NOTE:
All shadowed lines in the following table are for commands not applicable for single
units
TABLE 12
: COMPUTER TERMINAL COMMANDS FOR RS-232 INTERFACE
Command
Description
Response
h Help
function
Provides the list of commands that can be used to
modify the status of a unit.
<ENTER>
ENTER key of
keyboard
Provides and refreshes the main menu display on the
computer monitor screen.
alc
Automatic level
control
Allows for ALC set (on, off) and the ALC level set
alm Alarms
Displays the ALARMS of the unit (OK if no alarm)
csb
Cold Stby
Display and sets the cold stand-by (on, off)
cur Consumption
Displays the DC current consumption of the unit
dat Date(d:m:y)
Current date will be displayed (in format day : month:
year)
def Default
parameters
Set default parameters
elt Elapsed
Time
Elapsed functioning time
flt Faults
List of FAULTS
fpw Forward
PW
Displays the forward transmission output power (in
dBm)
lbp
Linearizer Bypass
Set the linearizer bypass (on, or off). Not used for these
units.
ltr
Low Power
Alarm/Fault
Threshold
Allows for the reading and the setting of the low output
power threshold as alarm or as fault (causing a
shutdown)
mac MAC
address
Displays and sets the Monitor and Control address
nam
Set unit name
Allows for a name to be attributed to the unit
pdo
Power Detector
Offset
Set an offset for the power detector, so that the detected
power will match the real output power of the unit at
different frequencies (between –3.0 and 2.0 dB)
psn
Unit position
Displays the position of the unit in the system (A or B)
rdt
Redundancy mode
Sets the Tx Redundancy mode (on/off) for redundant
systems
rpw Reflected
PW
Displays the reflected transmission power (in dBm)
39
Содержание SSPBM-K150-BRE
Страница 17: ...Figure 1 Product Outline 16 ...
Страница 36: ...Figure 4 HyperTerminal Mode Communication after pressing ENTER 35 ...
Страница 39: ...Figure 5 HyperTerminal Communication List of commands after pressing h ENTER for Help 38 ...
Страница 51: ...Figure 6 Proposed Graphic User Interface GUI based on RS 485 Protocol with no ALC set single unit 50 ...
Страница 52: ...Figure 7 Proposed Graphic User Interface GUI based on RS 485 Protocol with ALC set single unit 51 ...