background image

www.advantech.com

Please verify specifications before quoting. This guide is intended for reference
purposes only.
All product specifications are subject to change without notice.
No part of this publication may be reproduced in any form or by any means,
electronic, photocopying, recording or otherwise, without prior written permis-
sion of the publisher.
All brand and product names are trademarks or registered trademarks of their
respective companies.
© Advantech Co., Ltd. 2016

Содержание EKI-1528CI

Страница 1: ...User Manual EKI 1528 DR Series Serial Device Server...

Страница 2: ...llation Advantech assumes no liability under the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most of our customers...

Страница 3: ...able protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and us...

Страница 4: ...ediately 1 x Serial Device Server 1 x Wall mounting Brackets 1 x DIN Rail Mounting Bracket and Screws 1 x CD ROM Warning Warnings indicate conditions which if not observed can cause personal injury Ca...

Страница 5: ...the power source to avoid damage by transient overvoltage 12 Never pour any liquid into an opening This may cause fire or electrical shock 13 Never open the equipment For safety reasons the equipment...

Страница 6: ...om damage To avoid electrical shock always disconnect the power from your PC chassis before you work on it Don t touch any components on the CPU card or other cards while the PC is on Disconnect power...

Страница 7: ...in Assignment 12 2 2 3 Power Connection 13 Figure 2 12 P Fail Alarm Application Wiring 13 2 3 Installing the Configuration Utility 14 Figure 2 13 InstallShield Wizard 1 of 4 14 Figure 2 14 InstallShie...

Страница 8: ...4 3 1 USDG TCP Client Mode 36 Figure 4 3 USDG TCP Client Mode 36 Figure 4 4 Peer for Receiving Data 37 4 3 2 USDG Data TCP Server Mode 37 Figure 4 5 USDG TCP Server Mode 37 Figure 4 6 USDG Data Mode 3...

Страница 9: ...onfiguration Basic 55 6 5 2 Operation 55 Figure 6 5 Port Configuration Operation 56 6 5 3 Advanced 57 Figure 6 6 Port Configuration Advanced 58 6 6 Monitor 59 6 6 1 Setting 59 Figure 6 7 Monitor Setti...

Страница 10: ...tion70 7 1 Overview 71 7 2 Telnet Console 71 Figure 7 1 Creating a Telnet Connection 71 Figure 7 2 Creating a Telnet Connection 71 Figure 7 3 Telnet Connection Console 72 7 3 Command List 72 Chapter A...

Страница 11: ...Chapter 1 1Overview...

Страница 12: ...ided in a later chap ter 1 2 Device Features Provides 2 x 10 100 Mbps Ethernet ports for LAN redundancy Provides COM port redirection Virtual COM TCP and UDP operation modes Supports up to 921 6 kbps...

Страница 13: ...ace Mark Flow Control XON XOFF RTS CTS DTR DSR Baud Rate 50 bps 921 6 kbps any baud rate setting Protection Built in 15 KV ESD for all signals Power Power Consumption EKI 1528I 5W EKI 1528CI 6W Power...

Страница 14: ...Chapter 2 2Getting started...

Страница 15: ...rs on page 7 for further details 2 Default button Press at least 10secs to reset device to default settings 3 ETH port RJ45 ports x 2 See LED Indicators on page 7 for further details 4 Serial port DB9...

Страница 16: ...Screw holes x6 used in the installation of a wall mounting plate 2 DIN Rail mounting plate Mounting plate used for the installation to a standard DIN rail 1 1 2 No Item Description 1 Terminal block C...

Страница 17: ...The device server has been located by utility s location function Off System is not working 4 Ethernet Amber Blinking Ethernet port is transmitting or receiv ing data Steady on Ethernet has a good lin...

Страница 18: ...1 1 DIN Rail Mounting The DIN rail mount option is the quickest installation option Additionally it optimizes the use of rail space The metal DIN rail kit is secured to the rear of the serial device...

Страница 19: ...the bottom of the server towards the DIN rail until it snaps into place Figure 2 6 Installing the DIN Rail Mounting Kit Removing the DIN Rail Mounting Kit 1 Push the server down to free the bottom of...

Страница 20: ...will need to remove the DIN rail plate 1 Rotate the device to the rear side and locate the DIN mounting plate 2 Remove the screws securing the DIN mounting plate to the rear panel of the server 3 Rem...

Страница 21: ...mount plates as a guide to mark the locations of the screw holes 8 Drill four holes over the four marked locations on the wall keeping in mind that the holes must accommodate wall sinks in addition t...

Страница 22: ...gure Figure 2 10 Wall Mount Installation 13 Once the device is installed on the wall tighten the screws to secure the device 2 2 2 Serial Connection EKI 1528 Series provides eight ports DB9 male conne...

Страница 23: ...ay opens if power input 1 or 2 fails In a wiring example where an LED is connected to the relay output the LED would be off in an Open state Warning Power down and disconnect the power cord before ser...

Страница 24: ...pro gram the path for the setup program on the CD ROM is as follows E EKI_Device_Configuration_Utility_v2 01 exe 3 If there is an existing COM port mapping utility on the host PC remove it at this ti...

Страница 25: ...ess I Agree to continue or Cancel to stop the installation Figure 2 14 InstallShield Wizard 2 of 4 The InstallShield continues and a status screen displays The default installation path is C Program F...

Страница 26: ...er Manual 16 6 Once the installation of the package is finished a Configuration Utility Setup screen displays Click Finish to conclude the process and exit the InstallShield Wizard Figure 2 16 Install...

Страница 27: ...Chapter 3 3Utility Configuration...

Страница 28: ...te Advantech serial device servers easily The utility provides access to the following functions Configure the network settings you can set the IP address Gateway address and Subnet mask View and set...

Страница 29: ...igura tion page displays Note The configuration utility makes use of TCP UDP ports 5048 and 5058 to communicate with the Advantech EKI serial device server T Please reserve TCP UDP port 5048 and 5058...

Страница 30: ...serial device server to the network Icon Item Description Item Description Main Window Settings Maximum Main Window On Load Check the box to enable the limiting of main windows on load to the maximum...

Страница 31: ...ond Enter a value to specify the time to auto detection time 1 means disable auto detection Auto detect devices every X second Enter a value to specify the time to auto detect devices Check device ali...

Страница 32: ...n the device name to show the features of the specific device Click on the before the model name and the utility will expand the tree structure to show the individual device name Click on the before t...

Страница 33: ...rmation In the serial port information frame it dis plays the operation mode status and connected host IP Figure 3 6 Selecting a Group Click on the before the device name and the utility will expand t...

Страница 34: ...AutoIP mode to automatically assign IP addresses through a DHCP server BOOTP AutoIP mode to automatically assign an IP address through the con figuration server DHCP BOOTP AutoIP mode to automatically...

Страница 35: ...and DNS BOOTP Auto IP BOOTP Server assigned IP address DHCP BOOTP Auto IP DHCP Server assigned IP address Subnet Mask Default Gate way and DNS or BOOTP Server assigned IP address If the DHCP Server d...

Страница 36: ...ate the Serial Device Server When several serial device servers are connected to the network identification of a specific serial device is possible through the Locate function To locate the serial dev...

Страница 37: ...Lock Unlock the Serial Device Server Password Protection The configuration utility provides the Lock Device function to make it more secure You need to set up a password the first time by clicking Loc...

Страница 38: ...e Figure 3 12 Lock the Serial Device Server 3 Enter a password and re confirm the profile password Figure 3 13 Enter a Password 4 After re confirming the password the serial device server will reboot...

Страница 39: ...ank The serial device server will restart and store the new password in the memory Figure 3 14 Unlock the Serial Device Server 3 4 3 Change Password To unlock the serial device server 1 Right click a...

Страница 40: ...vice allows you to reset the serial device server The function discon nects both the ethernet and serial connections The function also allows the serial device server to save new configuration setting...

Страница 41: ...irmware Advantech continually upgrades its firmware to keep up with the ever expending world of computing You can use the update firmware function in the utility to carry out the upgrade procedure Ple...

