WARNING ---
------------------------------------------------
When supplying power to this equipment, use the 3-pin connector provided, to connect to a
grounded power outlet
. If power is supplied without grounding to the equipment, there is a risk
of receiving a severe or fatal electric shock.
In the context of this document any voltage that is lethal is viewed as ‘High Voltage’. Therefore,
even prime power (90 to 264 V AC) is dangerous because prime power potentials have been
known to cause death or injury.
-----------------------------------------------
WARNING --
-------------------------------------------------
This equipment can not be repaired by the operator
. DO NOT attempt to remove the
equipment cover or to disassemble internal components. Only qualified service technicians
should service this equipment. There are high-voltage parts in this equipment presenting a risk of
severe injury to untrained personnel. In addition, there is a risk of damage to precision
components.
-----------------------------------------------
WARNING --
-------------------------------------------------
ALWAYS TERMINATE THE OUTPUT OF THE BLOCK UP-CONVERTER WITH A
RF LOAD CAPABLE OF DISSIPATING FULL CW RF POWER. SIMILARLY
TERMINATE THE INPUTS TO AVOID THE POSSIBILITY OF THE UNIT BEING
DRIVEN BY STRAY LEAKAGE SIGNALS.
Incorporate the terminations prior to applying
prime power to the unit. This procedure prevents self-oscillation and irradiation of the local
environment. Even if a source is not connected to the unit you are working with, there are
situations where the block up-converter can go into a self-induced mode and generate high levels
of RF energy. Destruction caused under excessive load voltage standing wave ratio (VSWR) will
void the warranty. Although this equipment has internal protection for VSWR higher than 3:1
and will automatically go in shutdown (with a delay of 1 second), still it is a safe procedure to
avoid unwanted effects.
7
Содержание SSPBM-K150-BRE
Страница 17: ...Figure 1 Product Outline 16 ...
Страница 36: ...Figure 4 HyperTerminal Mode Communication after pressing ENTER 35 ...
Страница 39: ...Figure 5 HyperTerminal Communication List of commands after pressing h ENTER for Help 38 ...
Страница 51: ...Figure 6 Proposed Graphic User Interface GUI based on RS 485 Protocol with no ALC set single unit 50 ...
Страница 52: ...Figure 7 Proposed Graphic User Interface GUI based on RS 485 Protocol with ALC set single unit 51 ...