background image

 20 - FORM NO. 56041479 / ConvertaMAX

 34 / I-MAX

 34HD

INSTALLING THE BRUSHES OR PAD HOLDERS

1

Make sure the Brush Deck (14) is in the RAISED position.

2

If using pads, install the pads on the pad holders.

3

Place the brushes/pad holders under the raised Brush Deck (14).  NOTE:  brushes should be centered on the brush drive motors.

4

Turn the Master Key Switch (20) ON and push the Brush Install Button (35) to engage the brushes/pad holders.

NOTE:  Brushes can also be installed and removed by manually turning them onto or off of the brush drivers.

INSTALLING THE SQUEEGEE

1

Loosen the thumb screws on top of the squeegee tool.

2

Hold the squeegee tool so the curved ends point toward the front of the machine.

3

Slide the squeegee tool onto the squeegee mount.  Hand tighten the thumb screws - do not tighten them with a wrench or pliers.

4

Push the vacuum hose from the machine onto the vacuum tube on the squeegee.

FILLING THE SOLUTION TANK

Fill the solution tank with a maximum of 30 gallons (113 Liters).  Do not fill the solution tank above 7.5 cm (3 inches) from the top of the tank.  The solution should
be a mixture of water and the proper cleaning chemical for the job.  Always follow the dilution instructions on the chemical container label.

CAUTION !

Use only low-foaming, non-flammable liquid detergents intended for machine application.

WET SCRUBBING

1

Follow the instructions in the Preparing The Machine For Use section of this manual.

2

Turn the Master Key Switch (20) ON.  This will display the control panel indicator lights, reference the Battery Condition Indicator (17) and Hour Meter
(18).

3

Release the Operator Hand Brake (16).

4

Press the Solution Button (23) and hold for 5 seconds.  This is done to pre-wet the floor.  Note:  This will help prevent scarring of the floor surface when
starting to scrub with dry brushes.

5

Press the Normal Scrub Button (29) for moderate scrub deck pressure or the Heavy Scrub Button (27) for the highest pressure mode.  Note refer to the
machine control description section to the have more detailed explanation of this and other control panel functions.

6

When either the Normal Scrub Button (29) or Heavy Scrub Button (27) are selected, the brushes and squeegee automatically are lowered to the floor.
The machine’s scrub brushes rotation and solution system flow starts when the Drive Paddle (3) is activated.

7

When the Drive Paddle (3) is in the neutral position, the brushes do not run and solution is not dispensed.  Grip the Operator Control Handle (15) and
push the Drive Paddle (3) forward to start the brush motor and the solution, and to move the machine forward.  For best results, move the machine at
a slow walking speed.  Push the Solution Button (23) to turn the solution OFF while making sharp turns.  Pull the Drive Paddle (3) backward to move the
machine in reverse.  The brushes will run while moving the machine in reverse, and solution will be dispensed.

8

Begin scrubbing by moving the machine forward in a straight line at a normal walking speed and overlap each path by 2-3 inches (50-75 mm). Adjust when
necessary the machine speed and solution flow according to the condition of the floor.

9

Adjust the Solution Flow Control Knob (10) so a thin, even layer of solution can be seen in front of the Squeegee (8).  Note the adjustment can be changed
to allow variable solution flow for different types of floors to be scrubbed.  Example: A rough or absorbent floor surface, such as unfinished concrete, well
require more solution than a smooth finished floor.

CAUTION !

To avoid damaging the floor, keep the machine moving while the brushes are turning.

10

When scrubbing, check behind the machine occasionally to see that all of the waste water is being picked up.  If there is water trailing the machine, you
may be dispensing too much solution, the recovery tank may be full, or the squeegee tool may require adjustment.

11

For extremely dirty floors, a one-pass scrubbing operation may not be satisfactory and a “double-scrub” operation may be required.  This operation is the
same as a one-pass scrubbing except on the first pass the squeegee is in the up position (press the Vacuum Button (25) to raise the pick up squeegee).
This allows the cleaning solution to remain on the floor to work longer.  The final pass is made over the same area, with the squeegee lowered to pick
up the accumulated solution.

12

The recovery tank has an automatic float shut-off to prevent solution from entering the vacuum system when the recovery tank is full.  When the float shut-
off is activated, the control system will shut down the scrub, vacuum and solution systems.  The Vacuum System Fault Indicator (24) will be lit and the
Hour Meter / Status Display (18) will display “FULL”.  To clear the display, press the Scrub OFF Button (31).  When the float closes, the recovery tank
must be emptied.  The machine will not pick up water with the float closed.  NOTE:  If the control repeatedly gives a full indication when the tank is not
full, the automatic shut-off feature can be disabled, have a qualified service technician perform this function.

13

When the operator wants to stop scrubbing or the recovery tank is full, press the Scrub OFF Button (31) once.  This will automatically stop the scrub brushes
and solution flow and the scrub deck will raise UP.  NOTE:  the vacuum/squeegee system will not be turned off when the button is only pressed once,
this is to allow any remaining water to be picked up without turning the vacuum back on.  Press the button a second time and the squeegee will raise and
the vacuum will stop after a 10 second delay.

14

Move the machine to a designated waste water “DISPOSAL SITE” and empty the recovery tank.   To empty, remove the Drain Hose (5) from it’s hanger,
then remove the plug (hold the end of the hose above the water level in the tank to avoid sudden, uncontrolled flow of waste water).  Refill the solution
tank and continue scrubbing.

NOTE:  Make sure the Recovery Tank Cover (2) is properly seated or the machine will not pick-up water correctly.

Содержание ConvertaMAX 34

Страница 1: ...6041479 Advance MODELS 56397200 56397201 All models covered in this manual are OBSOLETE ConvertaMAX 34 before SN1593244 I MAX 34HD before SN1593246 ConvertaMAX 34 I MAX 34HD Instructions For Use Instr...

Страница 2: ...roller Error Codes 28 Technical Specifications 32 NDICE P gina Introducci n 3 Componentes y servicio 3 Placa de identificaci n 3 Desembalaje de la m quina 3 Precauciones y advertencias 5 Conozca su m...

Страница 3: ...piadora Autom tica Nilfisk Advance L alo con atenci n antes de utilizar la m quina Nota Los n meros que aparecen en negrita entre par ntesis se refieren a los elementos que aparecen en las ilustracion...

Страница 4: ...r stands to support the machine Do not dispense flammable cleaning agents operate the machine on or near these agents or operate in areas where flammable liquids exist Do not clean this machine with a...

Страница 5: ...baje nunca debajo de la m quina sin colocar antes bloques o soportes de seguridad en los que apoyar la m quina No aplique sustancias limpiadoras inflamables ni utilice la m quina sobre estas sustancia...

Страница 6: ...the text 1 Solution Tank Fill 2 Recovery Tank Cover 3 Drive Paddle 4 Solution Drain Hose Level Indicator 5 Recovery Drain Hose 6 Squeegee Adjustment Bolt not shown top of squeegee mount 7 Squeegee Bla...

Страница 7: ...t Indicator 23 Solution Button 24 Vacuum System Fault Indicator 25 Vacuum Button 26 Vacuum System Indicator 27 Heavy Scrub Button 28 Heavy Scrub Mode Indicator 29 Normal Scrub Button 30 Normal Scrub M...

Страница 8: ...isi n 4 Manguera de vaciado del l quido de limpieza Indicador de nivel 5 Manguera de vaciado del l quido recuperado 6 Pernodeajustedelaboquilla noapareceenlailustraci n parte superior de la pieza de l...

Страница 9: ...r de fallo del sistema de l quido 23 Bot n de l quido 24 Indicador de fallo del sistema de aspiraci n 25 Bot n de aspiraci n 26 Indicador del sistema de aspiraci n 27 Bot n de fregado intensivo 28 Ind...

Страница 10: ...s and counter clockwise to tilt it forward Squeegee Blade Latch 7 Holds rear squeegee blade and straps in place release to replace rear blade Squeegee 8 Picks up solution after scrubbing Battery Charg...

Страница 11: ...mentarily display the scrub pressure setting This is indicated by PA followed by a number Subsequent presses of the heavy scrub button will step the pad pressure setting through the allowable range up...

Страница 12: ...is indicator will be YELLOW if the vacuum squeegee system is in the AUTO mode and the Drive Paddle 3 is in the neutral position This indicates that the vacuum system is enabled but the vacuum is curre...

Страница 13: ...ator full charge down to 50 discharge Green Yellow Indicator 50 discharge down to 75 discharge Yellow Indicator 75 discharge down to 90 discharge Yellow Red Indicator 90 discharge down to 95 discharge...

Страница 14: ...reloj para inclinarla hacia delante Cierre del labio de goma de la boquilla 7 Mantiene colocados el labios posterior de la boquilla y las bandas bralo para cambiar el labio de goma posterior Boquilla...

Страница 15: ...talladeestadomostrar moment neamenteelvalordelapresi ndefregado queapareceindicadacomo PA seguida de un n mero Si sigue pulsando el bot n de fregado intensivo el valor de la presi n del disco ir aumen...

Страница 16: ...sulte la secci n Localizaci n de aver as Indicador del sistema de aspiraci n 26 Esteindicadorsepondr enAMARILLOsielsistemadeaspiraci n boquillaseencuentraenelmodoAUTO AUTOM TICO ylapalancadetransmisi...

Страница 17: ...descarga hasta 75 de descarga Indicador amarillo desde 75 de descarga hasta 90 de descarga Indicador amarillo y rojo desde 90 de descarga hasta 95 de descarga Indicador rojo desde 95 de descarga hast...

Страница 18: ...hatdelivered them or the battery manufacturer to file a damage claim 2 Turn the Master Key Switch 20 OFF and remove the key 3 Tip the recovery tank to the side locked position Remove the battery cable...

Страница 19: ...abricante de las bater as para presentar una reclamaci n por da o 2 Sit e el interruptor de llave principal 20 en posici n OFF APAGADO y retire la llave 3 Incline el dep sito de recuperaci n hacia un...

Страница 20: ...will be dispensed 8 Beginscrubbingbymovingthemachineforwardinastraightlineatanormalwalkingspeedandoverlapeachpathby2 3inches 50 75mm Adjustwhen necessary the machine speed and solution flow according...

Страница 21: ...e pondr n en funcionamiento los cepillos y comenzar a salir el l quido 8 Empiece la operaci n de fregado moviendo la m quina hacia delante en l nea recta a la velocidad del paso normal Cada recorrido...

Страница 22: ...ff the elbow Direct the hose to a designated DISPOSAL SITE Rinse the tank with clean water Inspect the solution hoses replace if kinked or damaged 4 To empty the recovery tank take the Recovery Drain...

Страница 23: ...MINACI N Aclare el dep sito con agua limpia Examine las mangueras para el l quido y c mbielas si est n retorcidas o da adas 4 Paravaciareldep sitoderecuperaci n retirelamangueradedesag ederecuperaci n...

Страница 24: ...king soda to 1 litre of water LUBRICATING THE MACHINE Once a month apply light machine oil to lubricate the drive chain all pivot points SERVICING THE VACUUM MOTOR Have your Nilfisk Advance Dealer che...

Страница 25: ...r 1 litro de agua LUBRICACI N DE LA M QUINA Una vez al mes aplique aceite ligero a la m quina para la lubricaci n de la cadena de impulsi n todos los puntos de pivotaje MANTENIMIENTO DEL MOTOR DE ASPI...

Страница 26: ...ving machine too fast Slow down Not using enough solution Adjust solution control valves Inadequate solution flow Solution tank empty Fill solution tank or no solution Solution lines valves filter clo...

Страница 27: ...uzca la velocidad Aplicaci n de l quido insuficiente Ajuste las v lvulas de control del l quido Flujo de l quido inadecuado Dep sito de l quido vac o Llene el dep sito de l quido o falta de l quido Tu...

Страница 28: ...service manual 8 Scrub motor severe overload See error code 7 Bad electrical connection Check all conections to scrub motors Defective scrub motor s Consult service manual 9 Scrub motor circuit open...

Страница 29: ...vice manual Solenoid failure Consult service manual 32 Solution solenoid overload Control failure Consult service manual 33 Solution solenoid severe overload See error code 32 Bad electrical connectio...

Страница 30: ...cio 8 Sobrecarga grave del motor de depuraci n Ver el c digo de error 7 Mala conexi n el ctrica Comprobar todas las conexiones a los motores de depuraci n Motor es de depuraci n defectuoso s Consultar...

Страница 31: ...32 Sobrecarga del solenoide de soluci n Fallo de control Consultar el manual de servicio 33 Sobrecarga grave del solenoide de soluci n Ver el c digo de error 32 Mala conexi n el ctrica Comprobar todas...

Страница 32: ...batteries full tank lbs kg 1350 612 1435 651 Vibrations at the Hand Controls m s2 2 5m s2 2 5m s2 ESPECIFICACIONES T CNICAS instaladas y comprobadas en la unidad Modelo ConvertaMAX 34 I MAX 34HD N de...

Страница 33: ...Nilfisk Advance Inc 14600 21st Avenue North Plymouth MN 55447 3408 www nilfisk advance com Phone 800 989 2235 Fax 800 989 6566 2002 Nilfisk Advance Inc Plymouth MN 55447 3408 Printed in the U S A...