Ta = 30°C
Cosmopolis White
MHL
SHP
White Son
60W
140W
70W
100W
150W
250W
70W
100W
150W
250W
50W
100W
Optic
Optic
Optic
Optic
Optic
Optic
Optic
Optic
Optic
Optic
Optic
Optic
E27
OC
NO OP
NO OP
E27
OC
OC
E40
NO OP
NO OP
AS
NO OP
NO OP
AS
FC2
NO OC
NO OC
G12
OC
NO OP
AS
G22
AS
GX12
OC
PG12-1
OC
NO OP
PG12-2
OC
PGX12-2
NO OP
PGZ12
OC
NO OP
RX7S
OC
OC
RX7S-24
OPTIC
LAMP
HOLDER
LAMP
POS
AS45 / AS65
E27
100W MHL-E
B
AS45 / AS65
E27
150W MHL-E
B
AS45 / AS65
E40
100W MHL-T
C
AS45 / AS65
E40
150W MHL-T
C
AS45 / AS65
E40
250W MHL-T
E*
AS45 / AS65
E40
250W MHL-T
D**
AS45 / AS65
E40
100W SHP-T
C
AS45 / AS65
E40
150W SHP-T
C
AS45 / AS65
E40
250W SHP-T
E
AS45 / AS65
FC2
250W MHL
2A
AS45 / AS65
FC2
250W SHP
2B
AS45 / AS65
G12
150W MHL
B+spacer
AS45 / AS65
G12
250W MHL
B+spacer
AS45 / AS65
G22
250W MHL
B
AS45 / AS65
PG12-1
100W SHP-White
A
AS45 / AS65
PGX12-2
150W MHL
A
AS45 / AS65
RX7S
150W MHL
1A
AS45 / AS65
RX7S-24
150W MHL
1A
AS45 / AS65
RX7S-24
150W SHP
1A
AS45 / AS65
PGZ12
140 CPO
A
OC
E27
70W MHL-T
B
OC
E27
70W MHL-E
C
OC
E27
100W MHL-E
C
OC
E27
150W MHL-E
C
OC
E27
70W SHP-T
B
OC
E40
100W MHL-T
A
OC
E40
150W MHL-T
A
OC
E40
100W SHP-T
A
OC
E40
150W SHP-T
A
OC
G12
70W MHL
B
rot+spacer
OC
G12
150W MHL
B
rot+spacer
OC
PG12-1
100W SHP-White
C
OC
PG12-2
70W MHL
C
OC
PGX12-2
150W MHL
C
OC
RX7S
70W MHL
DA Plate
OC
RX7S
150W MHL
DA Plate
OC
RX7S
70W SHP
DA Plate
OC
RX7S-24
150W MHL
DA Plate
OC
RX7S-24
150W SHP
DA Plate
OC
PGZ12
60W CPO
E
OC
PGZ12
140W CPO
D
OP
FC2
250W MHL
OP
FC2
250W SHP
OP
RX7S
150W MHL
OP
RX7S-24
150W MHL
OP
RX7S-24
150W SHP
AS45/AS65
Lamp holder support
Lamp holder plate
AS45/AS65 double
attachment
Lamp holder plate
OP
Lamp holder plate
150W
Lamp holder plate
250W
ATTENTION
a)
The luminaire can be installed close to flammable surfaces.
b)
High voltage danger with RX7 and FC2 lamp holder
c)
Class II luminaires must be installed in such a way that it is impossible for any exposed metal part to come in contact with electrical components.
d)
Luminaires for Metal Halide lamps must be always complete with its protective screen.
e)
For luminaires with Metal Halide lamps, damaged protective shields can only be replaced with original AEC Illuminazione’s replacement shields.
f)
On luminaires for Metal Halide lamps use only UV Stop protected lamps.
g)
This luminaire has been designed and manufactured following all relevant standards. The installation must be done by experienced personnel and
following the instructions.
The present instruction paper has to be kept for any future maintenance operation on the luminaire.
Non compliance with the above will automatically release AEC Illuminazione Srl from any responsibility.
*: lamp with ceramic burner
**: lamp with quartzitic burner
OC Optic
NORMAL position
ROTATED position
OC
Lamp holder plate
OC double attachment
Lamp holder plate D.A.