12
PD201806 AEG GRID-TIED SINGLE-PHASE SOLAR INVERTER V.1-18 EN
12
2.4 Technical parameters
Below is an overview of the technical parameters of the product in series AS-IR01 and AS-IR01-2. Technical specifications
are subject to change without previous notice. Please refer to the related product datasheet which you can also find
under
www.aeg-industrialsolar.de
> Service > Product Datasheet for the latest parameters.
Model
AS-IR01-xxx
(xxx= 750 to 5000)
AS-IR01-xxx-2
(xxx= 3000 to 5000)
750
1000
1500
2000
3000
4000
4600
5000
3000
4000
4600
5000
DC side
Vmax
PV 400 450 450 450 500 600 600 600 600 600 600 600
Recomme
nded Max.
DC voltage
(V)
400 450 450 450 500 550 550 550 550 550 550 550
Starting
voltage
(V)
60 80 80 80 80 120 120 120 120 120 120 120
MPPT
voltage(V)
50-
400
60-
400
80-
410
100-
410
120-
450
120-
550
120-
550
120-
550
120-
550
120-
550
120-
550
120-
550
MPPT/stri
ngs per
MPPT
1/1 1/1 1/1 1/1 1/2 1/2 1/2 1/2 2/1 2/1 2/1 2/1
Max. DC
power (W)
900 1200 1700 2200 3300 4800 5520 6000 3600 4800 5520 6000
Max. input
current (A)
8x1 9x1 10x1 12×1 15×1 16×1 18×1 20×1 8×2 10×2 11×2 12×2
DC switch
Integrated
Integrated
Integrated
AC side
Max.
Continuou
s output
power (W)
750 1000 1500 2000 3000 3680 4200 4600 3000 3680 4200 4600
Nominal
voltage /
frequency
Single phase, 230 Vac, 50 Hz
Voltage(V)
range /
frequency
(Hz) range
180~270Vac
、
50Hz(47~51.5Hz)
According to VDE0126& AR-N4105, C10/11
Max. AC
current (A)
3.6 4.5 6.5 9 13 16 18.3
20 14 16 18.3 20
Power
factor
≥
0,99 (rated load)
-0.95~+0.95 (adjustable)
Harmonic
distortion
< 3% (rated power
)
System
Cooling
Natural cooling
Natural cooling
Maximum
efficiency
96.80%
96.90
%
97.20% 97.20% 97.30% 97.70%
97.70% 97.80
%
97.70% 97.70% 97.70% 97.80%
European
efficiency
95.95%
96.00
%
96.10% 96.10%
96.50
%
96.50%
96.70% 96.80
%
96.70% 96.70% 96.70% 96.80%
MPPT
efficiency
99.9%