background image

EKI-1242 Series User Manual

52

3.7

Tools

3.7.1

Modbus Traffic Catcher

The Modbus Traffic Catcher page shows only data sent and received by Modbus.
To access this page, click 

Tools

 > 

Modbus Traffic Catcher

.

Figure 3.31 Tools > Modbus Traffic Catcher

The following table describes the items in the previous figure.

Item

Description

Start

Click 

Start

 to start capturing the data.

Stop

Click 

Stop

 to stop capturing the data.

Export

Click 

Export

 to export and download the captured data.

Auto Scroll

Check the option to cycle through all of the data screens automatically 

while start capturing data.

Содержание EKI-1242 Series

Страница 1: ...User Manual EKI 1242 Series Modbus RTU TCP to BACnet IP MSTP EtherCAT EtherNet IP PROFINET Fieldbus Gateway...

Страница 2: ...ation Advantech assumes no liability under the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most of our customers n...

Страница 3: ...nd can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a re...

Страница 4: ...er immediately 1 x Fieldbus gateway 1 x DIN Rail mounting bracket and screws 1 x Wall mounting bracket Warning Warnings indicate conditions which if not observed can cause personal injury Caution Caut...

Страница 5: ...open the equipment For safety reasons the equipment should be opened only by qualified service personnel If one of the following situations arises get the equipment checked by service personnel The po...

Страница 6: ...NTAINS IMPORTANT SAFETY INSTRUCTIONS CONSERVER CES INSTRUCTIONS CETTE NOTICE CONTIENT DES INSTRUCTIONS IMPORTANTES CONCERNANT LA S CURIT WARNING SHOCK HAZARD ONLY FOR MOUNTING IN A RACK OR ENCLOSURE F...

Страница 7: ...period The following guidelines are also recommended Wear a grounded wrist or ankle strap and use gloves to prevent direct contact with the device before servicing the device Avoid nylon gloves or wor...

Страница 8: ...on 20 2 6 MicroSD Card Installation 21 2 6 1 Installing a MicroSD Card 21 2 6 2 Utilizing a MicroSD Card 22 2 7 Power Supply Installation 23 2 7 1 Overview 23 2 7 2 Considerations 24 2 7 3 Grounding t...

Страница 9: ...EKI 1242 Series User Manual ix 3 6 2 Backup Manager 49 3 6 3 Upgrade Manager 50 3 6 4 Reset System 50 3 6 5 Reboot Device 50 3 6 6 Apply Configuration 51 3 7 Tools 52 3 7 1 Modbus Traffic Catcher 52...

Страница 10: ...ure 2 19 Terminal Receptor Relay Contact EKI 1242BNMS EKI 1242IBNMS 26 Figure 2 20 Removing a Terminal Block 26 Figure 2 21 Installing DC Wires in a Terminal Block 27 Figure 2 22 Securing a Terminal B...

Страница 11: ...re 3 27 System Management Upgrade Manager 50 Figure 3 28 System Management Reset System 50 Figure 3 29 System Management Reboot Device 51 Figure 3 30 System Management Apply Configuration 51 Figure 3...

Страница 12: ...Chapter 1 1Product Overview...

Страница 13: ...m LED P1 P2 Status Protocol LED EKI 1242BNMS EKI 1242IBNMS BACnet IP BN Modbus MS EKI 1242ECMS EKI 1242IECMS EtherCAT EC Modbus MS EKI 1242EIMS EKI 1242IEIMS EtherNET IP EI Modbus MS EKI 1242PNMS EKI...

Страница 14: ...s 2 Default Press less than 5 seconds to restart the device press over 5 seconds to reset to factory default 3 ETH port RJ45 port for Modbus TCP and device configuration 4 ETH port RJ45 port for BACne...

Страница 15: ...s 2 Default Press less than 5 seconds to restart the device press over 5 seconds to reset to factory default 3 ETH port RJ45 port for Modbus TCP and device configuration 4 ETH port RJ45 port for Ether...

Страница 16: ...ls 2 Default Press less than 5 seconds to restart the device press over 5 seconds to reset to factory default 3 ETH port RJ45 port for Modbus TCP and device configuration 4 ETH port RJ45 port for Ethe...

Страница 17: ...tails 2 Default Press less than 5 seconds to restart the device press over 5 seconds to reset to factory default 3 ETH port RJ45 port for Modbus TCP and device configuration 4 ETH port RJ45 port for P...

Страница 18: ...plate Mounting plate used for the installation to a standard DIN rail 1 No Item Description 1 Wall mounting screws Screw x4 used in the installation of a wall mounting plate 2 Terminal block Connect...

Страница 19: ...R1 N2 L2 N L1 1A 24V 2 1 3 No Item Description 1 Wall mounting holes Screw holes x4 used in the installation of a wall mounting plate 2 Component cover Open to access microSD card port only supports F...

Страница 20: ...power error condition exists P2 Green Power 2 is ON Off Power 2 is off or power error condition exists Status Orange Blinking System is ready Solid Restore config from SD card successfully to factory...

Страница 21: ...is 10M Catalog LED Name LED Color Description Catalog LED Name LED Color Description System LED P1 Green Power 1 is ON Off Power 1 is off or power error condition exists P2 Green Power 2 is ON Off Pow...

Страница 22: ...inking System is ready Solid Restore config from SD card successfully to factory default state during booting Backup config to SD card successfully during booting Automatically Backup function is disa...

Страница 23: ...35 1 378 33 1 299 11 60 0 457 20 53 0 808 15 0 591 104 4 094 140 5 512 140 5 512 9 80 0 386 40 1 575 42 1 654 42 1 654 30 50 1 201 95 3 740 95 3 740 47 05 1 852 47 95 1 888 35 1 378 33 1 299 11 60 0 4...

Страница 24: ...8 33 1 299 11 60 0 457 20 53 0 808 15 0 591 104 4 094 140 5 512 140 5 512 9 80 0 386 40 1 575 42 1 654 42 1 654 30 50 1 201 95 3 740 95 3 740 47 05 1 852 47 95 1 888 35 1 378 33 1 299 11 60 0 457 20 5...

Страница 25: ...Chapter 2 2Fieldbus Gateway Installation...

Страница 26: ...can overheat To prevent performance degradation and damage to the fieldbus gateway make sure there is clearance at the top and bottom and around the exhaust vents 2 1 1 Connecting Hardware In this in...

Страница 27: ...p of the DIN rail clip hooks over the top of the DIN rail as shown in the following illustration Make sure the DIN rail is inserted behind the spring mechanism 2 Once the DIN rail is seated correctly...

Страница 28: ...is correctly installed Otherwise re attempt the installation process from the beginning 2 3 1 2 Removing the DIN Rail Mounting Kit 1 Ensure that power is removed from the fieldbus gateway and disconne...

Страница 29: ...to the rear panel of the fieldbus gateway 3 Remove the DIN mounting plate Store the DIN mounting plate and provided screws for later use 4 Remove the screws securing on the top and bottom of the devi...

Страница 30: ...st accommodate wall sinks in addition to the screws To mount the wall plate use screws of the size shown in the following illustration Figure 2 5 Wall Mounting Screw Dimensions 10 Align the wall mount...

Страница 31: ...g may be used to provide further protection Figure 2 7 Ethernet Plug Connector Pin Position Maximum cable length 100 meters 328 ft for 10 100BaseT 2 5 Serial Connection EKI 1242 Series provides eight...

Страница 32: ...he file system on the microSD card is set to FAT32 or exFAT If necessary format the microSD card and then continue with the procedure 2 Remove the screw securing the component cover Figure 2 9 Removin...

Страница 33: ...a microSD card with a valid configuration file Power on the device The device uses the valid configuration settings in the microSD card Backup management Device setting is not factory default Enable A...

Страница 34: ...er loss EKI 1242 Series support 12 to 48 VDC Dual power inputs are supported and allow you to connect a backup power source Figure 2 14 Power Wiring for EKI 1242 Series Warning Power down and disconne...

Страница 35: ...r more effective management and servicing 2 7 3 Grounding the Device Note Routing communications and power wiring through the same conduit may cause signal interference To avoid interference and signa...

Страница 36: ...wired and then installed onto the terminal receptor located on the EKI 1242 Series Figure 2 16 Terminal Receptor Relay Contact Figure 2 17 Terminal Receptor Relay Contact EKI 1242BNMS EKI 1242IBNMS T...

Страница 37: ...gateway or the power converter before proceeding 1 Loosen the screws securing terminal block to the terminal block receptor 2 Remove the terminal block from the fieldbus gateway Figure 2 20 Removing a...

Страница 38: ...7 Insert the terminal block and press it in until it is flush with the terminal block receptor 8 Tighten the screws on the terminal block to secure it to the terminal block receptor If there is no ga...

Страница 39: ...Chapter 3 3Managing Fieldbus Gateway...

Страница 40: ...splays 3 Enter the default user name and password admin admin to log into the management interface You can change the default password after you have successfully logged in 4 Click Login to enter the...

Страница 41: ...Device Information Figure 3 3 Overview Device Information System The following table describes the items in the previous figure Figure 3 4 Overview Device Information Modbus TCP Item Description Model...

Страница 42: ...previous figure Item Description MAC Address Displays the MAC address of the device Mode Displays the IP address setting mode of the device IP Address Displays the assigned IP address of the device S...

Страница 43: ...Counter Connect Error Counter and Write Error Counter The following tables are only available for EKI 1242EIMS EKI 1242IEIMS The ensuing table for EtherNet IP Instance table settings is for reference...

Страница 44: ...onnect Status Read Counter Write Counter Connect Error Counter Connect Error Counter and Write Error Counter 3 2 3 Data View I O Data View function allows for the display of exchanged data for all I O...

Страница 45: ...splays the menu as found in the EKI 1242ECMS EKI 1242IECMS Figure 3 9 Overview Data View The following table describes the items in the previous figure Item Description Auto Refresh Check the option t...

Страница 46: ...plays the menu as found in the EKI 1242EIMS EKI 1242IEIMS Figure 3 10 Overview Data View The following table describes the items in the previous figure Item Description Auto Refresh Check the option t...

Страница 47: ...EKI 1242 Series User Manual 36 The following figure displays the menu as found in the EKI 1242PNMS EKI 1242IPNMS Figure 3 11 Overview Data View...

Страница 48: ...P Address Enter a value to specify the IP address of the interface The default is 192 168 1 1 Subnet Mask Enter a value to specify the IP subnet mask for the interface The default is 255 255 255 0 Gat...

Страница 49: ...1 Subnet Mask Enter a value to specify the IP subnet mask for the interface The default is 255 255 255 0 Gateway Enter a value to specify the default gateway for the interface The default is 192 168 1...

Страница 50: ...255 0 Gateway Enter a value to specify the default gateway for the interface The default is 192 168 1 254 Modbus TCP and EtherNet IP interface use the same IP address setting Check the option to use s...

Страница 51: ...Mode Click the drop down menu to select the IP address setting mode Static address or DHCP client IP Address Enter a value to specify the IP address of the interface The default is 192 168 1 1 Subnet...

Страница 52: ...ion Type Click the drop down menu to select a serial interface RS232 RS422 or RS485 Baud Rate Enter a value to specify the baud rate The value should conform to the current transmission speeds of conn...

Страница 53: ...figure Item Description Baud Rate Click the drop down menu to specify the baud rate The value should conform to the current transmission speeds of connected devices when setting the baud rate Submit C...

Страница 54: ...his page click Protocol Setting EtherNet IP Setting Figure 3 20 Protocol Setting EtherNet IP Setting Max Info Frames Available under MSTP mode Enter the variable defining the Max Info Frames setting T...

Страница 55: ...Enabled Exception Code in I O Map Select Enabled to dedicate the last 64 bytes of data from the EtherNet IP network stream default Enabled Submit Click Submit to save the values and update the screen...

Страница 56: ...Data Swap Response Timeout I O Disconnect Safe Value Add click to add a new transaction Edit click to modify existing transactions Delete click to delete existing transactions Copy click to copy an e...

Страница 57: ...or RTU TCP Modbus TCP communication over TCP IP networking RTU Modbus RTU communication via the serial port Slave IP Address Enter the IP address of the Modbus TCP server on Modbus TCP mode Port Ente...

Страница 58: ...wap The Data Swap field determines the order in which the particular bytes of the received transmitted data are delivered None Do not swap Word 0x01 0x02 becomes 0x02 0x01 Double Word 0x01 0x02 0x03 0...

Страница 59: ...t Data Size Byte and Input Data Byte range The ensuing table for Output Mapping Overview table settings is for reference only Output Data Byte buffer view Output Data Name Output Data Function Code Ou...

Страница 60: ...u to backup configuration settings from the device or restores a configuration file to the device To access this page click System Management Backup Manager Figure 3 25 System Management Backup Manage...

Страница 61: ...t Reset System Click Reset to have all configuration parameters reset to their factory default values All changes that have been made will be lost even if you have issued a save Reset settings take ef...

Страница 62: ...3 29 System Management Reboot Device 3 6 6 Apply Configuration To access this page click System Management Apply Configuration Click Apply and Reboot to have configuration changes you have made to be...

Страница 63: ...c Catcher Figure 3 31 Tools Modbus Traffic Catcher The following table describes the items in the previous figure Item Description Start Click Start to start capturing the data Stop Click Stop to stop...

Страница 64: ...tions are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permission of...

Отзывы: