EKI-136x-MB-BE Series User Manual
4.8.2
Event
The Alarm Event page allows the selection of triggers for system, DCD and DSR
events for the alarm function.
To access this page, click
Alarm
>
Event
.
Figure 4.20 Alarm > Event
The following table describes the items in the previous figure.
Item
Description
System Event
Cold Start
Click the option to select a warning type when the device’s power
is cut off and reconnected.
Warm Start
Click the option to select a warning type when the device is reboot.
Authentication failure
Click the option to select a warning type when an incorrect
password is entered.
IP address changed
Click the option to select a warning type when the IP address is
changed.
Password changed
Click the option to select a warning type when the password is
changed.
LAN Interface 1 link
down
Click the option to select a warning type when the LAN Interface 1
port is disconnected.
DCD changed
Port
Click the option to select a warning type of the selected port when
a change in the DCD (Data Carrier Detect) signal indicates that the
modem connection status has changed.
DSR changed
Port
Click the option to select a warning type of the selected port when
a change in the DSR (Data Set Ready) signal indicates that the
data communication equipment is powered off.
Apply
Click
Apply
to save the values and update the screen.
Содержание EKI-136-MB-BE Series
Страница 1: ...User Manual EKI 136x MB BE Series 1 2 port RS 232 422 485 to 802 11a b g n WLAN Modbus Gateway...
Страница 11: ...Chapter 1 1Introduction...
Страница 16: ...Chapter 2 2Getting Started...
Страница 32: ...Chapter 3 3Utility Configuration...
Страница 46: ...Chapter 4 4Web Interface...
Страница 71: ...Chapter 5 5Telnet Serial Console Configuration...