SOLED_IM_ITA-ENG - Rev.07 of 19/07/18
Page 4 of 4
SOLED
Made in Italy
ISTRUZIONI DI MONTAGGIO E
MANUTENZIONE
MOUNTING AND MAINTENANCE
INSTRUCTION
ATTENTION
a)
b)
a)
Replace any cracked protective shield.
b)
During maintenance, do not stare at the operating light source.
c) Class II luminaires must be installed in such a way that it is impossible for any exposed metal part to come in contact with electrical
components.
d) Use only devices with supplementary insulation between 1-10V/DALI terminals and mains terminals.
e) The device has developed in compliance with the current standards; it is necessary that the installation is done properly, according with the
instructions supplied.
f) The present instruction paper has to be kept for any future maintenance operation on the luminaire. Non-compliance with the above will
automatically release AEC Illuminazione Srl from any responsibility.
F1 (optional)
Protection earth
(only class I)
L
N
LED
modules
CN2
PSU
ELECTRIC SCHEME
CN1
SPD
F1 (optional)
L
N
LED
modules
CN2
PSU
ELECTRIC SCHEME WITH PLM
F
Fuse 250Vac 10A (suggested size)
SPD
Surge protection device
CN
Connector
PSU
LED power supply
M
Terminal
CD
Control device
CD
CN1
SPD
Protection earth
(only class I)
SOLED luminaire is classified under
“
EXEMPT GROUP
” according to
photobiologycal safety standard
IEC/EN 62471
.
NO RISK
for the operators and end users.
This symbol on the product or in its packaging is based on WEEE
Directive (Directive on Waste Electrical and Electronic Equipment), which
is a regulation in EU member countries, and this symbol indicates that this
product shall not be treated as household waste.
To reduce the environmental impact and minimize the volume of landfills,
please cooperate in reuse and recycle.
For how to dispose of the product, please contact your dealer or the
nearest AEC Illuminazione sales office.
INFORMATION TO THE CUSTOMERS
Disposal of Old Electrical & Electronic Equipment
(Applicable in the European Union and other
European countries with separate collection
system)
In order to insure double
insulation characteristic of the
feeder
cable,
we
would
advise that you first secure
the feeder cable to the
internal cable clamp, remove
approximately
20mm
of
external sheathing, and 6-
7mm of sheathing from the
internal wires.
ELECTRICAL LINE CONNECTION
< 2 0 mm
6
7 mm
Area exposed
Side area
0.07 m
2
Base area
0.25 m
2
Form factor: 1.2
Max height of installation: 8m