: ... maximum series fuse rating of the module and local electrical installation codes There is no specific limitation on the number of modules that can be connected in parallel the number of modules is determined by system design parameters such as current or power output To prevent the cables and the connectors from overheating the cross section of the cables and the capacity of the connectors must b...

Страница 10: ... electrical shock hazard Dirt and dust can accumulate on the glass surface of the PV module over time particularly in installations with low inclination This can cause a general decrease of power output and also sedimentation on the lower edge of the modules due to dirt accumulation We recommend a periodic cleaning of PV modules to ensure maximum power output especially in regions with high quanti...

Страница 11: ...nnected with such installation operation use or maintenance No responsibility is assumed by Solar Solutions GmbH for any infringement of patents or other rights of third parties which may result from use of the PV product No license is granted by implication or otherwise under any patent or patent rights 6 CONTACT Solar Solutions GmbH Brückenstrasse 94 60594 Frankfurt am Main Germany www aeg indus...

Отзывы: