Chapter 3. Operation
61200771L1-1
NxT1 HSSI/V.35 Module User Manual
37
Figure 3-4. HSSI Interface Loopback Test Diagram
LA
AND
LB
(Not applicable in V.35 mode.)
Displays the status of the loopback circuit A and B signals. LA and
LB are asserted by the DTE to enable a loopback on the DCE and
its associated data communications channel. Four possible loop-
back options are available:
TA
Displays the status of the data Terminal equipment Available signal.
TA will be asserted by the DTE (independently of CA) when the
DTE is prepared to both send and receive data to and from the
DCE. Valid data transmission should not commence until CA has
also been asserted by the DCE. If the data communications channel
requires a keep alive data pattern when the DTE is disconnected,
then the DCE shall supply this pattern while TA is deasserted.
When using the NxT1 HSSI Module (1200346L2 only) in V.35
mode, TA displays the status of the Request to Send (RTS) signal.
When RTS is active in a V.35 configuration, Clear to Send (CTS) is
also active.
NxT1 HSSI
IMUX
T1 Interfaces
DTE
Local Line Loopback
Remote Line Loopback
Local DTE Loopback
LA
LB
Loopback
Off
Off
No Loopback Active
On
On
Local DTE Loopback is Active
On
Off
Local Line Loopback is Active
Off
On
Remote Line Loopback is Active
Содержание NxT1 HSSI/V-35
Страница 1: ...NxT1 HSSI V 35 Module User Manual Part Number 1200771L1 61200771L1 1A March 2002...
Страница 16: ...List of Tables 16 NxT1 HSSI V 35 User Manual 61200771L1 1...
Страница 18: ...List of Figures 18 NxT1 HSSI V 35 User Manual 61200771L1 1...
Страница 40: ...Chapter 3 Operation 40 NxT1 HSSI V 35 Module User Manual 61200771L1 1...
Страница 46: ...Appendix A Dedicated Maps Configuration 46 NxT1 HSSI V 35 User Manual 61200771L1 1...
Страница 48: ...Index Index 48 NxT1 HSSI V 35 User Manual 61200771L1 1...