Alarm Processing

The SCU monitors the status of each line card and
provides necessary alarm processing to determine the
overall alarm state of the system.

Alarm Outputs

The SCU determines alarm states and reports these
results via onboard alarm interfaces and through
active user access channels. Each onboard alarm
interface consists of Form-C relay contacts to provide
Common (COM), Normally Open (NO), and
Normally Closed (NC) functionality. Physical access
to the relay contacts is attained by way of wire-wrap
posts per alarm function.  These posts are located on
the rear panel of the Total Access 1500 shelf. The
following alarm outputs are supported:

Alarm

Wire-wrap Header

• Major Audible

MAJ-A

• Minor Audible

MIN-A

• Major Visual

MAJ-V

• Minor Visual

MIN-V

The SCU provides front panel LEDs (See Table 2) to
indicate the status of the shelf and Alarm Cut Off
(ACO) state.

Alarm Inputs

The SCU supports external alarm, status, or control
inputs.  Circuitry on the SCU accepts a -48V signal as
an active state. Physical access to these inputs is
attained by way of two wire-wrap posts per input
function located on the rear panel of the Total Access
1500 shelf. The following alarm inputs are supported:

Alarm

Wire-wrap Header

• Auxiliary 1

AUX 1

• Auxiliary 2

AUX 2

• Alarm Cut Off

AUX 3

• Remote

AUX 4

NOTE

The front panel mounted ACO switch is used to
cut off an alarm.

Configuring Alarms

To configure alarms the user will need to perform the
following:

1. Logon to the system.

2. From the Total Access 1500 main menu, select

option 1, System Controller, and press ENTER.

3. From the System Controller menu, select option

4, Alarms, and press ENTER.

4. Provision the alarms as desired.

The following items may be configured:

• Alarm Relay Mapping – allows the user to select

T1 or D4 alarm relay mapping

• Log MLT Alarms – enables/disables the logging

of MLT alarms

• Ringer Alarms – enables/disables ringer alarms

• AUX1 Alarm – enables/disables AUX1 alarm

input

• AUX2 Alarm – enables/disables AUX2 alarm

input

• RMT Alarm – enables/disables RMT alarm input

• Primary Power Alarm – enables/disables alarm

condition associated with having primary power
feed removed

• Secondary Power Alarm – enables/disables alarm

condition associated with having secondary
power feed removed

• PSU Configuration – choose single or dual PSU

according to whether redundant equipment is
installed in the Total Access 1500 chassis

• LIU Configuration – choose single or dual LIU

according to whether redundant equipment is
installed in the Total Access 1500 chassis

Содержание Total Access 1500 SCU

Страница 1: ...ry This is the second release of this document This version includes updates describing TL1 over X 25 and TCP IP Features The Total Access 1500 SCU P Ns 1180008L1 1180008L2 and 1180008L3 includes the...

Страница 2: ...static packing material when transporting or storing The Total Access 1500 SCU plugs directly into the SCU slot in the common module area of the Total Access 1500 chassis WARNING TheTotalAccess1500SCU...

Страница 3: ...m r e T a t a D R T D 5 d n u o r G l a n g i S X 25 Port The SCU supports synchronous RS 232 compatible serial interface to be used in conjunction with an X 25 network The unit includes PAD functions...

Страница 4: ...session or a Telnet session VT100 Terminal To connect either a terminal or a PC emulating a terminal to the craft port 1 Set the parameters of the VT100 terminal to 9600 baud rate NOTE The SCU craft...

Страница 5: ...m the Management Configuration menu select option 1 IP Address and press ENTER NOTE The IP Address Subnet Mask and Gateway are in the form XXX XXX XXX XXX with the XXX s representing 1 2 or 3 digit de...

Страница 6: ...32 shelves may be clustered together via the RS 485 bus To set up RS 485 chaining perform the following 1 Give the first SCU in the chain a unique Target ID TID 2 Enable RS 485 Interface 3 Set Interba...

Страница 7: ...Local 1 SCU 2 Online LIU 1 Select Y Modem Upload Destination 3 Modify Checksum 2 Start Y Modem Upload 5 Reset the Y Modem Destination 4 Compute Checksum and Store Unit Name Part Number CLEI Code Prod...

Страница 8: ...the Total Access 1500 shelf The following alarm inputs are supported Alarm Wire wrap Header Auxiliary 1 AUX 1 Auxiliary 2 AUX 2 Alarm Cut Off AUX 3 Remote AUX 4 NOTE The front panel mounted ACO switc...

Страница 9: ...m u H e v i t a l e R g n i s n e d n o c n o n C 0 5 m u m i x a m 5 9 n o i t a p i s s i D t a e H m u m i x a m s t t a w 4 2 4 e c n a i l p m o C 0 5 9 1 L U 3 l e v e L S B E N E R O C 9 8 0 1...

Страница 10: ...mer and Product Service CAPS prior to returning equipment to ADTRAN For service CAPS requests or further information contact one of the following numbers ADTRAN Sales Pricing Availability 800 827 0807...

Отзывы: