33
PD201806 AEG GRID-TIED SINGLE-PHASE SOLAR INVERTER V.1-18 EN
33
Setting item
LCD display
Instruction
Set power
Accessing the “Set power” interface requires a password.
The default password is: 2678..
The Set power interface features 3 submenus:
①
P-Lmt Mode: invalid (limited power function is invalid),
auto (special for single-phase), manual (set the limit of
output value manually);
②
LmtPower: this function is only valid when the P-Lmt
Mode is manual, the percentage is that of the rated power
and the setting range is from 10% to 100%;
③
p.Factor: includes normal model (default value “1”),
current advanced mode and current hysteresis mode and
the setting rage is -0.9-0.99.
(three-phase inverters only have function nr.
③
)
Personal
This function is only valid for single-phase inverters.
Accessing the “Personal” interface requires a password.
The default password is: 2678...
. The MPPT starting voltage can be set in this menu from
120V to 160V under the submenu of ”MPPT start volt”.