Wiring

WARNING –

All  electrical  wiring  MUST  be  in  conformance  with  all

applicable local codes, regulations, and the National Electric Code (NEC).

Pump MUST be permanently connected to circuit. If other lights or appliances are
also on the same circuit, be sure to add their amp loads before calculating wire and

circuit breaker sizes. Use the load circuit breaker as the Master On-Off switch.

Time Clock

CAUTION –

Risk of equipment damage. 

Never run the booster pump without the filtration

system operating. Running the booster pump dry will damage the pump and void its warranty.

Installation of a separate time clock for the booster pump is recommended. Set timers so that the cleaner
turns on at least one half hour after the filtration system starts, and turns off at least one half hour before
the filtration system turns off. Time clocks for the filtration system and the booster pump must be
coordinated at all times to insure proper sequence of the filtration system and cleaner operations. If the
power to the time clocks is shut off or interrupted for any reason, the time clocks must be reset. A longer
than normal cleaning cycle is recommended for the first 30 days of operation. If an automatic control
system is used, please refer to the manufacturer’s installation guide.

START-Up & OpERATION

prior to Start-Up

WARNING –

All suction and discharge valves 

mUST be OpEN

, as well as filter manual air

relief valve (if available) on filter, when starting the circulating pump system for the first time, or after
servicing the system. Failure to do so could result in severe personal injury.

Starting the pump:

The filtration system pump must be running, and an automatic pool cleaner must be connected before
starting the booster pump. If water leakage occurs from anywhere on the pump or filter, immediately
tum off all system circulation pumps and all electrical power before repairing the leak. Do not return
to the pump or filter until all water flow has stopped. If no leakage occurs, stand at least 10 feet from
pump and/or filter and proceed with starting the pump.

WARNING –

Return to filter to close filter manual air relief valve when a steady stream of water

(not air or air and water mix) is discharged from valve. Failure to do so could result in severe personal injury.

CAUTION –

RISK OF EQUIpmENT DAmAGE.

Never operate the booster pump without

water. Water acts as a coolant and lubricant for the mechanical shaft seal. NEVER run pump dry.
Running pump dry may damage seals, causing leakage, flooding, and voids warranty. The filtration
system pump must be running before the booster pump is started. It is extremely important for the
booster pump to have an adequate water supply from the filtration system at all times. The booster
pump is not self-priming. To ensure that there is an adequate water supply for the booster pump:

9

INSTALLATION INSTRUCTIONS

Содержание PC34

Страница 1: ...s manual carefully and completely CAUTION We highly recommend a qualified professional install and service this product WARNING This manual contains important safety information that must be furnished to the end user of this product FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT IN SERIOUS INJURY SAVE THIS INSTRUCTION MANUAL PC34 OWNER S MANUAL INSTALLATION OPERATION PARTS ...

Страница 2: ...ode NEC ATTENTION INSTALLER ThIS mANUAL CONTAINS ImpORTANT INFORmATION ABOUT ThE INSTALLATION OpERATION AND SAFE USE OF ThIS pUmp ThAT mUST BE FURNIShED TO ThE END USER OFThIS pRODUCT FAILURE TO READAND FOLLOWALL INSTRUCTIONS COULD RESULT IN SERIOUS INJURY WARNING To reduce risk of injury do not permit children to use or climb on this product Closely supervise children at all times Components such...

Страница 3: ...onductor size 8 or larger Run a continuous wire from external bonding lug to reinforcing rod or mesh Connect a No 8 AWG 8 4 mm2 solid copper bonding wire to the pressure wire connector provided on the motor housing and to all metal parts of swimming pool spa or hot tub and to all electrical equipment metal piping except gas piping and conduit within 5 ft 1 5m of inside walls of swimming pool spa o...

Страница 4: ... all system valves must be set in a position to allow system water to return back to the pool Do not change filter control valve position while system pump is running Before starting system pump fully open filter manual air relief valve Do not close filter manual air relief valve until a steady stream of water not air or air and water mix is discharged from the valve All suction and discharge valv...

Страница 5: ...ump is exceptionally quiet and uses up to 40 less electricity than competitive booster pumps Pump design allows for easy installation and service Suitable for use with all pressure cleaners requiring a booster pump Tall mounting base allows for increased motor ventilation as well as protection from flooding Drain plug requires no tools for installation and removal Volute may be re oriented in the ...

Страница 6: ...clean Pump motors require free circulation of air for cooling pUmp mOUNTING Install pump on a level concrete slab or other rigid base to meet all local and national codes Secure pump to base with screws or bolts to further reduce vibration and stress on pipe or hose joints The base must be level rigid and vibration free pump mount must Allow pump inlet height to be as close to water level as possi...

Страница 7: ...strict flow For better efficiency use the fewest possible fittings but at least two suction outlets Avoid fittings that could cause an air trap Pool and spa fittings MUST conform to the InternationalAssociation of Plumbing and Mechanical Officials IAPMO standards Use a non entrapping suction fitting in pool multiple drains or double suction skimmer and main drain pipe Sizing Chart 7 INSTALLATION I...

Страница 8: ...ing on electrical connections Fire hazard match supply voltage to motor nameplate voltage Insure that the electrical supply available agrees with the motor s voltage phase and cycle and that the wire size is adequate for the HP kW rating and distance from the power source Use copper conductors only Voltage Voltage at motor mUST NOT be more than 10 above or below motor name plate rated voltage or m...

Страница 9: ...l suction and discharge valves mUST be OpEN as well as filter manual air relief valve if available on filter when starting the circulating pump system for the first time or after servicing the system Failure to do so could result in severe personal injury Starting the pump The filtration system pump must be running and an automatic pool cleaner must be connected before starting the booster pump If...

Страница 10: ...bearings and shaft seals No lubrication is necessary Keep motor clean Insure motor air vents are free from obstruction to avoid damage Do NOT use water to hose off motor Occasionally shaft seals must be replaced due to wear or damage See Shaft Seal Change Instructions in this manual Storage Winterization WARNING Separation hazard Do not purge the system with compressed air Purging the system with ...

Страница 11: ...fety precautions should always be observed including the following Failure to follow instructions may result in severe personal injury or death A WARNING To reduce risk of injury do not permit children to use this product B Disconnect all electrical power service to pump before beginning shaft seal replacement C Only qualified personnel should attempt rotary seal replacement Contact your local aut...

Страница 12: ...3 of this manual for pump component locations 7 Clean and lightly lubricate the motor shaft and seal recesses in the seal plate item 7 with a dilute solution of nongranulated liquid type soap Gently wipe the polished face of the ceramic seal with a soft cotton cloth Lubricate the rubber cup on the ceramic seat and press it firmly into the recess of the seal plate item 7 with the polished ceramic s...

Страница 13: ...ller 6 310108 Shaft Seal Assembly 7 310109 Seal Plate Assembly 8 310110 Nut 9 310111 Shaft Adapter 10 310112 Base Mounting Bolts 11 310113 Motor Support Base 12 310114 Motor Base Insulator 13 310115 Motor Insulator Ref No part No Description PARTS LIST FOR PC34 PUMP 3 4 5 6 1 2 7 9 10 11 8 12 13 ...

Страница 14: ...e the debris Low Flow Generally Check For 1 Clogged or restricted strainer or suction line Solution Contact a qualified repair professional 2 Undersized pool piping Solution Correct piping size 3 Plugged or restricted discharge line of filter valve partially closed high gauge reading Solution Sand filters backwash as per manufacturer s instructions D E filters backwash as per manufacturer s instru...

Страница 15: ...uct Incidental consequential or other damages will not be paid by Advantage Inc including but not limited to the cost of labor and or water or chemical loss or any damages that occur Damage cause by improper chemical treatment or corrosion Damage caused by Acts of God or nature Employment of the product for other than it s intended use Motor damage caused by improper electrical connections and or ...

Отзывы: