31
iDAQ-934_964 User Manual
C
ha
pte
r 3
Fu
nc
tio
n D
eta
ils
The start and stop of the generation are controlled by the start trigger and stop trig
-
ger, respectively. When configuration is completed, the acquisition engine of the
iDAQ chassis is at standby state. After receiving a start trigger, generation becomes
active and each rising edge of the sample clock converts one analog output sample.
The generation active period lasts until a stop trigger is received, which ends the gen
-
eration. This is shown in Figure 3.32.
Figure 3.32 Start and stop of the digital output waveform generation
The start and stop of generation can also be delayed in number of samples after
receiving the corresponding trigger signal. As shown in Figure 3.33, the start of gen
-
eration is delayed by 3 samples after receiving a start trigger, and the stop of genera
-
tion is delayed by 2 samples after receiving a stop trigger.
Figure 3.33 Start and stop of the digital output waveform generation with delay
Refer to 3.1.1 Signal Routing for possible signal routings and configurations for these
timing signals (start trigger, stop trigger, and sample clock).
Buffered digital output waveform generation has several advantages over static digi
-
tal output update:
The start and stop time of generation (or duration of the generation) can be pre
-
cisely controlled by hardware trigger signals.
Update rate can be much higher by using hardware sample clock signal.
Time between samples is deterministic.
Содержание iDAQ-934
Страница 1: ...User Manual iDAQ Chassis iDAQ 934 iDAQ 964...
Страница 10: ...iDAQ 934_964 User Manual x...
Страница 11: ...Chapter 1 1 Start Using iDAQ Chassis...
Страница 17: ...Chapter 2 2 Installation Guide...
Страница 23: ...Chapter 3 3 Function Details Interface Introduction...
Страница 44: ...iDAQ 934_964 User Manual 34...
Страница 45: ...Appendix A A Specifications...
Страница 48: ...iDAQ 934_964 User Manual 38 A 8 Function Block iDAQ 934 iDAQ 964...
Страница 49: ...Appendix B B System Dimensions...
Страница 50: ...iDAQ 934_964 User Manual 40 B 1 Chassis iDAQ 934...
Страница 51: ...41 iDAQ 934_964 User Manual Appendix B System Dimensions iDAQ 964...
Страница 52: ...iDAQ 934_964 User Manual 42 B 2 Mounting Wall Mount for iDAQ 934...
Страница 53: ...43 iDAQ 934_964 User Manual Appendix B System Dimensions...