ZDW103 Instructions, Release 1.1
P/D 102406
HomePro
by ADVANCED CONTROL TECHNOLOGIES, INC.
0703-01
4
Group 4
Only
associate
transmitters or controllers into Group 4. Group 4 should be used only to update a transmitter or
controller on the status of the ZDW103 which might have been controlled from another device.
You can
associate
up to
5
Z-Wave devices into
each
of these four groups. For instructions on how to “
associate
”
a Z-Wave device into one of these groups, refer to your wireless controller instructions. (If you are using the
ZTH100 controller, refer to the Setup Menu, Association section).
A note about dimming, if you combine Z-Wave enabled dimmers and other types of Z-Wave devices in a group,
place a Z-Wave enabled dimmer into the empty group 1
st
to ensure that the dimming operates correctly.
Configuration
The ZDW103 supports the Configuration command.
The ZDW103 can be configured to operate slightly differently than how it works when you first install it. Using the
Configuration command you can configure the following:
You can use a ZTH100 to send Configuration commands. (Refer to the Setup Menu, Configuration section)
Set Ignore Start Level Bit When Transmitting Dim Commands
• Parameter No: 1
• Length: 1 Byte
• Valid Values = 0 or 1 (default 1)
The ZDW103 can send Dim commands to Z-Wave enabled dimmers. The Dim command has a start level
embedded in it. A dimmer receiving this command will start dimming from that start level if this bit is set to 0. If
the bit is set to 1, the dimmer will ignore the start level and instead start dimming from its current level.
Suspend Group 4
• Parameter No: 2
• Length: 1 Byte
• Valid Values = 0 or 1 (default 0)
You may wish to disable transmitting commands to Z-Wave devices that are in Group 4 without “un-associating”
those devices from the group. Setting parameter 2 to the value of 1 will stop the ZDW103 from transmitting to
devices that are “associated” into Group 4.
It is possible that you may only want the units in Group 4 to track when the dimmer is being turned ON and OFF
and not when dimming.
Disable Group 4 During a Dim Command
•
Parameter 13
•
Length: 1 Byte
•
Valid Values = 0 or 1 (default 0)
After the ZDW103 is commanded to stop dimming, it will then command the Z-Wave devices in Group 4 to the
ZDW103’s new level. To prevent the ZDW103 from commanding the Z-Wave devices in Group 4 during this
particular occurrence, set Parameter 13 to the value of 1.
Night Light
• Parameter No: 3
• Length: 1 Byte
• Valid Values = 0 or 1 (default 0)
The LED on the ZDW103 will by default, turn ON when the load attached is turned ON. To make the LED turn ON
when the load attached is turned OFF instead, set parameter 3 to a value of 1.
Invert Switch
• Parameter No: 4
• Length: 1 Byte
• Valid Values = 0 or 1 (default 0)
To change the top of the switch to OFF and the bottom of the switch to ON, set parameter 4 to 1.