Страница 42: ...e completely click on the OK button The serial device server will restart automat ically Note Be sure that the host PC Ethernet network domain is as same as the EKI 1528 Series serial device server or...

Страница 43: ...Chapter 4 4Selecting an Operating Mode...

Страница 44: ...erver You can configure the serial device server and enable the Virtual COM port using one integrated utility Advantech EKI Device Configuration Utility allows you to configure Microsoft applications...

Страница 45: ...ta will also be transmitted to the connected hosts simultaneously 4 2 2 Round Robin mode By enabling the Response Timeout parameter the EKI 1528 Series operates in Round Robin mode Each serial port su...

Страница 46: ...EKI 152X series to one host or several hosts You can configure the IP address and TCP port number of the network hosts connected to the EKI serial device server using the Advantech Serial Device Serv...

Страница 47: ...device server This operation mode supports a maximum of five simultaneous con nections for each serial port on an EKI serial device server from a single or multiple hosts However a multi host connect...

Страница 48: ...e is 1024 65533 If an unknown caller wants to connect to the system and request services they must define the TCP UDP port to carry a long term conversation Each node on a TCP IP network has an IP add...

Страница 49: ...Mode is designed for use with legacy operating systems such as MSDOS that do not support TCP IP Ethernet By connecting one of the EKI s serial ports to the MS DOS computer s serial port it is possibl...

Страница 50: ...ies devices to a local COM port on a host computer RFC2217 defines general COM port control options based on the Telnet protocol Third party drivers supporting RFC2217 are widely available on the Inte...

Страница 51: ...Chapter 5 5Setting Up COM Port Redirector...

Страница 52: ...al COM port management utility are integrated into one utility with same GUI The Advantech EKI Device Configuration Utility can create all Virtual COM ports using the Auto Mapping function or by using...

Страница 53: ...Selected Ports Once the mapping function is initialized a successful mapping process results in the virtual mapping of the designated physical serial port and VCOM PC port See the following figure Fi...

Страница 54: ...his is the physical serial port on the EKI device 6 In the Host COM Port drop down menu select the target COM port to map This is the virtual port on the target PC Figure 5 6 Selecting Manual Mapping...

Страница 55: ...y and click Advantech EKI Device Configuration Utilityto open the utility 2 Under Serial Device Servers locate your server and click the icon to expand the listing 3 From the tool bar select Configura...

Страница 56: ...rts 3 Select a VCOM port to view its settings Figure 5 9 Serial Port Listing on EKI Device For the next step you will need to open the device manager on your system Using the Device Manager you can bo...

Страница 57: ...ration The newly mapped VCOM port is listed under the same mapped settings used in the previous steps The settings correspond to the VCOM port configuration on the EKI device see the following figure...

Страница 58: ...Device Configuration Utility A Remove Port confirmation window displays 5 Click OK to continue with the removal process or Cancel to return to the previ ous menu Once the procedure is completed a prom...

Страница 59: ...option is selected an external test will be run to check that the con nection signals for each port are working properly For the test you will need to con nect each port to a loopback tester provided...

Страница 60: ...EKI 1528 DR Series User Manual 50 1 Click Simple Serial Test in the Tools menu Figure 5 14 Running a Diagnostic Test...

Страница 61: ...Chapter 6 6Web Configuration...

Страница 62: ...or this device Once the IP is entered you will be presented with the following windows 6 2 Accessing the Web Page 6 2 1 Accessing the Web Page via Configuration Utility To access the web page via conf...

Страница 63: ...re Item Description Firmware version Displays the current firmware version of the device Revision number Displays the revision number of the device Device Name Enter the device name up to 31 alphanume...

Страница 64: ...Setting mode Static IP DHCP or BOOTP MAC Address Enter the MAC address to which packets are statically forwarded IP Address Enter a value to specify the IP address of the interface The default is 10 0...

Страница 65: ...lated attri butes for port configuration Note All new configurations will take effect after rebooting To reboot the device click Tools Reboot Item Description Type Click the drop down menu to select a...

Страница 66: ...timeout period Response Timeout ms Enter a value to define the response timeout period Frame Break ms Enter a value to specify the frame break time Pack conditions Pack sent immediately when reach 10...

Страница 67: ...nt pack immediately by interval By end character Click the option to sent pack immediately by end character By character time out Click the option to sent pack immediately by character timeout Peer fo...

Страница 68: ...Timeout Detection Click the option to disable the serial port character timeout detection Disable Multiple Connection Click the option to disable the multi access function Then only one TCP connection...

Страница 69: ...page click Monitor Setting Figure 6 7 Monitor Setting TTL Transmitter Trigger Level Click the option to designate to suspend or resume transmission FCL Flow Control Lower Trigger Levels Click to set r...

Страница 70: ...CTS Display the current RTS CTS status of the selected port XON XOFF Display the current XON OFF status of the selected port DTR DSR Display the current DTR DSR status of the selected port Save Click...

Страница 71: ...t On the Alert Settings page you may configure how administrators are notified by ce tain system network configuration power and cellular connection events Rely on the events administrators can collec...

Страница 72: ...mail warnings will be sent Email addresses 1 4 This is the e mail address or addresses to which the automatic e mail warnings will be sent SNMP Trap Server Trap Server Use this field to indicate the...

Страница 73: ...record or send event mesages System event notification is available for cold start warm start authentication failure IP address Password change serial DCD DSR port change and Ethernet link down inform...

Страница 74: ...click Alarm Event Figure 6 11 Alarm Event 1 of 2 The following table describes the items in the previous figure Item Description System Event Cold Start Click the option to select a warning type when...

Страница 75: ...assword is entered IP address changed Click the option to select a warning type when the IP address is changed Password changed Click the option to select a warning type when the password is changed E...

Страница 76: ...gd Syslogd Message Figure 6 13 Syslogd Syslogd Message 6 9 Tools The EKI serial device server provides tools for access to ping and reset functions 6 9 1 Ping The ping page can help users diagnose eth...

Страница 77: ...e last time you issued a save will be lost Item Description IP Enter the IP address or host name of the station to ping The initial value is blank The IP Address or host name you enter is not retained...

Страница 78: ...ange Password The Change Password function allows you to easily update your current password from a single menu To access this page click Management Change Password Figure 6 16 Management Change Passw...

Страница 79: ...than 0 restricted to listed Access IP listing To access this page click Management Secure access IP Figure 6 17 Management Secure access IP The following table describes the items in the previous fig...

Страница 80: ...Chapter 7 7Telnet Serial Console Configuration...

Страница 81: ...d other related terminal software 7 2 Telnet Console Create a new connection You can create a new Telnet connection and assign a connection name for the con sole configuration Figure 7 1 Creating a Te...

Страница 82: ...ports information portadv Show or configure the serial ports advanced settings mvcom Show or configure the serial ports in Virtual COM mode mctr Show or configure the serial ports in Control mode USDG...

Страница 83: ...en Parity parity o Odd Parity parity m Mark Parity parity s Space Parity Set serial baud rate parity and numbers of data bits numbers of stop bits Usage port nn all mode vcom ctrl data Set serial port...

Страница 84: ...bytes or time ms and character HEX value 0 None Setting mctrl Usage mctrl Show port mode and mode informations Usage mctrl nn all Set port nn all as control mode Usage mctrl nn all idleto tcpp atp gua...

Страница 85: ...ew password Usage password old new 1 31 characters Confirm the old password and set new password alarm Usage alarm Show current alarm informations Usage alarm mail server null address from null addres...

Страница 86: ...t enable disable Enable Disable telnet function Usage service snmp enable disable Enable Disable SNMP function mrfc2217 Usage mrfc2217 Show all port mode and mode informations Usage mrfc2217 nn all Se...

Страница 87: ...Appendix A ATCP and UDP Port Numbers...

Страница 88: ...ation Utility 5202 TCP VCOM RVCOM 9999 TCP Firmware Download 22 TCP SSH 23 TCP Telnet 25 TCP SMTP Mail Client 53 TCP UDP DNS 67 UDP BOOTP Server DHCP 68 UDP BOOTP Client DHCP 80 TCP Web Interface HTTP...

Страница 89: ...tions are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion of...