61245023L1-5B
Section 61245023L1-5B, Issue 2
13
Figure 12. Provisioning Options Screen
PROVISIONING
_____________________________________________________
| |
| PROVISIONS CURRENT SETTINGS |
| ------------------------------------------ |
| 1. DSX-1 LINE BUILDOUT = 0-133 FEET |
| 2. DSX-1/DS1 LINE CODE = B8ZS |
| 3. DSX-1/DS1 FRAMING = ESF |
| 4. LOOPBACK TIMEOUT = NONE |
| 5. DS1 OUTPUT LEVEL = N/A ON Nx64 HTU-R |
| 6. NIU LOOPBACK = ENABLED |
| 7. ALARM = N/A ON Nx64 HTU-R |
| 8. DS0 BLOCKING: |
| |
| 00000000 00000000 00000000 |
| CHANNELS 1 24 |
| “X” INDICATES A BLOCKED CHANNEL. |
|_____________________________________________________|
NOTE: Provisions can not be changed at the Nx64 HTU-R. ESF or SF
framing formats may be provisioned from the HTU-C. All DTE
port configuration must be done from the front panel.
Type “M” to return to the Main Menu.
Figure 13. Troubleshooting Screen
TROUBLESHOOTING DISPLAY
_____ _____
|HTU-C| |HTU-R|
| | | |
| | | |
--->| |<===========================>| |<—-
| | | |
NET | | | | CUST
| | | |
<---| |<===========================>| |-->
| | | |
| | | |
|_____| |_____|
Press “M” for Main Menu.
The Provisioning Options Screen is illustrated in
Figure 12
. Provisioning may be viewed by the
HTU-C but may not be changed. Provisioning
changes may only be implemented through the
Nx64.
The Troubleshooting Display Screen, illustrated in
Figure 13
, graphically depicts an HDSL circuit.
The unit reviews red, yellow, and blue alarm
conditions in the circuit to automatically predict
where a fault is located. Once a fault location is
suspected, the corresponding portion of the circuit
on the screen is highlighted and a message
describing the failure will appear.