ENSA Standard LED Batten - Use & Installation Guide
Applicable Models: LEDBT18WS2, LEDBT36WS2, LEDBT18WSE, LEDBT36WSE
For full product information, visit www.ensalife.com
1. Installation Instructions
2. Installation Procedure
Please read these instructions carefully before
installation and keep for future reference.
• Always turn off supplied power to the LED batten
before performing installation or maintenance.
• This LED batten must be earthed.
• This LED batten is complete without a ballast.
• Drilling into the batten body will void the
warranty - this batten should only be mounted
by surface mounting clips.
• Installation and wiring must only be performed
by a qualified, licensed electrician.
• Please ensure rated voltage and frequency of the
batten is compatible with the power supply.
• Clean with soft cotton cloth only, do not use any
chemical solvents when cleaning this batten.
• In case of fitting failure, switch off power to the
batten and wait for the fitting to cool. Perform
steps
2.3 - 2.8 in reverse to take down the fitting.
The mounting centre points for the LED batten are
located on the included mounting clips. Choose
a suitable location and fix the clips using included
wall plugs & screws.
Before fitting the batten to the mounting clips,
ensure lock toggles are attached to the body.
Secure the array board with rotating locking clips.
Fit the cover to the body, close all lock toggles to
complete installation.
Switch on main power to test.
Please keep these instructions in a safe place for
future reference.
Insert main power supply through the gland then
tighten the lock nut to the batten body. Make sure
there is sufficient cable to reach the terminal block.
Attach the safety cable to stop the array board from
falling; enables hands free use.
Mounting clips span can be slightly adjusted to fit
to different installation tolerances. The light can also
be wall mounted.
2.1 Mounting Clips
2.4 Lock Toggles
2.8 Secure Array Board & Close Cover
2.9 Test & Complete
2.5 Running Power Cable
2.6 Array Board Safety Cable
2.3 Ceiling or Wall Mounting
See table and matching diagram below for
mounting information
Model
Length (A) Fix Span (B) Clips
LEDBT18WS2
655mm
470mm
4
LEDBT36WS2
1260mm
900mm
8
LEDBT18WSE
655mm
470mm
4
LEDBT36WSE
1260mm
900mm
8
1.1 Important Notes
1.2 Installation Specifications
Centre points (refer 1.2 table)
1
1
2
2
Connect as illustrated, ensuring the cable is secure
with no bare wires and correct polarity.
2.7 Connect Supply to Terminal Blocks