12
ADAM-4550 User's Manual
3.
Select the Upload menu. A dialog box will
open. Enter the file name where the firm-
ware to be uploaded is located. Click the
OK button to begin uploading. The yellow
LED light on ADAM-4550 now changes to a
steady glow. When uploading is complet-
ed, the yellow LED will turn off and blinks
again for reconfiguration. The ADAM-4550
unit is now ready to be configured. Follow
procedures in section A to re-configure the
unit.
2.7 Using the Diagnostics Functions
Start the ADAM Configuration and Diagnostic
Program. Select the Diagnostics menu. A
dialog box will open. Enter the selected ADAM-
4550 unit ID address and the communication
port baud rate. Click the OK button. The RF link
quality indicator will be displayed:
Total Received Packets indicates the total
number of packets received by the selected
ADAM-4550 unit.
CRC Error indicates the number of received
packets with the CRC checking error.
Check Sum indicates the number of received
packets with the Check Sum error.
Good Packets indicates the number of received
good packets without CRC error and Check Sum
error.
Transmit acknowledged indicates the total
number of acknowledged packets received by
the selected ADAM-4550 unit from the remote
ADAM-4550 unit.
Transmit retransmitted indicates the total
number of retransmitted packets sent out from
the selected ADAM-4550 unit due to poor link
quality (i.e. no acknowledgment received).