118
2.16.4 Thermal Interface
Table 47
: Thermal Management Signal Definitions
Signal
Pin# Description
I/O
Note
THRM#
B35
Thermal Alarm active low signal generated by the
external hardware to indicate an over temperature
situation. This signal can be used to initiate thermal
throttling.
Carrier Board:
Connect to THRM# output of Hardware Monitor.
N/C if not used.
I 3.3V
CMOS
THRMTRIP#
A35
Thermal Trip indicates an overheating condition of the
processor. If
'THRMTRIP#'
goes active the system
immediately transitions to the S5 State (Soft Off).
Carrier Board:
Connect to THERMTRIP# input of devices.
N/C if not used.
O 3.3V
CMOS
Note:
2.16.5 Miscellaneous Signals Routing Guidelines
NA