29
2.1 Position of the stove / distance requirements
Distance requirements will only apply if the wood burning stove is to be placed close to flammable materials:
Distance to flammable
material (cm)
To the sides
(A)
Behind the
stove (B)
Distance to
furniture (C)
Corner
position (D)
Above the
stove
Aduro 14
25
7
100
8
50
Aduro 15
11 to the side up to the door
and hereafter 34
12
120
-
50
Aduro 15.2
11 to the side up to the door
and hereafter 34
12
120
-
50
Aduro 15.3
11 to the side up to the door
and hereafter 34
12
120
-
50
Aduro 19
30
10
85
-
50
Aduro 21
50 to the side up to the side
glass and hereafter 65
17.5
120
-
50
If the stove is positioned against a brick wall or other non-flammable material, there are no minimum distance
requirements. To facilitate cleaning and for the best use of the convection air, we recommend that you keep
a distance of approximately 5-10 cm to the wall.
If the wood burning stove is to be placed on a flammable material (or above flammable material for Aduro
15.3) such as a wooden floor or carpet, it must be placed on a non-flammable floor hearth. The floor hearth
should extend for at least 30 cm in front of the stove and 15 cm on each side measured from the opening of
the combustion chamber.
A
B
C
D
D
A
D
The wood burning stove must be installed on a floor with the adequate load-
bearing capacity. If the existing construction does not meet this requirement,
appropriate adaptation measures must be taken (e.g. a load-distributing plate).