background image

7

61291004L2-5, Issue 2

61291004L2-5B

Remote End Initiated LBK Tests

The TRDDB  supports loopbacks generated from the
TROCU-R which allow testing to be performed
without coordination with the CO or test center.
These loopbacks, initiated by the TROCU-R front
panel LBK pushbutton aid in system turn-up testing or
troubleshooting from the remote end.

The TRDDB responds to a loopback command
initiated at the TROCU-R as follows:

Pressing the LBK pushbutton once will initiate a
loopback at the TRDDB towards the customer.  See

Figure 9

.  This allows data to be sent from the remote

end to test the local loop and the TROCU-R.

Pressing the LBK pushbutton a second time initiates a
loopback at the TROCU-R towards the 4-wire DDS
(CPE) interface. See 

Figure 10

.  Pressing the LBK

pushbutton a third time disables all current latching
loopbacks initiated by the LBK pushbutton.

If errors exist the loopbacks can help determine the
source; either the local loop or the TROCU-R. During
a remote end initiated loopback the Total Reach
system transmits ASC 9Eh towards the network
indicating an out-of-service condition generated by
the remote end as seen in Figure 9 and Figure 10.

All Total Reach system latching loopbacks, whether
initiated by the craft interface, LBK pushbutton, or via
the Test Center or CO, may be disabled by sending 35
TIP bytes <X0111010> where X is a “don’t care”. All
existing latching loopbacks may also be disabled by
pressing the LBK pushbutton on the CO or remote
units.

4. REMOTE PROVISIONING AND

DIAGNOSTICS

Control Protocol

Remote access to provisioning and status information
is accomplished using ADTRAN Digital System 6
Message protocol, defined in Control and Diagnostic
Procedures Practice, Section 6032991-6.  Digital
System 6 is supported by the TPI 108/109 and 105
portable test set and is supported by Hekimian React
2001 Release 1.900 remote test system.  The Total
Reach DDS network elements comply with ANSI
T1.107-1995,  “ Digital Hierarchy Format
Specifications Annex G ” which allows remote
provisioning, querying, and performance monitoring
via in-band control of network elements.

NOTE

The REACT 2001 GUI software Release
supports ANSI T1.107-1995.

Figure 10.  TROCU-R Remote End Initiated Loopback, Customer Loop

Figure 9.  TROCU-R Remote End Initiated Loopback, Local Loop

4-Wire

CPE Interface

TR

OCU-R

Push once for Total Reach

DDB Loopback

Local Loop

ASC 9Eh

TR

DDB

Loopback
Pushbutton

Test

Set

4-Wire

CPE Interface

TR

OCU-R

Push twice for Total Reach

OCU-R Loopback

Local Loop

ASC 9Eh

TR

DDB

Loopback
Pushbutton

Test

Set

ASC 9Eh

Содержание Total Reach TRDDB

Страница 1: ...NSTALLATION 2 3 TESTING 5 4 REMOTE PROVISIONING AND DIAGNOSTICS 7 5 DEPLOYMENT GUIDELINES 8 6 MAINTENANCE 9 7 WARRANTY AND CUSTOMER SERVICE 9 FIGURES Figure 1 Total Reach DDB 1 Figure 2 DS0 Level Test Access for DDS Customers w 2 End Points Served from Same CO 2 Figure 3 Multipoint DDS Deployment 3 Figure 4 Back Hauled IXC T1 to DDS 3 Figure 5 Connector Pin Assignments 3 Figure 6 Rate Selection an...

Страница 2: ...ons NEAR and FAR logic level Bantam test access Loop Quality Monitor and latching loopback Description The ADTRAN D4 TRDDB is a 2 wire Total Reach DDS functional replacement for the following ADTRAN 4 wire OCU part numbers 1104004L3 D4OCBRD2AA 1104004L4 D4OCBRE2AA 1105004L1 D4OCBSD2AA 1105004L2 D4OCBSE2AA 1105018L1 D4OCBTD2AA The TRDDB delivers data at rates up to 64 kbps using a single copper pai...

Страница 3: ... Figure 5 for pinout assignments Code Input Output Power Code PC F C Telecommunication Code TC X Installation Code IC A Table 1 Compliance Codes Figure 5 Connector Pin Assignments Figure 4 Back Hauled IXC T1 to DDS DS0 DS0 IXC T1 DS0 DP TR OCU R DSU CSU GPC D4 or SLC96 TR DDB Test Head 2 wire Loop 50 kft Customer Premises CO Figure 3 Multipoint DDS Deployment DS0 DS0 DS0 DS0 DS0 IXC T1 DS0 DP MJU ...

Страница 4: ...DTRAN s Protected Loopback mode Protected Loopback ADTRAN s Protected Loopback supports the DDS latching loopback standard in T1E1 2 99 007R1 When enabled the TRDDB will respond to latching loopback when the idle code preamble is sent prior to the latching loopback sequence specified in TR62310 and ANSI T1 417 See Table 3 for the latching loopback sequence requirement when Protected Loopback is en...

Страница 5: ... 1 C I P e g u a G 2 2 2 1 9 0 8 5 2 0 1 5 1 0 1 1 F 0 P L U P e g u a G 2 2 F 0 7 P L U P e g u a G 2 2 F 0 2 1 P L U P e g u a G 2 2 4 5 4 9 0 6 0 6 0 1 0 7 3 1 1 F 0 C I P e g u a G 4 2 F 0 7 C I P e g u a G 4 2 F 0 2 1 C I P e g u a G 4 2 1 7 5 2 1 2 8 9 3 1 7 1 9 4 1 F 0 P L U P e g u a G 4 2 F 0 7 P L U P e g u a G 4 2 F 0 2 1 P L U P e g u a G 4 2 0 0 9 2 1 4 2 3 4 1 8 6 2 5 1 F 0 C I P e g...

Страница 6: ... t y B d e v i e c e R s e t y B d e v i e c e R s e t y B d e v i e c e R s e t y B d e v i e c e R s e t y B d e v i e c e R g n i t s i x e r a e l C s k c a b p o o l e c i v e d y f i t n e d I d e p o o l e b o t p o o l o t e r a p e r P e d o c P A M d n e s s e t y b 0 3 r e t f a e t a v i t c A k c a b p o o l n i n o i t i s n a r T P I T s s e r g o r p 0 1 0 1 1 1 0 X t c e l e s k c...

Страница 7: ...al Reach system latching loopbacks whether initiated by the craft interface LBK pushbutton or via the Test Center or CO may be disabled by sending 35 TIP bytes X0111010 where X is a don t care All existing latching loopbacks may also be disabled by pressing the LBK pushbutton on the CO or remote units 4 REMOTE PROVISIONING AND DIAGNOSTICS Control Protocol Remote access to provisioning and status i...

Страница 8: ...rmation stored in 15 minute and 24 hour registers for both the TRDDB and TROCU R and an event log which time stamps system performance anomalies and threshold violations Physical access to the terminal interface on the TROCU R is made by a serial interface connection to a dumb terminal or dumb terminal emulation Provisioning of the TRDDB can be viewed and changed from the terminal interface on the...

Страница 9: ...cy and Procedure document 60000087 10A Contact Customer and Product Service CAPS prior to returning equipment to ADTRAN For service CAPS requests or further information contact one of the following numbers ADTRAN Sales Pricing Availability 800 827 0807 ADTRAN Technical Support Presales Applications Postsales Technical Assistance 888 726 8663 Standard hours Monday Friday 7 a m 7 p m CST Emergency h...

Страница 10: ...10 61291004L2 5 Issue 2 61291004L2 5B ...

Отзывы: