background image

ZDW103 Instructions, Release 1.1

P/D 102406

HomePro

by ADVANCED CONTROL TECHNOLOGIES, INC.

0703-01

7

WARRANTY

For warranty and general product information visit our web site at www.act-solutions.com

ABOUT ZDW103’S CERTIFICATION

The ZDW103 has been thoroughly tested by the ETL SEMKO
division of Intertek, a nationally recognized testing laboratory.  This
product was found to be in compliance with safety standards  ANSI/
UL STD 1472 and CAN/CSA C22.2 No. 184.1.
In addition to compliance with product safety standards, the
ZDW103 is also certified to comply with applicable FCC and IC
rules and regulations governing RF and EMI emissions.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) This device must accept any interference received, including interference that may
cause undesired operation.

FCC NOTICE

Note:  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15
of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions may cause harmful interference to radio communications.  However, there is no guarantee
that interference will not occur in a particular installation.  If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:

-  Increase the separation between the equipment and receiver.
- Consult the dealer or an experienced radio/TV technician for help.

IC NOTICE

This Class B digital apparatus complies with Canadian ICES-003.

Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.

Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device
must accept any interference, including interference that may cause undesired operation of the device.

Содержание HomePro ZDW103

Страница 1: ...anada It is recommended that a qualified electrician perform this installation To reduce the risk of overheating and possible damage to other equipment do not install to control a receptacle a motor operated appliance a fluorescent lighting fixture or a transformer supplied appliance but only permanently installed incandescent lamp fixtures Make sure the lamp s to be controlled directly from the d...

Страница 2: ...ill then blink at a 1 second rate If another five minutes passes and the temperature is still too high the output power will be reduced to 10 The LED will then blink at a very fast rate Reduce the total wattage to avoid damage Local and Remote DIM BRIGHT Control of the load will not be available while in this state Local DIM BRIGHT control of the affected ZDW103 from associated Z Wave dimmers devi...

Страница 3: ...ands are ZDW103 will not respond to ALL ON or the ALL OFF command ZDW103 will respond to ALL OFF command but will not respond to ALL ON command ZDW103 will respond to ALL ON command but will not respond to ALL OFF command ZDW103 will respond to ALL ON and the ALL OFF command default Association The ZDW103 supports the Association command The ZDW103 can be set to control other Z Wave devices Those ...

Страница 4: ... The Dim command has a start level embedded in it A dimmer receiving this command will start dimming from that start level if this bit is set to 0 If the bit is set to 1 the dimmer will ignore the start level and instead start dimming from its current level Suspend Group 4 Parameter No 2 Length 1 Byte Valid Values 0 or 1 default 0 You may wish to disable transmitting commands to Z Wave devices tha...

Страница 5: ...m rate is when the dimmer is locally controlled Parameter 9 and 10 3 One set to control how fast the dim rate is when the dimmer receives an ALL ON or ALL OFF command Parameter 11 and 12 These values can be changed instantly to allow various scenes and effects The first of these parameters is the dim step dim rate parameter It can be set to a value of 1 to 99 This value indicates how many levels t...

Страница 6: ...e RF transmit power level of a node and test specific links between nodes with specific RF transmit power Refer to your controller s instructions if it supports this command for more information This command is typically used by professional installer SUC Support There must be a Static Update Controller in your Z Wave system for this feature to work A Static Controller is one that is not moved aft...

Страница 7: ...al device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interferen...

Отзывы: