background image

HOT PLATES TECHNICAL DATA

11

FIG. 29

FIG. 30

PRESSURE

PROPANE

NATURAL

3 + 1 WOK BURNERS

“SOFT

3 + 1 WOK BURNERS

“RECTANGULAR

24658 G-m

4 BURNERS

(NO WOK)

“RECTANGULAR

2.75 kPa

1.00 kPa

2.75 kPa

1.00 kPa

2.75 kPa

1.00 kPa

TOT. HEAT INPUT

TOT.NOMINAL CONSUMP.

0.6 W

0.6 W

0.6 W

PROPANE

NATURAL

33.1 MJ/h

33.1 MJ/h

33.1 MJ/h

33.1 MJ/h

30.3 MJ/h

30.3 MJ/h

VOLTAGE

FREQUENCY

240 V ~

50 Hz

240 V ~

50 Hz

240 V ~

50 Hz

PRESSURE

PROPANE

NATURAL

4 + 1 WOK BURNERS

“RECTANGULAR

4 + 1 WOK BURNERS

“RECTANGULAR

24968 G-m

TOT. HEAT INPUT

TOT.NOMINAL CONSUMP.

PROPANE

NATURAL

42.3 MJ/h

42.3 MJ/h

49.5 MJ/h

49.5 MJ/h

VOLTAGE

FREQUENCY

240 V ~

240 V ~

50 Hz

50 Hz

2.75 kPa

1.00 kPa

2.75 kPa

1.00 kPa

0.6 W

0.6 W

Содержание 24658 G-m

Страница 1: ...is manufactured from the finest materials and components We would ask you to read the instructions within this booklet very carefully so as to enable you to obtain quality results from the outset The design of the figures contained in this handbook is purely indicative THE APPLIANCE MUST BE INSTALLED ONLY BY AUTHORISED PERSONNEL IN COMPLIANCE WITH THE INSTRUCTIONS PROVIDED THE MANUFACTUTER DECLINE...

Страница 2: ... 4 0 MJ 1050 W 5 Fish burner Center of 9 2 MJ 2600 W 6 Ultra rapid burner Left front of 14 0 MJ 4000 W 14 Right trivet 15 Center trivet 16 Left trivet 17 Trivet for ultra rapid burner 18 Eletric ignition push button 19 Burner control knob n 4 20 Burner control knob n 1 21 Burner control knob n 6 22 Burner control knob n 5 23 Burner control knob n 3 24 Burner control knob n 2 24658 G m 24968 G m ...

Страница 3: ...s established adjust burner to desired setting SWITCHING ON BURNERS EQUIPPED WITH FLAME FAILURE DEVICE FIG 1 The knobs of burners equipped with flame failure device must be turned in an anticlockwise direction until they reach the Full on position large flame fig 1 and come to a stop Now depress the knob in question and repeat the previously indicated operations Keep the knob depressed for about 1...

Страница 4: ...NCE LOCATE PAN CENTRALLY OVER THE BURNER SO THAT IS STABLE AND DOES NOT OVERHANG THE APPLIANCE FIG 3 USE ONLY A WOK SUPPORT SUPPLIED OR RECOMMENDED BY THE MANUFACTURER OF THE APPLIANCE FIG 4 THE APPLIANCE IS NOT INTENDED FOR USE BY YOUNG CHILDREN OR INFIRM PERSONS WITHOUT SUPERVISION YOUNG CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE APPLIANCE DO NOT STORE OR USE GASOLINE...

Страница 5: ...lled parts it is necessary that they be cleaned frequently with warm soapy water Do not clean them while they are hot and never use abrasive powders or cleaners Stains may be removed by wiping with a clean cloth and soapy water before stains become cold Stubborn stains may be removed by soaking in hot soapy water Do not allow vinegar coffee milk salty water lemon or tomato juice to remain in conta...

Страница 6: ... ARE A SOURCE OF POTENTIAL DANGER 6 FIXING OF THE HOTPLATE The hotplate is provided with a special seal to prevent liquid penetrating to the underside of the appliance For correct installation of this seal ensure the procedures detailed below are followed Unpack the sealing strips ensuring that the transparent protection is not damaged and remains attached to the seal Invert the appliance and fix ...

Страница 7: ...ulation at the appliance is not required To connect supply to the appliance use transition pieces as shown in figure 13 These pieces are supplied with the appliance on purchase 8 ELECTRICAL CONNECTION The appliance is supplied with a 1800 mm long flexible supply lead The point of attachment for this lead is located at the rear and on the underside of the appliance 380 mm from the right hand side T...

Страница 8: ...htened 10 CONTROL VALVES Reduced rate adjustment The control valves are suitable for all types of gases They are the male cone type allowing one direction of flow Simmer flame adjustment refer figure 20 Light burner and set to low setting Remove control knob friction fit Insert a small screwdriver into the hollow stem of the valve and adjust the flame to the desired level Ensure that flame is stab...

Страница 9: ... carried out only by authorised personnel 11 REPLACEMENT OF INJECTORS The burners are suitable for use with different gases To adjust to different gases it is necessary to change the injectors A range of injectors are supplied with the appliance PROCEDURES Removal of injectors Remove control panel refer section 9 Loosen screw A and slide sleeve B away from control valve refer figure 21 Loosen the ...

Страница 10: ...s on the under body Push the hotplate to the left lower and secure the screws refer figure 25 Replacement of electric cable Should the flexible supply lead need replacement it is essential that one of the correct rating and construction be used The lead must contain an earth and this must be connected Burner replacement refer figure 26 Disassemble the appliance as detailed above Remove screws R an...

Страница 11: ...MINAL CONSUMP 0 6 W 0 6 W 0 6 W PROPANE NATURAL 33 1 MJ h 33 1 MJ h 33 1 MJ h 33 1 MJ h 30 3 MJ h 30 3 MJ h VOLTAGE FREQUENCY 240 V 50 Hz 240 V 50 Hz 240 V 50 Hz PRESSURE PROPANE NATURAL 4 1 WOK BURNERS RECTANGULAR 4 1 WOK BURNERS RECTANGULAR 24968 G m TOT HEAT INPUT TOT NOMINAL CONSUMP PROPANE NATURAL 42 3 MJ h 42 3 MJ h 49 5 MJ h 49 5 MJ h VOLTAGE FREQUENCY 240 V 240 V 50 Hz 50 Hz 2 75 kPa 1 00 ...

Страница 12: ...ydney Office 97 Rose Street CHIPPENDALE NSW 2008 Tel 02 9380 8444 Brisbane Office Unit 2 44 Leonard Street WOOLLOONGABBA QLD 4102 Tel 07 3891 2499 Fax 07 3891 2495 Adelaide Office 106A Rundle Street KENT TOWN SA 5067 Tel 08 8132 1600 Fax 08 8132 1655 For Service Phone 1300 650 020 in Australia Spare Parts Tel 03 9569 7744 www andico com au ...

Отзывы: