N°
DESCRIPTION
MJ/h
W
9
CONVERSIONS
BURNER ARRANGEMENT ON THE HOB
HEAT
INPUT
BURNERS
GAS
LARGE
Propane
2.75
9.00
90
11.2
3100
1
LEFT FRONT
Natural
1.00
9.00
150
11.2
3100
MEDIUM
Propane
2.75
9.00
90
10.2
2950
2
RIGHT REAR
Natural
1.00
9.00
145
10.2
2950
SMALL
Propane
2.75
9.00
60
4.9
1450
3
LEFT REAR
Natural
1.00
9.00
100
4.9
1450
AUXILIARY
Propane
2.75
1.00
50
4.0
1050
4
RIGHT FRONT
Natural
1.00
9.00
90
4.0
1050
FISH BURNER
Propane
2.75
9.00
83
9.2
2600
5
CENTER
Natural
1.00
9.00
136
9.2
2600
WOK BURNER
Propane
2.75
complete
102
14.0
4000
6
LEFT FRONT
Natural
1.00
complete
170
14.0
4000
TABLE
PRIMARY AIR
CLEARANCE “S”
(FIG. 19)
mm
DIAMETER
INJECTORS
1/00 mm
OPERATING
PRESSURE
kPa
Warning:
Conversion of this appliance shall only be
carried out only by authorised personnel.
11) REPLACEMENT OF INJECTORS
The burners are suitable for use with different gases.
To adjust to different gases it is necessary to change
the injectors.
A range of injectors are supplied with the appliance.
PROCEDURES
Removal of injectors
- Remove control panel (refer section 9).
- Loosen screw “A” and slide sleeve “B”, away from
control valve (refer figure 21).
- Loosen the injector with the ring spanner “M” (refer
figure 22).
- Unscrew the injector with the open ended spanner
until there is clearance for the spring hook “P”, to
engage the injector.
- Unscrew the injector completely.
Re-installation of injectors
- Select the correct injector.
- Hold injector with spring and offer it to the control
valve.
- Use spanner “M”, to engage the threads.
- Remove spring “P”.
- Tighten injector with ring spanner “M”.
The technical details of the operating pressures,
injector diameters and rating for various gases are
scheduled below.
FIG. 21