Chapter 2
PCI-1711/1731 User’s Manual
Advantech Co., Ltd.
www.advantech.com
– 18 –
Fig. 2-15 Digital Output tab on the Device Test dialog box
Testing Counter Function
Click the Counter Tab to bring its test panel forth. The counter
channel (Channel 0) offers the users two options: Event counting and
Pulse out. If you select Event counting, you need first to connect your
clock source to pin CNT0_CLK, and the counter will start counting
after the pin CNT0_GATE is triggered. If you select Pulse Out, the
clock source will be output to pin CNT0_OUT. You can configure the
Pulse Frequency by the scroll bar right below it.
Fig. 2-16 Digital output tab on the Device Test dialog box
Only after your card device is properly set up, configured and tested,
can the device installation procedure be counted as complete. After
the device installation procedure is completed, you can now safely
proceed to the next chpater, Signal Connections.