AEG STANDARD MODULE INSTALLATION MANUAL

GD202104 V1-21

EN

Do not exceed the maximum stapling limitation of 2 
pallets (standard packaging for shipment).
After unpacking, the modules should be laid 
horizontally. Do not incline or stack the modules.
Do not pile up modules without protections to prevent 
scratches to the glass and frame. Should the modules 
need to be piled, they need to be separated by special 
paper or plastic angles.
Do not scratch or damage the module surface.
Do not drill holes in the frame as it may compromise its 
strength, cause corrosion and void the warranty.
Do not use the junction box and cables as a grip.
Do not drop the module or allow objects to fall on the 
module.
Do not place any heavy objects on the module to avoid 
glass breakage.
Do not stand or step on the module. 
Do not set the module down hard on a surface.

Do not attempt to repair a module with broken 
glass or torn backsheet and do not use it as 
contact with any module surface or the frame 

could cause an electric shock.

2.3 Installation safety 

Installing solar photovoltaic systems requires 
specialized skills and knowledge. Photovoltaic solar 
modules are designed for outdoor use, and may be 
ground mounted as well as mounted on rooftops, 
vehicles or boats. The proper design of support 
structures is a responsibility of the system designer 
and installer. When installing the system, abide with 
all local, regional and national statutory regulations.  
Keep children away from the installation site and 
during transportation and installation of the electrical 
equipment.

Cover the module completely with a dark opaque 
material during installation to prevent electricity 
generation. 
When working with modules without any cover, the 
safety regulations for live electrical equipment need to 
be followed. Use only equipment, connectors, wiring 
and support frames suitable for use in a solar electric 
installation. 

Do not wear metallic rings, watchbands, ear, 
nose or lip rings or other metallic devices while 
installing or troubleshooting photovoltaic 

systems in order to avoid electric shock.
Do not disconnect modules under load to avoid 
electrical arcs.

Contact with electrically active parts of the modules, 
such as terminals, can result in burns, sparks and
lethal shock whether or not the module is connected.
Do not insert electrically conductive parts into the 
plugs and sockets.
Do not install solar modules and wiring with wet plugs 
and sockets.
Exert extreme caution when carrying out any work on 
the wiring. High contact voltages can generate in the 
inverter when it is isolated.
Abide with the safety regulations for all the other 
components used in the PV system, including wiring 
and cables, connectors, charging regulators, inverters, 
storage batteries and rechargeable batteries, etc 
 

One individual module may generate DC 
voltages greater than 30 V when exposed to 
light of any intensity. Contact with a DC voltage 

of 30 V or more is potentially hazardous. The series or 
parallel connection of the modules increases the 
voltage or electric current respectively. The electrical 
characteristics are within the following tolerances of the 
indicated values of Isc, Voc and Pmpp under standard 
test conditions (irradiance of 1000 W/m², AM 1.5 
spectrum, and a cell temperature of 25 °C/77 °F). :

Model

Tolerance

AS-Mxxx2

Isc ±4% 
Voc ±3%
Pmpp ±3%

AS-Mxxx3

Isc ±5% 
Voc ±3%
Pmpp ±3%

AS-Mxxx8 / AS-Pxxx8

Isc ±5% 
Voc ±5%
Pmpp ±5%.

AS-Mxxx7-S /  
AS-Mxxx9 / AS-Pxxx9

Isc ±3% 
Voc ±3%
Pmpp ±3% 

Under normal conditions, a photovoltaic module is 
likely to experience conditions that produce more 
current and/or voltage than reported at standard test 
conditions. Accordingly, the values of Isc and Voc 
marked on the module should be multiplied by a factor 
of 1.25 when determining component voltage ratings, 
conductor current ratings, minimum factor of fuse sizes, 
and size of controls connected to the PV output.
 

Содержание AS-M 2 Series

Страница 1: ...EG STANDARD MODULE INSTALLATION MANUAL GD202104 V1 21 VERSION AEG SOLAR MODULES INSTALLATION MANUAL GLASS BACKSHEET STANDARD MODULE SERIES AS MXXX2 AS MXXX3 AS MXXX7 S AS MXXX8 AS PXXX8 AS MXXX9 AS PXXX9 ...

Страница 2: ...rtant information for product care maintenance and disposal 1 PRELIMINARY REMARKS 1 1 Icons This section describes relevant warning symbols recurring in the installation and operation manual of AEG solar modules Icons highlight relevant information for the physical and property safety of the user Compliance to the provided instructions is essential to prevent physical injury and product damage Bel...

Страница 3: ...ltage Maximum Series Fuse 340 0 5 41 70 10 40 34 01 10 01 1000 20 W W V A V A V A AS M1202 H G1 340 Figure 1 label example Serial Number Each individual module is identified by a unique serial number univocally coupled with a barcode Serial number and barcode are permanently placed on the laminate under the front glass of the module and are visible from the module front Connector Connector Groundi...

Страница 4: ...iring and support frames suitable for use in a solar electric installation Do not wear metallic rings watchbands ear nose or lip rings or other metallic devices while installing or troubleshooting photovoltaic systems in order to avoid electric shock Do not disconnect modules under load to avoid electrical arcs Contact with electrically active parts of the modules such as terminals can result in b...

Страница 5: ...ut of the modules in a photovoltaic system keep suitable access space to allow easy maintenance and inspection works Provide adequate ventilation under the modules for cooling Always use structures and materials specifically developed and certified for photovoltaic module installation AEG PV modules must be installed and stored in the following conditions Operating temperature From 40 C to 85 C Ex...

Страница 6: ...east 60 cm 24 inches For roof mounted systems always ensure the suitability of the roof construction before installing the modules on a roof In addition any point of roof penetration required to mount the modules must be properly sealed to prevent leaks Provide adequate ventilation under the modules in conformity to local regulations A minimum distance of 10 cm between the roof plane and the frame...

Страница 7: ...ive pressure of 5400 Pa and negative pressure of 2400 Pa Please note the indications in the below pictures L module length module long side W module width module short side X Y clamp installation point arrows bolting clamping points Mounting with bolts Module series AS Mxxx2 AS Mxxx9 AS Pxxx9 Module series AS Mxxx2 AS Mxxx8 AS Pxxx8 AS Mxxx9 AS Pxxx9 Load positive 2400Pa negative 2400 Pa Load posi...

Страница 8: ...scheme 3 3 Electrical Installation and Grounding 3 3 1 General remarks Modules electrically connected together in a series parallel configuration generate DC electrical energy which can be converted to AC by mean of a solar inverter When modules are connected in series the total voltage is equal to the sum of individual voltages For applications requiring high currents photovoltaic modules can be ...

Страница 9: ... maximum series fuse rating of the module and local electrical installation codes There is no specific limitation on the number of modules that can be connected in parallel the number of modules is determined by system design parameters such as current or power output To prevent the cables and the connectors from overheating the cross section of the cables and the capacity of the connectors must b...

Страница 10: ... electrical shock hazard Dirt and dust can accumulate on the glass surface of the PV module over time particularly in installations with low inclination This can cause a general decrease of power output and also sedimentation on the lower edge of the modules due to dirt accumulation We recommend a periodic cleaning of PV modules to ensure maximum power output especially in regions with high quanti...

Страница 11: ...nnected with such installation operation use or maintenance No responsibility is assumed by Solar Solutions GmbH for any infringement of patents or other rights of third parties which may result from use of the PV product No license is granted by implication or otherwise under any patent or patent rights 6 CONTACT Solar Solutions GmbH Brückenstrasse 94 60594 Frankfurt am Main Germany www aeg indus...

Отзывы: