EKI-1242 Series User Manual
3.5.2
EtherCAT Setting
The EtherCAT Setting page is only available for EKI-1242ECMS/EKI-1242IECMS.
To access this page, click
Protocol Setting
>
EtherCAT Setting
.
Figure 3.19 Protocol Setting > EtherCAT Setting
The following table describes the items in the previous figure.
3.5.3
EtherNet/IP Setting
On the EtherNet/IP network, the gateway transmits mapped data to scanner through
I/O data. The first two I/O mapped bytes in either direction can be dedicated for
status/control information, and another 64 bytes of data coming from the Modbus/
TCP network can feature the Modbus exception codes.
The EtherNet/IP Setting page is only available for EKI-1242EIMS/EKI-1242IEIMS.
To access this page, click
Protocol Setting
>
EtherNet/IP Setting
.
Figure 3.20 Protocol Setting > EtherNet/IP Setting
Max Info Frames
Available under MSTP mode. Enter the variable defining the Max Info
Frames setting. The Max Info Frames setting should be high enough
to allow for the transmission of at least as many MS/TP frame packets
as there are available MS/TP frame buffers.
MAC Address
Available under MSTP mode. Enter the MAC address of the identified
devices connected to the serial bus.
Submit
Click
Submit
to save the values and update the screen.
Item
Description
Item
Description
Device Status/
Control Word in I/O
Map
Select
Enabled
to dedicate the first two I/O mapped bytes for status/
control information (default:
Disabled
).
Exception Code in I/
O Map
Select
Enabled
to dedicate the last 64 bytes of data from the
EtherCAT network stream (default:
Disabled
).
Submit
Click
Submit
to save the values and update the screen.