Advantage Controls MICROtron MICRO-C Скачать руководство пользователя страница 14

14

VIII.  Manufacturer’s Product Warranty

 

Advantage Controls warrants units of its manufacture to be free of defects in material or workmanship.  Liability 

under this policy extends for 24 months from date of installation.  Liability is limited to repair or replacement of 

any failed equipment or part proven defective in material or workmanship upon manufacturer’s examination.  

Removal  and  installation  costs  are  not  included  under  this  warranty.    Manufacturer’s  liability  shall  never 

exceed the selling price of equipment or part in question.

Advantage disclaims all liability for damage caused by its products by improper installation, maintenance, 

use or attempts to operate products beyond their intended  functionality, intentionally or otherwise, or any 

unauthorized repair.   Advantage is not  responsible for damages, injuries or expense incurred through the 

use of its products.

The above warranty is in lieu of other warranties, either expressed or implied.  No agent of ours is authorized 

to provide any warranty other than the above.

30 Day Billing Memo Policy 

 

Advantage Controls maintains a unique factory exchange program to ensure uninterrupted service with 

minimum downtime.  If your unit malfunctions, call 1-800-743-7431, and provide our technician with Model 

and Serial Number information.  If we are  unable to diagnose and solve your problem over the phone, a fully 

warranted replacement unit will be shipped, usually within 48 hours, on a 30 Day Billing Memo.

This service requires a purchase order and the replacement unit is billed to your regular account for payment.

The replacement unit will be billed at current list price for that model less any applicable resale discount.  

Upon return of your old unit, credit will be issued to your account if the unit is in warranty.  If the unit is out of 

warranty or the damage not covered, a partial credit will be applied based upon a prorated replacement price 

schedule dependent on the age of the unit.  Any exchange covers only the controller or pump.  Electrodes, 

liquid end components and other external accessories are not included.

FCC Warning

This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in 

strict accordance with the manufacturer’s instruction, may cause interference to radio communications.  It has 

been type tested and found to comply with the limits for a class A computing device pursuant to subpart J of 

part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when 

operated in a commercial or industrial environment. Operation of this equipment in a residential area is likely 

to cause interference in which case the user, at his own expense, will be required to take whatever measures 

necessary to correct the interference.

Содержание MICROtron MICRO-C

Страница 1: ...tron MICRO C MICRO F4 Installation Maintenance Repair Manual Advantage Controls P O Box 1472 Muskogee OK 74402 Phone 918 686 6211 Fax 918 686 6212 www advantagecontrols com email support advantagecontrols com 07 2017 ...

Страница 2: ... 4 Electrode Installation 5 Cooling Tower Installation 5 IV Front Panel Description 6 V System Operation Overview 7 Description of SET UP Menu Screens 7 MICRO C Menu Map 8 MICRO F4 Menu Map 10 Conductivity Sampling Methods 12 A Continuous B Timed Sampling Calibration Overview 12 A Continuous B Timed Sampling VI Maintenance 13 VII Troubleshooting 13 VIII Warranty 30 Day Billing Memo Policy 14 ...

Страница 3: ...chemicals or the activation of other devices via a relay output MICRO C units include One totalizing water meter input that can be configured for contacting head or hall effect meter inputs Four mechanical relay outputs with normally open and normally closed contacts A manual relay timer that allows for manual activation of the relays for a user defined amount of time Conductivity Control C Conduc...

Страница 4: ...tage must be disconnected while making any connections If power is supplied to the unit line voltage will be present on the relay cards 3 Low voltage signal wires probes flow switch water meter etc should never be run in conduit with high voltage wires Logic and Relay Cards Logic Board Relay Power Board Rev D Ribbon Cable 2 1 10 9 POWER INPUT POWER SUPPLY Relay 1 Relay 2 Relay 3 Relay 4 Relay 5 5A...

Страница 5: ...ressure must be higher than outlet pressure in order for water to flow past the electrode s to achieve the required rate The probes are temperature compensated for increased accuracy NOTES 1 Install an isolation valve on either side of the flow assembly so electrodes can be easily isolated for removal and cleaning 2 A line strainer is recommended upstream from the probes to protect against fouling...

Страница 6: ...d to change the display from one line to the next Submenus will return to the top menu loop when all options are displayed ENTER Used to access menus and accept changed values CLEAR Used to clear numerical values being changed in SET UP mode BACK Used to move the cursor back when entering numerical values NUMBERS Used to enter new values in MENU mode ...

Страница 7: ...the up or down arrow to scroll through the various SET UP menus When you want to enter a specific SET UP menu press the ENTER key Once you have entered a SET UP sub menu you will be able to step through that menu s options with the down arrow key Relays may be forced on while in the SET UP mode Press the desired relay test key to force it on Press it a second time to turn it off The relay will act...

Страница 8: ...ed Cond Sc Recycle Off Time hh mm Run Time mm ss 28 Day Bio A All Days Cond Un A All Weeks Post Timer Post Timer of RUN 000 A Start 12 00a Zero Cond A Run Time hh mm Feed OK W A Prbld hh mm Timed Mode Interval hh mm A Lkout hh mm No Feed No Duration mm ss B All Days Setpoint 01500 B All Weeks Diff 0100 B Start 12 00a Direction Rise B Run Time hh mm High Alm 02500 B Prbld hh mm Low Alm 00600 B Lkou...

Страница 9: ...to prevent false contacts from water meter Set debounce to 0 for paddle wheel meters Reduce value if contacts are missed Default approx 500 0 32 767 scale Manual Relay Force Relay X Force ON OFF Timer mm ss Units Imperial eat for timers MICRO C Menu Map MICRO C units have a main menu circle that includes Calibration Calibrating the conductivity reading Bleed Set Setting the conductivity bleed set ...

Страница 10: ...ss 28 Day Bio A All Days A All Weeks A Start 12 00a A Run Time hh mm Feed OK W A Prbld hh mm A Lkout hh mm No Feed No B All Days B All Weeks B Start 12 00a B Run Time hh mm B Prbld hh mm B Lkout hh mm Units Imp Alarm List Scroll down to see all active alarms Repeat for other timers Post Timer Post Timer of RUN 000 ...

Страница 11: ...prevent false contacts from water meter Set debounce to 0 for paddle wheel meters Reduce value if contacts are missed Manual Relay Force Relay X Force ON OFF Timer mm ss Units Imperial peat for er timers t Timer RUN 000 MICRO F4 Menu Map MICRO F4 units have a main menu circle that includes Alarm List Displays all active alarms Timer Set Select the timer type and run values Configure Password flow ...

Страница 12: ...nds with a running average If a probe is quickly exposed from one extreme reading to another allow up to 30 seconds for the averaging to cycle and the current reading to stabilize MICROtron controller s conductivity scale should be selected so that the conductivity setpoint is as close as possible to the middle of the scale See page 9 menu for setting scale Note If a controller is using Timed Samp...

Страница 13: ...lat surface such as a bench top Sand electrode to remove stubborn deposits Do not wipe surface with your finger Oil from your skin will foul carbon tips 5 Reinstall the electrode in the system After the reading stabilizes calibrate the unit to a reliable test reading Many times an electrode can appear to be clean but the unit still cannot be calibrated If this is the case use one of the more aggre...

Страница 14: ...on If we are unable to diagnose and solve your problem over the phone a fully warranted replacement unit will be shipped usually within 48 hours on a 30 Day Billing Memo This service requires a purchase order and the replacement unit is billed to your regular account for payment The replacement unit will be billed at current list price for that model less any applicable resale discount Upon return...

Страница 15: ...15 ...

Страница 16: ...ment needs Cooling Tower Controllers Boiler Blow Down Controllers Blow Down Valve Packages Solenoid Valves Water Meters Chemical Metering Pumps Corrosion Coupon Racks Chemical Solution Tanks Solid Feed Systems Feed Timers Filter Equipment Glycol Feed Systems Pre Fabricated Systems Get the Advantage 5 4 3 2 1 ENTER HELP 5 4 3 CHANGE RUN SET UP 0 9 8 2 1 7 6 HOME BACK ...

Отзывы: