ARMA-C250-CRM
18
TABLE 6
: CONNECTORS
Conn.
Function
Description
Mating Connector
(J1)
RF Input
N - Type (F)
N - Type (M)
(J2)
Serial Interface
DE - 9S (F)
DE - 9P (M)
(J3)
Discrete Interface
DB - 25S (F)
DB - 25P (M)
(J4)
RF Output Monitor
N - Type (F)
N - Type (M)
(J5)
AC Line
IEC - 320 (M)
standard sheets C-20
contact style 6.3 mm QD tabs
IEC - 320 (F)
standard sheets C-19
(connector is provided)
(J6)
Redundant Interface
DA - 15S (F)
DA - 15P (M)
(J7)
RF Output
CPR - 137 (Grooved)
CPR -1 37 (Flat)
(J8)
RF Input Monitor
N - Type (F)
N - Type (M)
TABLE 7
: RS-485 INTERFACE
Baud rate
9600 (default factory setting)
Data Bits
7
Stop Bit
1
Parity
EVEN
TABLE 8
: SERIAL RS-485 INTERFACE (J2) – PIN ASSIGNMENTS
Name
Type
Pin #
Active condition
TX485_H
Serial port (output)
6
Serial transmit port, RS-485 TX + levels.
TX485_L
Serial port (output return)
4
Serial transmit port, RS-485 TX - levels.
RX485_H
Serial port (input)
9
Serial receive port, RS-485 RX + levels.
RX485_L
Serial port (input return)
3
Serial receive port, RS-485 RX - levels.
RS485_C
Serial port (common)
5
System common.
RS485_G
Serial port (ground)
1
Shield ground / safety ground
Содержание ARMA-C250-CRM
Страница 13: ...ARMA C250 CRM 12 Figure 1 Product Outline redundant system front and rear views...
Страница 14: ...ARMA C250 CRM 13 Figure 2 Waveguide Connections top view side view...
Страница 56: ...ARMA C250 CRM 55 Figure 12 Product Outline single unit...
Страница 57: ...ARMA C250 CRM 56 Figure 13 3 D View of the Redundant System in rack cabinet...
Страница 58: ...ARMA C250 CRM 57 Figure 14 Enlarged 3 D View of the Redundant System in rack cabinet...