EKI-7659CPI_Manual_ed33 62
Figure 3.32: Port based mode-Add interface
•
You will see the VLAN displays.
•
Use
Delete
button to delete unwanted VLAN.
•
Use
Edit
button to modify existing VLAN group.
Note
Remember to execute the “Save Configuration” action, otherwise the new
configuration will lose when switch power off.
802.1Q VLAN
Tagged-based VLAN is an IEEE 802.1Q specification standard. Therefore, it is possible to create a VLAN
across devices from different switch venders. IEEE 802.1Q VLAN uses a technique to insert a “tag” into
the Ethernet frames. Tag contains a VLAN Identifier (VID) that indicates the VLAN numbers.
You can create Tag-based VLAN, and enable or disable GVRP protocol. There are 256 VLAN groups to
provide configure. Enable 802.1Q VLAN, the all ports on the switch belong to default VLAN, VID is 1. The
default VLAN can’t be deleting.
GVRP allows automatic VLAN configuration between the switch and nodes. If the switch is connected to
a device with GVRP enabled, you can send a GVRP request using the VID of a VLAN defined on the
switch; the switch will automatically add that device to the existing VLAN.
Содержание EKI-7659CPI
Страница 1: ...EKI 7659CPI 8 2G Combo Ports Industrial PoE Managed Redundant Gigabit Ethernet Switch User Manual ...
Страница 18: ...EKI 7659CPI_Manual_ed33 8 ...
Страница 22: ...EKI 7659CPI_Manual_ed33 12 2 2 Dimensions units mm Figure 2 1 Front View of EKI 7659CPI ...
Страница 23: ...13 Chapter2 Figure 2 2 Side View of EKI 7659CPI ...
Страница 24: ...EKI 7659CPI_Manual_ed33 14 Figure 2 3 Rear View of EKI 7659CPI ...
Страница 25: ...15 Chapter2 Figure 2 4 Top View of EKI 7659CPI ...
Страница 33: ...23 Chapter2 ...
Страница 63: ...53 Chapter3 Figure 3 22 User Authentication ...
Страница 69: ...59 Chapter3 Figure 3 29 Rate Limiting ...
Страница 93: ...83 Troubleshooting CHAPTER ...
Страница 95: ...85 Pin Assignment Wiring APPENDIX ...
Страница 98: ...EKI 7659CPI_Manual_ed33 88 ...
Страница 99: ...89 Compatible SFP Modules APPENDIX ...
Страница 101: ...91 ...