UNO-1019 User Manual
64
2. ADV_IOCTL_WRITE_DO:
Write value out the Digital Output.
lpInBuffer : The BYTE pointer to the DO value that is requesting to write
out. BIT0 indicates DO_0 state; BIT1 indicates DO_1 state.
nInBufferSize: User provided input buffer size.
lpOutBuffer: unsed.
nOutBufferSize: unsed.
3. ADV_IOCTL_READ_DO:
Read the written Digital Output value.
lpInBuffer : unsed.
nInBufferSize: unsed.
lpOutBuffer: The BYTE pointer to the current DO value. BIT0 indicates
DO_0 state; BIT1 indicates DO_1 state.
nOutBufferSize: User provided input buffer size.
4. ADV_IOCTL_TURN_ON_LED1:
Turn LED1 on.
lpInBuffer :unused.
nInBufferSize: unused.
lpOutBuffer: unused.
nOutBufferSize: unused.
5. ADV_IOCTL_TURN_OFF_LED1:
Turn LED1 off.
lpInBuffer :unused.
nInBufferSize: unused.
lpOutBuffer: unused.
nOutBufferSize: unused.
Содержание UNO-1019
Страница 1: ...UNO 1019 PXA 200MHZ 64MBRAM 2xLAN 4xCOM Universal Network Controller User Manual...
Страница 14: ...UNO 1019 User Manual 6 Figure 1 3 UNO 1019 Front View Dimensions Figure 1 4 UNO 1019 Bottom View Dimensions...
Страница 23: ...15 Chapter 2 Figure 2 6 Digital Input Connection Dry Contact Figure 2 7 Digital Input Connection Wet Contact...
Страница 26: ...UNO 1019 User Manual 18 Then screw the whole device to the wall Figure 2 10 Attach UNO 1019 to the Wall...
Страница 30: ...UNO 1019 User Manual 22...
Страница 38: ...UNO 1019 User Manual 30...
Страница 52: ...UNO 1019 User Manual 44 3 Setup the device according to the specification of the modem and press Next...
Страница 60: ...UNO 1019 User Manual 52...
Страница 64: ...UNO 1019 User Manual 56 8 Select UNO 1019 in the main window of Visual C...
Страница 94: ...UNO 1019 User Manual 86 Logs Use Logs section to control what information about the FTP transactions is logged...