Figure 2.  System Controller Menu Tree

1.

 Configur

ation

2.

 Pro

visioning

3.

 T

est

4.

 Alar

ms

5.

 Management Configur

ation

6.

 Secur

ity

User

names (1-16)

1.

 User Name

2.

 P

ass

w

ord

3.

 R/W

4.

 T

est

5.

 Admin

6.

 Delete 

This User

Enter Ne

w User Name

Enter Ne

w P

ass

w

ord

1.

 Read-Only

2.

 Read/Wr

ite

1.

 Disab

led

2.

 Enab

led

1.

 IP Address

2.

 IP Subnet Mask

3.

 IP Def

ault Gate

w

a

y

4.

 TELNET P

o

rt

 Number

Enter V

alue

5.

 TCP/IP P

o

rt

 Number

6.

 SNMP Configur

ation

Enter 

V

alue (1024 ..

 9999)

1.

 Disab

led

3.

 Major

2.

 Minor

1.

 Disab

led

2.

 Enab

led

1.

 Disab

led

2.

 Enab

led

1.

 Disab

led

2.

 Enab

led

1.

 Dual PSU

2.

 Single PSU

1.

 T1 

Mapping

2.

 D4 Con

v

entional

1.

 F

orce LIU F

ailo

v

e

r

2.

 SCU Reset

1.

 Alar

m Rela

y Mapping

2.

 Log ML

T Alar

ms

3.

 Ringer Alar

ms

4.

 A

UX1 Alar

m

1.

 Disab

led

2.

 Enab

led

5.

 A

UX2 Alar

m

6.

 RMT Alar

m

9.

 PSU Configur

ation

1.

 None

Enter Ne

w P

ass

w

ord

Enter V

alue

2.

 Local

1.

 SCU

2.

 Online LIU

1.

 Select 

Y

-Modem Upload Destination

3.

 Modify Chec

ksum

2.

 Star

Y

-Modem Upload

5.

 Reset the 

Y

-Modem Destination

4.

 Compute Chec

ksum and Store

Unit Name

P

a

rt

 Number

CLEI Code

Product Re

vision

Softw

are Re

vision

MA

C Address

1.

 Disab

led

2.

 Enab

led

1.

 T

e

rminal 

A

uto-Logout

2.

 A

uto-Logout 

Time

1.

 Disab

led

2.

 Enab

led

1.

 Date

Enter V

alue

Enter V

alue 

(1...60)

3.

 T

e

rminal 

A

uto-Logout

4.

 P

ass

w

ord A

uthentification

5.

 P

ass

w

ord

6.

 T

arget ID (TID)

7.

 RS-485 Interf

ace

1.

 Client

2.

 Host

1.

 MT

A Mode

2.

 ML

T Mode

8.

 Interbank Comm

unication Mode

9.

 Y

-Modem 

Application

10.

 T

est Access Mode

2.

 Time

11.

 Cr

aft P

o

rt

 Baud Rate

1.

 Er

ase SCU

2.

 Cancel

Enter Ne

w Chec

ksum

1.

 9600

2.

 38400

7.

 A

CO Alar

m

8.

 SLC-96 Pwr/Misc Alm (CO

T Only)

10.

 LIU Configur

ation

1.

 Dual LIU

2.

 Single LIU

1.

 SNMP A

uthentication 

T

raps

2.

 Read-Only Comm

unity Name

3.

 Read-Wr

ite Comm

unity Name

4.

 System Contact

5.

 System Name

6.

 System Location

7.

 SNMP 

T

rap Hosts

8.

 Re-Map Interf

ace Indices

1.

 Disab

led

2.

 Enab

led

Enter V

alue

T

rap Host 1-8

1.

 IP Address

2.

 Status

1.

 Enab

led

2.

 Disab

led

Enter IP Address

Содержание Total Access 1500 SCU

Страница 1: ...ry This is the second release of this document This version includes updates describing TL1 over X 25 and TCP IP Features The Total Access 1500 SCU P Ns 1180008L1 1180008L2 and 1180008L3 includes the...

Страница 2: ...static packing material when transporting or storing The Total Access 1500 SCU plugs directly into the SCU slot in the common module area of the Total Access 1500 chassis WARNING TheTotalAccess1500SCU...

Страница 3: ...m r e T a t a D R T D 5 d n u o r G l a n g i S X 25 Port The SCU supports synchronous RS 232 compatible serial interface to be used in conjunction with an X 25 network The unit includes PAD functions...

Страница 4: ...session or a Telnet session VT100 Terminal To connect either a terminal or a PC emulating a terminal to the craft port 1 Set the parameters of the VT100 terminal to 9600 baud rate NOTE The SCU craft...

Страница 5: ...m the Management Configuration menu select option 1 IP Address and press ENTER NOTE The IP Address Subnet Mask and Gateway are in the form XXX XXX XXX XXX with the XXX s representing 1 2 or 3 digit de...

Страница 6: ...32 shelves may be clustered together via the RS 485 bus To set up RS 485 chaining perform the following 1 Give the first SCU in the chain a unique Target ID TID 2 Enable RS 485 Interface 3 Set Interba...

Страница 7: ...Local 1 SCU 2 Online LIU 1 Select Y Modem Upload Destination 3 Modify Checksum 2 Start Y Modem Upload 5 Reset the Y Modem Destination 4 Compute Checksum and Store Unit Name Part Number CLEI Code Prod...

Страница 8: ...the Total Access 1500 shelf The following alarm inputs are supported Alarm Wire wrap Header Auxiliary 1 AUX 1 Auxiliary 2 AUX 2 Alarm Cut Off AUX 3 Remote AUX 4 NOTE The front panel mounted ACO switc...

Страница 9: ...m u H e v i t a l e R g n i s n e d n o c n o n C 0 5 m u m i x a m 5 9 n o i t a p i s s i D t a e H m u m i x a m s t t a w 4 2 4 e c n a i l p m o C 0 5 9 1 L U 3 l e v e L S B E N E R O C 9 8 0 1...

Страница 10: ...mer and Product Service CAPS prior to returning equipment to ADTRAN For service CAPS requests or further information contact one of the following numbers ADTRAN Sales Pricing Availability 800 827 0807...

Отзывы: