22
TECHNICAL DATA ON THE DATA LABEL
4 BURNERS
LPG = 30 mbar
TOWN = 10 mbar
Tot. Nom. Gas Rate = 7.5 kW
Tot.Nom.H.K.Towngas Rate = 7.5 kW
Tot. Nom. LPG = 545 g/h
Voltage = 230 – 240 V ~
Frequency = 50/60 Hz
3 B
1 NORMAL PLATE
LPG = 30 mbar
TOWN = 10 mbar
Tot. Nom. Gas Rate = 5.75 kW
Tot.Nom.H.K.Towngas Rate = 5.75 kW
Tot. Nom. LPG = 418 g/h
Voltage = 230 – 240 V ~
Frequency = 50/60 Hz
Pot. Nom. El. Rating = 1000 W
3 B
1 RAPID PLATE
LPG = 30 mbar
TOWN = 10 mbar
Tot. Nom. Gas Rate = 5.75 kW
Tot.Nom.H.K.Towngas Rate = 5.75 kW
Tot. Nom. LPG = 418 g/h
Voltage = 230 – 240 V ~
Frequency = 50/60 Hz
Pot. Nom. El. Rating = 1500 W
4 BURNERS WITH UR
LPG = 30 mbar
TOWN = 10 mbar
Tot. Nom. Gas Rate = 7.85 kW
Tot.Nom.H.K.Towngas Rate = 7.6 kW
Tot. Nom. LPG = 571 g/h
Voltage = 230 – 240 V ~
Frequency = 50/60 Hz
3 BURNERS WITH UR+
1 NORMAL PLATE
LPG = 30 mbar
TOWN = 10 mbar
Tot. Nom. Gas Rate = 6.1 kW
Tot.Nom.H.K.Towngas Rate = 5.85 kW
Tot. Nom. LPG = 444 g/h
Voltage = 230 – 240 V ~
Frequency = 50/60 Hz
Pot. Nom. El. Rating = 1000 W
3 BURNERS WITH UR+
1 RAPID PLATE
LPG = 30 mbar
TOWN = 10 mbar
Tot. Nom. Gas Rate = 6.1 kW
Tot.Nom.H.K.Towngas Rate = 5.85 kW
Tot. Nom. LPG = 444 g/h
Voltage = 230 – 240 V ~
Frequency = 50/60 Hz
Pot. Nom. El. Rating = 1500 W
HONG KONG MARKET
4 BURNERS
LPG = 30 mbar
TOWN = 10 mbar
Tot. Nom. Gas Rate = 7.5 kW
Tot.Nom.H.K.Towngas Rate = 7.5 kW
Tot. Nom. LPG = 545 g/h
Voltage = 1.5 V DC
4 BURNERS WITH UR
LPG = 30 mbar
TOWN = 10 mbar
Tot.Nom.Gas Rate = 7.85 kW
Tot.Nom.H.K.Towngas Rate = 7.6 kW
Tot. Nom. LPG = 571 g/h
Voltage = 1.5 V DC
HONG KONG MARKET WITH BATTERY
Содержание 25658G-M