21
iDAQ-900 User Manual
C
ha
pte
r 3
Fu
nc
tio
n D
eta
ils
When the sample clock rises, the multiplexed analog input module automatically gen
-
erates required convert clocks using the maximum allowable convert clock rate of the
ADC for all enabled channels. The MUX routes one of the enabled channels for each
convert clock in the order of channel number. Figure 3.9 shows an example when 3
analog input channels (0, 1, and 2) are enabled. By this acquisition method, the tim
-
ing of conversion for all enabled channels can be as close as possible, which
approaches the result of a simultaneously sampled analog input module.
Figure 3.9 Acquisition of a multiplexed analog input module
Содержание iDAQ-900 Series
Страница 1: ...User Manual iDAQ 900 Series iDAQ 934 iDAQ 938 iDAQ 964 Industrial DAQ Chassis ...
Страница 10: ...iDAQ 900 User Manual x ...
Страница 11: ...Chapter 1 1 Start Using iDAQ Chassis ...
Страница 17: ...Chapter 2 2 Installation Guide ...
Страница 21: ...11 iDAQ 900 User Manual Chapter 2 Installation Guide ...
Страница 24: ...iDAQ 900 User Manual 14 ...
Страница 25: ...Chapter 3 3 Function Details ...
Страница 46: ...iDAQ 900 User Manual 36 ...
Страница 47: ...Appendix A A Specifications ...
Страница 50: ...iDAQ 900 User Manual 40 A 8 Function Block iDAQ 934 iDAQ 964 iDAQ 938 ...
Страница 51: ...Appendix B B System Dimensions ...
Страница 52: ...iDAQ 900 User Manual 42 B 1 Chassis iDAQ 934 ...
Страница 53: ...43 iDAQ 900 User Manual Appendix B System Dimensions iDAQ 964 iDAQ 938 ...
Страница 54: ...iDAQ 900 User Manual 44 B 2 Mounting Wall Mount for iDAQ 934 Wall Mount for iDAQ 938 ...
Страница 55: ...45 iDAQ 900 User Manual Appendix B System Dimensions ...