7224 & 7226 OPERATOR’S MANUAL –
SECTION 5
•
Compensation setting to select RC network
when operating in Controlled Current mode.
•
Stop Mode/Run Mode setting for selection of
power-up state.
•
Standby mode on Over Load setting to trig
-
ger Standby mode when amplifier senses an
Overload state.
Figure 5.2 – Main Board Location Inside
Access Panel
Figure 5.3 – Master/Slave Setting
Figure 5.4 – Gain Trim Control
5.2.2 Fixed Gain/Variable Gain Setting
The 7224/7226 amplifier ships with an enabled
Gain Control knob (located on the amplifier front
panel). To disable the
Variable Gain
control and
set for a
Fixed Gain of 20,
locate and unplug
the red connector from jumper
J10.
Then place a
jumper on the left two pins
at that location. See
Figure 5.4.
5.2.1 Master/Slave Setting
To enable the amplifier for use as a single amplifier
or as the Master amplifier in a multi-amplifier
system, set jumpers
P1
and
P2
in the
Master
posi-
tion (jumpers across top two pins of each set). The
Master setting is the factory default. To enable the
amplifier for use as a Slave amplifier in a multi-
amplifier system, set jumpers
P1
and
P2
in the
Slave
position (jumpers across bottom two pins of
each set). See
Figure 5.3.
For complete information on multi-amp system
configuration and wiring, please consult the
AE
Techron Multi-Amp Configuration Guide
avail-
able for download from the AE Techron website at
www.aetechron.com.