A SCSI bus is an electrical pathway that consists of a SCSI interface
installed in a computer and one or more SCSI devices. SCSI cables are
used to connect the devices to the SCSI interface. For the SCSI bus to
function properly, a unique SCSI ID must be assigned to the SCSI inter-
face and each SCSI device connected to it, and the SCSI bus must be
properly terminated.
6.3 SCSI IDs
Each device attached to the SCSI bus, as well as the SCSI controller
itself, must be assigned a unique SCSI ID number from 0 to 15. A SCSI
ID uniquely identifies each SCSI device on the SCSI bus and determines
priority when two or more devices are trying to use the SCSI bus at the
same time.
Refer o the device.s documentation to set the SCSI ID. Here are some
general guidelines for SCSI IDs:
• For internal SCSI devices, the SCSI ID usually is set by configuring a
jumper on the device.
• For external SCSI devices, the SCSI ID usually is set with a swetch on
the back of the device.
• SCSI ID numbers don.t have to sequential, as long as the SCSI control-
ler and each device has a different number.
• For example, you can have an internal SCSI device with ID 0, and an
external SCSI device with ID 6.
• SCSI ID 7 has the highest priority on the SCSI bus. The priority of the
remianing IDs, in descending order, is 6 to 0, then 15 to 8.
• The on-boards SCSI interface is preset to SCSI ID 7 and should not be
changed. This gives it the highest priority on the SCSI bus.
• Most internal SCSI hard disk drives come from the factory pre-set to
SCSI ID 0.
• If you have 8-bit (or Narrow) SCSI deveices, they must use SCSI IDs 0,
1, 2, 3, 4, 5, or 6. SCSI ID 0 is recommended for the first SCSI hard
disk drive.
• If you are booting your computer from a SCSI hards disk drive con-
nected to the SCSI bus, the Boot SCSI ID setting in the SCSISelect
utility must correspond to the SCSI ID of the device from which you
are booting. By default, the Boot SCSI ID is set to 0. We recommend
that you do not change this setting.
Содержание PCA-6005
Страница 1: ...PCA 6005 Full sized PCI bus socket 478 Pentium 4 Celeron processor based CPU card User s Manual...
Страница 2: ...PCA 6005 User s Manual ii...
Страница 6: ...PCA 6005 User s Manual vi...
Страница 14: ...PCA 6005 User s Manual 6...
Страница 23: ...9 Figure 1 2 SCSI daughter board layout Figure 1 3 I O connectors on bracket...
Страница 40: ...PCA 6005 User s Manual 26...
Страница 41: ...27 CHAPTER 3 Award BIOS Setup This chapter describes how to set the card s BIOS configuration data...
Страница 60: ...PCA 6005 User s Manual 46...
Страница 64: ...PCA 6005 User s Manual 50...
Страница 70: ...PCA 6005 User s Manual 56 4 In the Update Device Driver Wizard window click on Next 5 Click Next...
Страница 78: ...PCA 6005 User s Manual 64 9 In the Network Settings Change window click on Yes...
Страница 81: ...67 Chapter5 4 In the following screen to click on Update Driver 5 Click on Next...
Страница 82: ...PCA 6005 User s Manual 68 6 Following the highlighted item and click on Next 7 Click on Have Disk...
Страница 84: ...PCA 6005 User s Manual 70 11 Click Finish to complete the installation...
Страница 97: ...83 2 In the System properties choose PCI SCSI Bus Controller Then click on Properties 3 Click on Update Driver...
Страница 98: ...PCA 6005 User s Manual 84 4 Click on Next 5 Recommend to search for a better driver...
Страница 100: ...PCA 6005 User s Manual 86 8 The installation is completed Click on Finish 9 Click on Yes to restart the system...
Страница 103: ...89 5 Click the SCSI driver and then click OK 6 The installation of SCSI Driver is completed Click on OK...
Страница 104: ...PCA 6005 User s Manual 90...
Страница 113: ...99 in al dx...
Страница 114: ...PCA 6005 User s Manual 100...
Страница 130: ...PCA 6005 User s Manual 116...