background image

 

 

Key in the Tag Name of output channel 

 

Key in the description of output channel 

Содержание ADAM-6050W

Страница 1: ...nput and 6 digital output channels with 5000VRMS Isolating protection All of the Digital Input channels support input latch function for important signal handling Mean while these DI channels allows to be used as 1 KHz counter Opposite to the intelligent DI functions the Digital Output channels also support pulse output function ADAM 6050W Figure 1 ADAM 6050W 18 channel Digital I O Module ...

Страница 2: ...al Input Dry Contact Logic level 0 Close to GND Logic level 1 Open Wet Contact Logic level 0 3 Vmax Logic level 1 10 to 30 VDC Digital Output Open Collector to 30 V 200 mA max load Communication Wireless LAN IEEE802 11b Optical Isolation 5000VRMS Power Consumption 2 W Typical ...

Страница 3: ...Application Wiring Figure 2 ADAM 6050W Digital Input Wet Contact Wiring Figure 3 ADAM 6050W Digital Input Dry Contact Wiring ...

Страница 4: ...Figure 4 ADAM 6050W Digital Output Wiring ...

Страница 5: ...System Architecture ...

Страница 6: ...Address Default Gateway of ADAM 6050W module to be compatible with user s existing network and set the host idle time out value the ADAM 6000 module can only accept 8 connection from host station Any host station doesn t request the communication with this ADAM 6000 module over the time out setting the connection of this host station will be released for the other stations press Apply to download ...

Страница 7: ...e with user s existing network then re start the utility software The software will automatically search the ADAM 6050W module again Step 4 Go to the Wireless page to set the wireless LAN configuration Please set the wireless LAN mode to be Infrastructure or Adhoc based on exact system architecture ...

Страница 8: ...s AP Or key in the specific SSID to assign the dedicated AP strongly recommending to set up the dedicated SSID it can guarantee the communication of ADAM 6000W modules to be stable For assigning the dedicated wireless LAN AP user can use the site survey function to check the existing AP in connection environment Please go to the Site Survey page Press Scan bottom to search the existing AP ...

Страница 9: ...Selecting the AP in the searching result table Press Apply bottom to accept the AP to finish the set up action ...

Страница 10: ...Please select the region for your area Setting the used channel the channel number must be included in the channel segment of your region Please select the basic rate for the communication bandwidth ...

Страница 11: ... 5 Configure the WEP security setting Please go to the WEP page in Wireless of utility software If user want to use the WEP security function please enable the WEP function in User WEP then select the Key format and key in the WEP key for this requirement ...

Страница 12: ...larly broadcast data to specific host PCs Click the tab of Data Stream then configure the broadcasting interval and the specific IP addresses which need to receive data from the specific ADAM 6000 I O module This UDP Data Stream function broadcasts up to 8 host PCs simultaneously and the interval is user defined from 50ms to 7 Days ...

Страница 13: ...elect the item Monitor Data Stream in the function bar or click icon to call up operation display as below Figure Select the IP address of the ADAM 6000 you want to read data then click Start button The Utility software will begin to receive the stream data on this operation display ...

Страница 14: ...gurable web page feature Users don t have to learn the Java language to write the Java program to make the customized web page Users can use the utility software to easily configure the web page that you want Please follow the below instruction to configure the web page inside ADAM 6000W modules Press the web page configuration bottom ...

Страница 15: ...Key in the Tag Name of input channel Key in the description of input channel Press the label bottom to configure the label description of input channel ...

Страница 16: ...Key in the Tag Name of output channel Key in the description of output channel ...

Страница 17: ...Press the label bottom to configure the label description of output channel Click the title position to configure the page title description ...

Страница 18: ...e web page configuration Press Update bottom to download the web page configuration into ADAM 6000W module And system will save the configuration data as a file in C Programs ADAM 5000TCP 6000 Utility Program Firmware ADAM 6050W ADAM6050W Html ...

Страница 19: ...User can also retrieve the previous web page configuration file to download to ADAM 6000W Module ...

Страница 20: ...Select the stored web page configuration file then press Open Follow the above action to download the selected file into ADAM 6000W module ...

Страница 21: ...Firmware Update Step 1 Press the browse bottom of firmware Step 2 Select the firmware file to be downloaded Step 3 Press Update bottom to finish the firmware update action ...

Страница 22: ...curity protect it means sometimes noise or other reasons will cause the communication fail and the host PC won t control the modules anymore but the modules will keep the latest output status and this status may cause dangerous so while this situation happen the communication WDT will detect it till timeout then reset the module and set the output to safety value to prevent the dangerous user can ...

Страница 23: ...O delay For typical DO setting For Pulse Output setting User can set the Lo Hi sign width based on exact requirement The pulse output also support the limited count and continuous pulse output please select this function in the block of How Many Pulse Count to Output Please click the Update to download the configuration into ADAM 6050W module then clicking the To start pulse output to initiate the...

Страница 24: ...For Lo to Hi delay and Hi to Lo delay function ...

Страница 25: ...click on DI XX to access the digital input configuration page The digital input channel of ADAM 6068 supports typical DI counter frequency Lo to Hi Latch and Hi to Lo Latch For typical DI setting For Counter setting ...

Страница 26: ...For Frequency setting ...

Страница 27: ...For Lo to Hi Latch and Hi to Lo Latch setting ...

Страница 28: ...ry wireless setting and default IP subnet mask Therefore user can re configure the wireless setting when module s communication is dead Note the temporary wireless setting will be cleared after reboot to Normal mode Diagnostic mode default settings Diagnostic Ad hoc mode setting Temporary SSID WLAN Temporary Channel 10 Temporary Wep No IP 10 0 0 1 Subnet mask 255 0 0 0 Gateway 0 0 0 0 Diagnostic I...

Страница 29: ... R 00018 1 DO R W 40027 40028 1 Pulse Output Low Level R 00019 2 DO R W 40029 40030 0 Pulse Output Low Level R 00020 3 DO R W 40031 40032 1 Pulse Output Low Level R 00021 4 DO R W 40033 40034 0 Pulse Output Low Level R 00022 5 DO R W 40035 40036 1 Pulse Output Low Level R 00033 0 Counter Start 1 Stop 0 R W 40037 40038 0 Pulse Output High Level R 00034 0 Clear Counter 1 R W 40039 40040 1 Pulse Outp...

Страница 30: ...00051 4 Clear Overflow R W 40063 40064 1 Set Incremental Pulse R 00052 4 Latch Status Clear Status R W 40065 40066 2 Set Incremental Pulse R 00053 5 Counter Start 1 Stop 0 R W 40067 40068 3 Set Incremental Pulse R 00054 5 Clear Counter 1 R W 40069 40070 4 Set Incremental Pulse R 00055 5 Clear Overflow R W 40071 40072 5 Set Incremental Pulse R 00056 5 Latch Status Clear Status R W 00057 6 Counter S...

Страница 31: ...erflow R W 00076 10 Latch Status Clear Status R W 00077 11 Counter Start 1 Stop 0 R W 00078 11 Clear Counter 1 R W 00079 11 Clear Overflow R W 00080 11 Latch Status Clear Status R W Note How to retrieve the counter frequency value on Modbus address mapping Example Counter dec value of 40002 x 65536 value of 40001 Frequency dec value of 40001 10 Hz ...

Страница 32: ...s connected Consult the dealer or an experienced radio TV technician for help This Transmitter must not be co located or operating in conjunction with any other antenna or transmitter Any changes or modifications including the antennas made to this device that are not expressly approved by the manufacturer may void the user s authority to operate the equipment This equipment complies with FCC RF r...

Отзывы: