![Advantage Manufacturing PC34 Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/advantage-manufacturing/pc34/pc34_instruction-manual_3047872011.webp)
Storing pump For Winterization
WARNING –
To avoid dangerous or fatal electrical shock hazard, turn OFF
power to motor before draining pump. Failure to disconnect power may result in serious
personal injury or death.
1. Turn booster pump off before turning off the filtration system pump.
2. Turn the filtration system pump off.
3. Remove drain plug from seal plate (see Parts Diagram on page 13 of this manual for pump
component locations), and completely drain water from booster pump.
4. Winterize above and below ground piping in accordance with winterizing practices.
5. Refer to pressure cleaner owner's guide for cleaner system winterizing practices.
ShAFT SEAL ChANGE INSTRUCTIONS
ImpORTANT SAFETY INSTRUCTIONS
pLEASE READ AND FOLLOW ALL INSTRUCTIONS
When servicing electrical equipment, basic safety precautions should always be observed including
the following. Failure to follow instructions may result in severe personal injury or death.
A.
WARNING –
To reduce risk of injury, do not permit children to use
this product.
B. Disconnect all electrical power service to pump before beginning shaft seal
replacement.
C. Only qualified personnel should attempt rotary seal replacement. Contact your
local authorized Dealer or service center if you have any questions.
Exercise extreme care in handling both the rotating and the stationary sections of the two-part
replacement seal. Foreign matter or improper handling will easily scratch the graphite and ceramic
sealing surfaces.
Removing the motor Assembly
(See Parts Diagram on page 13 of this manual for pump component locations.)
1. Remove the six bolts and nuts which hold the volute (item #3) to the seal plate (item #7),
using a 1/2” wrench
2. Slide the motor assembly out of the volute (item #3), exposing the impeller (item #5).
11
INSTALLATION INSTRUCTIONS