49
A) Ramp with ending nut
B) Seal
C) Adjustable connection
Fig. 4
Gas Connection
Choose fixed connections or use a flexible pipe in stainless steel.
If using flexible metallic pipes, be careful they do not come in contact with mobile parts or they are not
squeezed. Use the same attention when the hob is combinated with an oven.
IMPORTANT -
To ensure a correct operation, a saving
of energy and the long-life of the appliance, the voltage
pressure of the appliance must correspond to the
recommended values.
The adjustable connection is fixed to the comprehensive
ramp by means of a threaded nut G 1/2".
Interpose the sealing between the components as shown
in Fig. 4.
Screw the parts without forcing, adjust the connection in
the required direction and tighten everything.
IMPORTANT
- When the final connection has been
made, it is essential that a thorough leak test is carried out
on the hob and installation. Use some soapy water,
never a flame.
Technical data
Overall dimensions
680 x 510
Cut out dimensions
560 x 480
Category
II2H3+
Appliance Class
3
Gas connection
G 1/2"
Gas supply
Natural gas G20 - 20 mbar
Electric supply
230 V ~ 50 Hz