61245023L1-5B

Section 61245023L1-5B, Issue  2

5

2.  INSTALLATION
Unpacking and Inspection

After unpacking the unit, inspect it for damage.  If
damage is discovered, file a claim the carrier, then
contact ADTRAN.  See 

Warranty and Customer

Service

.

Configuring the T1 Nx64 HTU-R

The T1 Nx64 HTU-R contains options used to
properly configure the unit.  These configuration
options are accessible through the front panel LCD
and push buttons.  The T1 Nx64 HTU-R
configuration options are shown in 

Table 2.

Table 2.  Configuration Options for a Remote (Slave) Unit

Configuration

Description

HTU-R Mode

Selects between Master and Slave mode for the T1 Nx64 HTU-R

Master (HTU-C) ........... The T1 Nx64 HTU-R is configured as the Local (Master) unit
Slave (HTU-R) ............. The T1 Nx64 HTU-R is configured as the Remote (Slave) unit

Clock

Selects the HDSL timing source

Network ........................ The T1 Nx64 HTU-R will derive HDSL timing from the network
Internal ......................... The T1 Nx64 HTU-R uses its internal oscillator to generate HDSL

timing

DTE .............................. The T1 Nx64 HTU-R derives HDSL timing from the DTE

DTE INT. TYPE

Selects the DTE interface connector being used

V.35 ............................... Select this option if the DTE is connected to the M/34 connector
V.11 ............................... Select this option is the DTE is connected to the DB11 connector

RATE 56/64

Selects the channel data rate of either 56 kbps or 64 kbps

56 .................................. Selects 56 kbps
64 .................................. Selects 64 kbps

CHANNELS

Selects between contiguous or alternating DS0s

CONT ........................... Contiguous DS0s
ALT ............................... Alternating DS0s

DTE TX CLK

Selects the timing source for the transmit data clock

INT_INV ...................... Inverted form of the internal DTE-TX-CLK setting
AUTO ........................... Measures the delay between the DTE  data and its clock and

automatically selects between INTERNAL and INT_INV

INTERNAL .................. Allows the Nx64 HTU-R to provide transmit data clock
EXTERNAL ................. Derives DTE transmit clock from the DTE device

START CHAN

Selects the starting channel (01 thru 24) for Nx56/64 kbps operation

# OF CHAN.

Selects the number N (01 thru 24) for Nx56/64 kbps operation

DATA

Controls the state of the TD and RD leads

NORMAL ..................... Forces normal data format
INVERT ....................... Forces inverted data format

CTS

Controls the state of the CTS lead from the HTU-R

NORMAL ..................... Causes CTS to follow RTS
FORCE ON .................. Causes CTS to be forced on and RTS ignored

DCD

Controls the state of the DCD lead from the HTU-R

NORMAL ..................... DCD is active when loops are in sync and/or when a T1 carrier is present
FORCE ON .................. Causes DCD to be forced on always

DSR

Controls the state of the DSR lead from the HTU-R

NORMAL ..................... Causes DSR to follow DTR
FORCE ON .................. Causes DSR to be forced on and DTR ignored

Содержание T1 Nx64 HTU-R

Страница 1: ...se this product near water for example near a bathtub washbowl sink or laundry tub in a wet basement or near a swimming pool 2 Avoid using this or other telephone equipment other than the cordless typ...

Страница 2: ...he circuit The rear panel of the T1 Nx64 HTU R has all the connections for the HDSL local loop the Customer Premises Equipment CPE power and console port The T1 Nx64 HTU R connects to the HDSL local l...

Страница 3: ...Y AA Pin Number 1 19 20 37 7 9 12 13 4 6 22 24 17 8 35 26 5 23 25 27 30 31 Signal Name Frame Ground Signal Ground Rx Common Tx Common RTS CTS DTR DSR TxD A RxD A TxD B RxD B Ext TxC A RxC A Ext TxC B...

Страница 4: ...Blinking An error detected on either end of Loop 2 will cause this LED to blink briefly Indicates an alarm condition at the local or remote HDSL unit Off No alarm condition detected Red Local alarm co...

Страница 5: ...V 11 Select this option is the DTE is connected to the DB11 connector RATE 56 64 Selects the channel data rate of either 56 kbps or 64 kbps 56 Selects 56 kbps 64 Selects 64 kbps CHANNELS Selects betw...

Страница 6: ...tenance Practice and proceed to Step 4 Step 3 Configure the second T1 Nx64 HTU R as a Master unit To properly configure the T1 Nx64 HTU R the user must configure the HDSL interface options concerning...

Страница 7: ...n 7 and 9 for an error free circuit Any signal quality indication less than 7 indicates the possibility of bit errors The Loop Loss value can be displayed by executing the following procedure Scroll b...

Страница 8: ...meters are measured and displayed for the HDSL interface These parameters are available for both Loop 1 and Loop 2 These parameters are SIGNAL QUALITY LOOP LOSS and LOOP SYNC SIGNAL QUALITY This measu...

Страница 9: ...enu In order to gain access to the unit unlock the Keypad option and enter the correct passcode V 54 Loopback This option is located under the Remote feature of the Loopbacks option of the Test menu T...

Страница 10: ...hnical Support Normal Support Hours 7am 7pm CST or Emergency Support Hours 7x24 Voice Toll Free 800 726 8663 Fax 256 963 6217 Voice 256 963 8100 Internet www adtran com HTU C INFORMATION SIGNAL QUALIT...

Страница 11: ...oise Margin 0 Poor 0 dB 10 7 BER 1 8 Marginal above 10 7 BER in dB 9 Excellent 9 dB above 10 7 BER Predicting performance based upon signal quality varies with each loop Generally a noise margin of 0...

Страница 12: ..._ _____ 1 LOOPBACK TO NETWORK AT HTU C INACTIVE 2 LOOPBACK TO CUSTOMER AT HTU C INACTIVE 3 LOOPBACK TO NETWORK AT HTU R INACTIVE 4 LOOPBACK TO CUSTOMER AT HTU R INACTIVE Press corresponding number to...

Страница 13: ...provisioned from the HTU C All DTE port configuration must be done from the front panel Type M to return to the Main Menu Figure 13 Troubleshooting Screen TROUBLESHOOTING DISPLAY _____ _____ HTU C HTU...

Страница 14: ...7 a m 7 p m CST Emergency hours 7 days week 24 hours day ADTRAN Repair CAPS Return for repair upgrade 256 963 8722 Repair and Return Address ADTRAN Inc CAPS 901 Explorer Boulevard Huntsville Alabama 3...

Отзывы: