MOUNTING AND MAINTENANCE
INSTRUCTION
LOGIKA 2 AS-OC-OP_IM_ENG - Rev.09 of 16/09/16
Pag. 2 of 3
AS - OC - OP
Made in Italy
Post top mounting with MT bracket
Dimensions
Mounting
Mount the fixing support of LOGIKA 2 to the pole through the four 8MA x 100 (A) screws. Tighten the four screws with a set
screw wrench of 6mm applying a twisting moment of 10Nm. Tighten the two screws 8MA x 14 with a set screw wrench of 5mm
applying a twisting moment of 10Nm to fix the fitting in horizontal position (B). See the MT mounting instruction for others
details.
B
A
B
Wall mounting
Dimensions
Mounting
Fix the LOGIKA 2 support to the plate trough the four 8MA x 100 screws (A). Tighten the four screws with a set screw wrench of
6mm applying a twisting moment of 10Nm. Tighten the two 8MA x 14 screws with a set screw wrench of 5mm applying a
twisting moment of 10Nm to fix the fitting in horizontal position (B). See the plate mounting instruction for others details.
A
B
Bracket mounting (MH - MI - MD)
Dimensions
Mounting
Put the LOGIKA 2 in position and fix it trough the 8MA x 14 screws (A). Tighten the screws with a set screw wrench of 5mm
applying a twisting moment of 10Nm (A). See the brackets mounting instruction for others details.
A
A
A