background image

 

 

SOLED_IM_ITA-ENG  - Rev.07 of 19/07/18 

Page 4 of 4 

SOLED 

Made in Italy 

ISTRUZIONI DI MONTAGGIO E 

MANUTENZIONE 

MOUNTING AND MAINTENANCE 

INSTRUCTION

 

 

ATTENTION 

 

 

 

a) 

 

 

 

b) 

a) 

Replace any cracked protective shield. 

b) 

During maintenance, do not stare at the operating light source. 

c)  Class  II  luminaires  must  be  installed  in  such  a  way  that  it  is  impossible  for  any  exposed  metal  part  to  come  in  contact  with  electrical 

components. 

d)  Use only devices with supplementary insulation between 1-10V/DALI terminals and mains terminals. 
e)  The  device  has developed  in  compliance  with  the  current  standards;  it  is  necessary  that  the  installation  is  done  properly,  according  with  the 

instructions supplied. 

f)  The  present  instruction  paper  has  to  be  kept  for  any  future  maintenance  operation  on  the  luminaire.  Non-compliance  with  the  above  will 

automatically release AEC Illuminazione Srl from any responsibility. 

F1 (optional) 

Protection earth 
(only class I) 

 

LED 

modules 

CN2 

 

PSU 

ELECTRIC SCHEME 

CN1 

 

SPD 

F1 (optional) 

 

LED 

modules 

CN2 

 

PSU 

ELECTRIC SCHEME WITH PLM 

Fuse 250Vac 10A (suggested size) 

SPD 

Surge protection device 

CN 

Connector 

PSU 

LED power supply 

Terminal 

CD 

Control device 

 

 

CD 

CN1 

 

SPD 

Protection earth 
(only class I) 

SOLED luminaire is classified under 

EXEMPT GROUP

” according to 

photobiologycal safety standard 

IEC/EN 62471

 

NO RISK  

for the operators and end users. 

This  symbol  on  the  product  or  in  its  packaging  is  based  on  WEEE 
Directive (Directive on Waste Electrical and Electronic Equipment), which 
is a regulation in EU member countries, and this symbol indicates that this 
product shall not be treated as household waste. 
To reduce the environmental impact and minimize the volume of landfills, 
please cooperate in reuse and recycle. 
For  how  to  dispose  of  the  product,  please  contact  your  dealer  or  the 
nearest AEC Illuminazione sales office. 

INFORMATION TO THE CUSTOMERS 

 

Disposal  of  Old  Electrical  &  Electronic  Equipment 
(Applicable  in  the  European  Union  and  other 
European  countries  with  separate  collection 
system) 

In  order  to  insure  double 
insulation characteristic of the 
feeder 

cable, 

we 

would 

advise  that  you  first  secure 
the  feeder  cable  to  the 
internal  cable  clamp,  remove 
approximately 

20mm 

of 

external  sheathing,  and  6-
7mm  of  sheathing  from  the 
internal wires. 

ELECTRICAL LINE CONNECTION 

<   2 0 mm 

6

7 mm 

 

Area exposed 

Side area 

0.07 m

2

 

Base area 

0.25 m

2

 

Form factor: 1.2 

Max height of installation: 8m 

 

Содержание Annell Soled

Страница 1: ...ssima dei conduttori di 2 5mm 2 Bloccare in posizione il cavo di alimentazione stringendolo al fermacavo in ingresso F Fig 4 In caso l apparecchio sia equipaggiato con dispositivo PLM annotarsi il serial number dell apparecchio Orientare correttamente l apparecchio vedere Fig 6 e fissarlo con i 4 grani del testa palo Per stringere i grani utilizzare una chiave a brugola di 4mm applicando un moment...

Страница 2: ...o sui loro imballaggi indica che questo prodotto non deve essere trattato come un rifiuto domestico Per ridurre l impatto ambientale delle apparecchiature elettriche ed elettroniche di rifiuto WEEE Waste Electrical and Electronic Equipment e per minimizzare il volume dei WEEE che entra nelle discariche si prega di procedere al riutilizzo e al riciclaggio Per ulteriori informazioni mettersi in cont...

Страница 3: ...al diameter between 7mm and 13mm with maximum section of 2 5mm 2 Block in position the mains cable tightening it to the cable holder E Pic 4 In case the luminaire is equipped with PLM annotate the serial number of the control device Orientate correctly the luminaire see Pic 6 and block it to the pole with the 4 grub screws L Pic 3 Tighten the grub screws using a set screw wrench of 4mm applying a ...

Страница 4: ...evice CN Connector PSU LED power supply M Terminal CD Control device CD CN1 SPD Protection earth only class I SOLED luminaire is classified under EXEMPT GROUP according to photobiologycal safety standard IEC EN 62471 NO RISK for the operators and end users This symbol on the product or in its packaging is based on WEEE Directive Directive on Waste Electrical and Electronic Equipment which is a reg...

Отзывы: