Digital I/O
Digital In

2 Digital Input
Dry Contact

   

Logic level 0 : Open

   

Logic level 1 : Close

Wet Contect

Logic level 0: +3V max

   

Logic level 1: +10VDC to 30VDC

Digital Out

2 Digital Output

    

Open Collect to 30V

 200mA 

max 

Load 

Power Dissipation 450mW

Environment

•  Operating Temperature

0 ~ 70° C (32° ~ 158° F)

•  Storage Temperature

-20° ~ 80° C (-4° ~ 176° F)

•  Operating Humidity

20 ~ 95% (non-condensing)

•  Storage Humidity

0 ~ 95% (non-condensing)

Содержание UNO-1019

Страница 1: ...UNO 1019 PXA 200MHZ 64MBRAM 2xLAN 4xCOM Universal Network Controller User Manual...

Страница 2: ...any means without the prior written permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reli able However Advantech Co Ltd assumes no responsibility for i...

Страница 3: ...lacement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem enc...

Страница 4: ...t installed and used in accordance with the instruction manual may cause harmful interference to radio communications Opera tion of this equipment in a residential area is likely to cause harmful inte...

Страница 5: ...pment to the power outlet 9 Position the power cord so that people cannot step on it Do not place anything over the power cord 10 All cautions and warnings on the equipment should be noted 11 If the e...

Страница 6: ...ition according to IEC 704 1 1982 is no more than 70 dB A DISCLAIMER This set of instructions is given according to IEC 704 1 Advantech disclaims all responsibility for the accuracy of any statements...

Страница 7: ...1 Figure 2 3 COM3 4 Terminal Resistors JP8 10 11 2 5 Power Connections 13 Figure 2 4 Power Pin Assignments 13 2 6 Digital Input Output 14 Figure 2 5 Digital I O Pin Assignments 14 Figure 2 6 Digital I...

Страница 8: ...Development Procedure 55 4 5 1 Application Development Procedure 55 4 5 2 Watchdog Timer 57 4 5 3 DIO LED and Buzzer 63 4 6 Saving Your Settings 72 4 7 UNO 1019 Network Administration User Guide 72 4...

Страница 9: ...ew This chapter gives background infor mation on the UNO 1019 It shows you the UNO 1019 overview and specifica tions Sections include Introduction Features Hardware Specifications Safety Precautions C...

Страница 10: ...With these advantage UNO 1019 is suitable for communication gateway for converting communication protocol IO control and data storage UNO 1019 is a perfect embedded ready platform that can shorten yo...

Страница 11: ...ale PXA255 200 MHz Memory 64 MB SDRAM Indicators Power Serial Tx Rx User Define 3 Led Storage Onboard 16 MB Flash memory SSD 1 x internal type I II CompactFlash slot Others Real Time Clock Watch Dog T...

Страница 12: ...Wet Contect Logic level 0 3V max Logic level 1 10VDC to 30VDC Digital Out 2 Digital Output Open Collect to 30V 200mA max Load Power Dissipation 450mW Environment Operating Temperature 0 70 C 32 158 F...

Страница 13: ...5 Chapter 1 1 4 Chassis Dimensions Figure 1 1 UNO 1019 Top View Dimensions Figure 1 2 UNO 1019 Side View Dimensions...

Страница 14: ...UNO 1019 User Manual 6 Figure 1 3 UNO 1019 Front View Dimensions Figure 1 4 UNO 1019 Bottom View Dimensions...

Страница 15: ...In this chapter you will be given an overview of the UNO 1019 hardware installation procedures Sections include Overview LED Network Connections Serial Connections Power Connections Digital Input Outp...

Страница 16: ...UNO 1019 User Manual 8 Chapter 2 Installation 2 1 Overview Figure 2 1 UNO 1019 Overview Item Description 1 Serial Port 2 Networking port 3 LED 4 CompactFlash slot 5 Power 6 Digital input output...

Страница 17: ...nel shows link green and network speed yellow Table 2 1 UNO 1019 LED Definitions LED Color Status Description PWR RED On System power is on Off System power is off D1 D3 Green User programmable Serial...

Страница 18: ...OM1 COM2 provide RS 232 and COM3 COM4 provide RS 232 422 485 The default settings of COM3 COM4 is RS 422 485 and the UNO 1019 could identify RS 422 or RS 485 automatically according to your wiring If...

Страница 19: ...rminal Resistor You can install terminator resistors if necessary to match impedance Each signal line Tx Tx Rx Rx Data Data Especially in fields with electric noise installing terminal resistors is he...

Страница 20: ...UNO 1019 User Manual 12 Refer to the figure and table below for COM1 COM2 descriptions COM1 COM2 Pin Assignments Pin RS 232 1 DCD 2 RxD 3 TxD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 RI...

Страница 21: ...2 5 Power Connections UNO 1019 supports 10 30 VDC power inputs A detailed power pin image is shown below Figure 2 4 Power Pin Assignments COM3 COM4 Pin Assignments Pin RS 232 RS 422 RS 485 1 DCD TxD D...

Страница 22: ...tal inputs and outputs for UNO 1019 Figure 2 5 Digital I O Pin Assignments You can refer to Figures 2 6 2 7 for the digital input connection UNO 1019 provides 2 ways to use digital inputs function ple...

Страница 23: ...15 Chapter 2 Figure 2 6 Digital Input Connection Dry Contact Figure 2 7 Digital Input Connection Wet Contact...

Страница 24: ...high Figure 2 8 Digital Output Connections Wet Contact 2 7 CompactFlash The procedure for installing a CompactFlash card into the UNO 1019 is detailed below please follow these steps carefully 1 Make...

Страница 25: ...ent mounting methods Panel DIN rail 2 8 1 Panel Mounting UNO 1019 can be wall mounted by using the included mounting kit First use the screws included in the package to combine the UNO 1019 and metal...

Страница 26: ...UNO 1019 User Manual 18 Then screw the whole device to the wall Figure 2 10 Attach UNO 1019 to the Wall...

Страница 27: ...19 Chapter 2 2 8 2 DIN rail Mounting You can also mount UNO 1019 on a standard DIN rail by below steps First pull down the kit in the back of UNO 1019 Figure 2 11 Installation to DIN rail Step 1...

Страница 28: ...UNO 1019 User Manual 20 Then hang the UNO 1019 to the DIN rail with angle of inclination Figure 2 12 Installation to DIN rail Step 2...

Страница 29: ...UNO 1019 at a right angle with the Din rail The grounding spring in the back should be flush with the aluminum rail Then pull up the kit to wedge the UNO 1019 firmly into place Figure 2 13 Installatio...

Страница 30: ...UNO 1019 User Manual 22...

Страница 31: ...2 CHAPTER 3 Initial Setup This chapter shows how to initialize the UNO 1019 sections include Sections include Initial Procedure Configure UNO 1019...

Страница 32: ...IP Default setting LAN1 is 10 0 0 1 LAN2 is 10 0 0 2 3 The UNO 1019 default IP is set as 10 0 0 1 Please set the IP of your host computer to be static IP 10 0 0 XXX for connection with UNO 1019 4 Usi...

Страница 33: ...using a crossover Ethernet cable Or connect both UNO 1019 and your computer into a hub After UNO 1019 boot up it will broadcast it s IP to the network uScope Remote Display tool running on you compute...

Страница 34: ...UNO 1019 User Manual 26 Choose the connected device in the list After clicking Connect bottom the configuration computer will con nect with UNO 1019 The remote display screen will be as following...

Страница 35: ...27 Chapter 3 Please go to the Command Prompt for network IP setting User can use ipchange command for IP change setting in command prompt mode Please type ipchange for command reference...

Страница 36: ...nual 28 If LAN1 of UNO 1019 will be set as DHCP the ipchange 1 1 will be used as set up command If LAN2 of the UNO 1019 will be set as the specific IP address the setting command and procedure should...

Страница 37: ...Done to make sure the IP change setting work is successfully done Power on the UNO 1019 module again to reboot the WinCE for new IP address implement Note The uScope Remote Display tool is only used...

Страница 38: ...UNO 1019 User Manual 30...

Страница 39: ...led explanations of the UNO 1019 s Advanced Applications Sections include Inserting a CompactFlash Card ActiveSync Connection Remote Access Configuration Autorun Configuration Application Development...

Страница 40: ...Sync help for details Note How to update the WinCE NET 4 2 Image for UNO 1019 Please follow the above steps to plug in the CF card with image the image file is put in the path UNO 1019 Image of UNO 10...

Страница 41: ...Insert UNO 1019 CD into the configuration computer 2 Install UNO 1019 Software Development Kit for eVC from below path UNO 1019 SDK 3 Install Microsoft ActiveSync 4 1 from below path ActiveSync 4 Plea...

Страница 42: ...UNO 1019 User Manual 34 1 Click the icon Make New Connection Select the connection type Direct Connection then press Next...

Страница 43: ...r 4 2 Choose the COM port of UNO 1019 3 Press Start Settings Control Panel and then PC Connection 4 Click Change button to choose your network communication In this example change the network to My Co...

Страница 44: ...UNO 1019 User Manual 36 Step 4 Setting Up the Communication Environment of the Host 1 Double click the icon ActiveSync 2 Select File Connection Settings...

Страница 45: ...37 Chapter 4 3 Configure the connection settings as below 4 After you configure the connection setting it will show the below dialog window when you press Get Connected...

Страница 46: ...UNO 1019 User Manual 38 5 Press Start Run of UNO 1019 enter the windows repllog exe in the command line of and press OK button Note Don t click Next button at this time...

Страница 47: ...s the Next button in the Get Connected dialog in the host It will build the connection between UNO 1019 and host 7 If the connection between UNO 1019 and the host has been established you will see bel...

Страница 48: ...If the connection between UNO 1019 and the host has been established you will see below message in the host Select No then press Next button After the New partnership setting it will show the below d...

Страница 49: ...n in Microsoft ActiveSync window it will pop up the Mobile Device window to display the file resources and information of UNO 1019 as below For example if you click the icon My Documents you will see...

Страница 50: ...tion 4 3 Remote Access Server Configuration UNO 1019 provides Remote Access Services which offers the possibil ities for remote network and user to have TCP IP access local mail serv ers access to dat...

Страница 51: ...Configuration 1 Press start of task bar of window system and select Settings Networking and Dial up Connections 2 Double click Make New Connection then a dialog window will pop out Select Dial Up Conn...

Страница 52: ...UNO 1019 User Manual 44 3 Setup the device according to the specification of the modem and press Next...

Страница 53: ...figuration 4 Press start of task bar of window system and select Setting Networking and Dial up connections Double click the new con nection that you made previously it is RAS Connection in this case...

Страница 54: ...ing Patterns button in the Dialing Properties window Edit the dialing pattern for each type of call to change how the phone is dialed Note Country Region Code please enter E or e Area Code please ente...

Страница 55: ...47 Chapter 4 6 Double click My Connection and press Connection button to build a PPP connection Dial in Configuration 1 Press start of task bar of window system and select Setting Control Panel...

Страница 56: ...al 48 2 Double click the RAS Server icon from Control Panel 3 Select the General tab under Advantech RAS Server Configura tion Select Enable RAS Use Static IP Address and enter a specified IP in Stati...

Страница 57: ...tab under Advantech RAS Server Config uration Click Add button to setup the input line according to the available RAS device 5 Select the Logon Security tab under Advantech RAS Server Configuration S...

Страница 58: ...Add a new account for remote access services 7 After all settings are completed press Apply button and then it will pop up the RasConfig dialog window Press Yes button to save reg istry setting to sto...

Страница 59: ...guration Note This document introduces how to execute applications automatically when you boot UNO 1019 up Autorun Configuration Procedure 1 Execute the UNO Configuration Utility 2 Go to the Misc page...

Страница 60: ...UNO 1019 User Manual 52...

Страница 61: ...53 Chapter 4 3 Click on the Program Path bottom for selecting the program for Auto Run setting Please choose the program then press OK...

Страница 62: ...User Manual 54 4 Click on the Add bottom to set the program for Auto Run action The UNO Configuration Utility will add the selected program in Auto Run requirement Please press OK to finish the confi...

Страница 63: ...capabilities such as C exception handling Run Time Type Information RTTI and a plethora of new debugger functionalities Before you begin to develop your application you must install Microsoft eMbedded...

Страница 64: ...UNO 1019 User Manual 56 8 Select UNO 1019 in the main window of Visual C...

Страница 65: ...n the program will be executed in UNO 1019 4 5 2 Watchdog Timer There is a built in watchdog timer in UNO 1019 Users can utilize the WDT driver with standard WIN32 API to implement the watchdog func t...

Страница 66: ...pInBuffer unused nInBufferSize unused lpOutBuffer unused nOutBufferSize unused 2 IOCTL _WDT_DISABLE Disable the Watchdog time on your application lpInBuffer unsed nInBufferSize unused lpOutBuffer unus...

Страница 67: ...the Watchdog timeout value lpInBuffer The DWORD pointer to your Watchdog timeout setting The Watchdog timeout setting is just a number 0 means 2 seconds 1 means 5 seconds 2 means 10 seconds 3 means 1...

Страница 68: ...e operation This value identifies the specific operation to be performed and the type of device on which the operation is to be performed No specific values are defined for the dwIo ControlCode parame...

Страница 69: ...function makes use of the variable pointed to bylpBytesReturned After such an opera tion the value of the variable is without meaning lpOverlapped in Ignored set to NULL Return Values Nonzero indicate...

Страница 70: ..._WRITE 0 NULL OPEN_EXISTING FILE_ATTRIBUTE_NORMAL NULL if m_hWDT INVALID_HANDLE_VALUE DebugMsg CString WDT driver fail return DWORD dwTemp DWORD nIndex 2 Set the Watchdog Timer as 10 seconds Number 2...

Страница 71: ...ese resources via the built in Advantech IO Service driver named ADV1 The follows are the descriptions and examples of the usable DeviceIoControl codes in this driver How to Use the Control Code There...

Страница 72: ...sed 3 ADV_IOCTL_READ_DO Read the written Digital Output value lpInBuffer unsed nInBufferSize unsed lpOutBuffer The BYTE pointer to the current DO value BIT0 indicates DO_0 state BIT1 indicates DO_1 st...

Страница 73: ...URN_OFF_LED2 Turn LED2 off lpInBuffer unused nInBufferSize unused lpOutBuffer unused nOutBufferSize unused 8 ADV_IOCTL_TURN_ON_LED3 Turn LED3 on lpInBuffer unused nInBufferSize unused lpOutBuffer unus...

Страница 74: ...p the buzzer that is playing lpInBuffer unused nInBufferSize unused lpOutBuffer unused nOutBufferSize unused DeviceIOControl This function sends a control code directly to a specified device driver ca...

Страница 75: ...operation This parameter can be NULL if the dwIoControlCode parame ter specifies an operation that does not require input data nInBufferSize in Size in bytes of the buffer pointed to by lpInBuffer lpO...

Страница 76: ...define ADV_IOCTL_TURN_ON_LED1 CTL_CODE FILE_DEVICE_UNKNOWN 0x930 METHOD_BUFFERED FILE_ANY_ACCESS define ADV_IOCTL_TURN_OFF_LED1 CTL_CODE FILE_DEVICE_UNKNOWN 0x931 METHOD_BUFFERED FILE_ANY_ACCESS defi...

Страница 77: ...WORD i dwGot dwNumReturned LED IO Test Program hDev CreateFile _T ADV1 Pointer to the name of the port GENERIC_READ GENERIC_WRITE Access read write mode 0 Share mode NULL Pointer to the security attri...

Страница 78: ...printf Set Dout_0 low Set Dout_1 low r n if DeviceIoControl hDev ADV_IOCTL_WRITE_DO dwGot 4 NULL 0 dwNumReturned NULL printf ADV_IOCTL_WRITE_DO failed exit r n break if DeviceIoControl hDev ADV_IOCTL...

Страница 79: ...ADV_IOCTL_TURN_OFF_LED1 NULL 0 NULL 0 NULL NULL if dwGot 0x02 DeviceIoControl hDev ADV_IOCTL_TURN_ON_LED2 NULL 0 NULL 0 NULL NULL else DeviceIoControl hDev ADV_IOCTL_TURN_OFF_LED2 NULL 0 NULL 0 NULL...

Страница 80: ...e Registry to CF card and it will display message to notify you whether the Registry has been successfully saved 4 7 UNO 1019 Network Administration User Guide Advantech s UNO 1019 series is a built i...

Страница 81: ...site UNO 1019 s network setting remotely 1 Execute standard browser for instance Internet Explorer and enter UNO 1019 which you would like to connect s IP address as below IP address networkadmin Inst...

Страница 82: ...UNO 1019 User Manual 74 3 Connect to the UNO 1019 again and the system will ask you to enter user name and password After authorization you will enter Windows CE networking setup page...

Страница 83: ...ame at your first usage But after you change UNO 1019 s device name please don t ever change device name back to UNO 1019 it s not permitted for WinCE OS Note When you change the device name UNO 1019...

Страница 84: ...eck Enable IPV6 and press Submit button System will ask you to restart UNO 1019 the UNO 1019 will support IPV6 after restarting Note You also could find device name in WinCE s setting Control Panel Sy...

Страница 85: ...be statically reserved and mapped System will list all of the adapters present on the UNO 1019 You can configure the adapter bindings as public private bridged or default to simply bind it to TCP IP...

Страница 86: ...ess Create 1 B Enter a password and press Create Account button 1 C System will create a user account according to your information If you would like to change the password of this user account please...

Страница 87: ...ter a group name in the Create a new field and press Create 2 B If you want to choose which users are members of group please press Modify button behind the group name Set the box next the user s name...

Страница 88: ...u want to delete a group please press Delete button behind the group name Features Allows configuration of advanced gateway features You can configure the File server FTP server Telnet server and Web...

Страница 89: ...sh to share and then enter a share name then press Submit A 2 Press Modify to set up share permissions choose the account who will use file server function then click Allowed then press Modify A 3 You...

Страница 90: ...you want to use password to protect UNO file server please key in your ADMIN password chossing PWD Enabled and click Submit every time you access file server UNO file sever will ask you a password of...

Страница 91: ...e of folder on UNO 1019 remote name user username d or net view computername DOMAIN domainname Description d Disable network disk Instance 1 Share the temp folder in the remote site nb940902 to author...

Страница 92: ...k you to enter your user name password and domainif you would like to save your user name and password as default user please check Update Default Credentials EX net use UNO1019V1 nb940902 temp user d...

Страница 93: ...asic Configuration field Server Enabled Will the FTP server accept incoming connections Require Authentication Will the FTP server prompt for user name and password Allow Anonymous Users Allow users w...

Страница 94: ...UNO 1019 User Manual 86 Logs Use Logs section to control what information about the FTP transactions is logged...

Страница 95: ...FTP server for each user To add new user please go to the User Account page You can configure a seprate home directory for each user by appending the user s name to home directory Denying read permis...

Страница 96: ...UNO 1019 User Manual 88 Virtual Roots You can add delete virtual roots to the FTP server Virtual roots allow you map a physical directory to and directory with a different name...

Страница 97: ...ows the UNO 1019 to be configured remotely Telnet Server Configuration Server Enabled Will the telnet server accept incoming connections Require Authentication Will the telnet server prompt for user n...

Страница 98: ...4 7 5 Restart Network Restart for network change to take effect To make the changes you have made take effect immediately please press Restart Networking button and then the home gateway networking s...

Отзывы: