Trouble
Possible Cause
Remedy
No motor ignition
The power supply cable (21) is faulty or
disconnected from the electrical mains
Replace the cable or connect it
Insuf
fi
cient dirty water vacuuming
The recovery tank (26) is full
Empty
The vacuum grid (36) is clogged or the
fl
oat is
stuck closed
Clean the grid and check the
fl
oat
Vacuum hose (22) disconnected from the
squeegee (11) or faulty
Connect
The squeegee (11) is dirty or the squeegee
blades (13, 14) are worn or damaged
Clean the squeegee or replace the blades
The recovery tank cover (6) is not properly
closed, or the gasket (32) is damaged
Check and/or clean the seating surface or
replace the gasket
Dirty recovery tank (6) (clogged drain hole)
Clean
Insuf
fi
cient solution
fl
ow to the brush/pad
Dirty solution
fi
lter (20)
Clean
The squeegee leaves marks on the
fl
oor
Debris under the squeegee blades (13, 14)
Remove the debris
Worn, chipped or torn squeegee blades (13,
14)
Replace the blades