Installation Guide V1.2
6
CB7 SETUP
CB7 Setup for Rinnai units:
1. Ensure power to the air conditioner is OFF.
2. Connect Rinnai remote, then turn power ON.
3. Run unit in cooling / heating to test, then power OFF.
4. Disconnect the Rinnai remote from the indoor unit and replace with LINKSAM
cable. Connect the other end of the LINKSAM cable to the CB.
CABLE CORE COLOUR
INDOOR UNIT TERMINAL
RED
CN29-X
BLACK
CN29-Y
5. Go to Section 15 SYSTEM CONFIGURATION to complete install.
CB7 Setup for Haier units:
1. Ensure power to the air conditioner is OFF.
2. Connect Haier remote, then turn power ON.
3. Run unit in cooling / heating to test, then power OFF.
4. Follow Haier instructions and connect a YCJ-A002 Modbus adapter board
(supplied by Haier) to the indoor unit. Then connect the LINKSAM cable to the
CB and then wire the other end to the modbus board terminals.
CABLE CORE COLOUR
MODBUS BOARD TERMINAL
RED
CN1-A
BLACK
CN1-B
5. Go to Section 15 SYSTEM CONFIGURATION to complete install.
IMPORTANT:
1. The Standard Haier remote must be installed to provide temperature sensing.
2. MyZone functionality is not available for Haier units.
Содержание MyAir