Configuring Your IAD
NetVanta 950 IAD Configuration Guide
28
© 2004 ADTRAN, Inc.
61200788L1-29.1B
11
IAD (config-fxs 5/1-8, fxs 6/1-4)#
forward-disconnect battery reverse
Configures the FXS interfaces to reverse the
battery polarity on the circuit when the remote
equipment ends the call
12
IAD (config-fxs 5/1-8, fxs 6/1-4)#
dnis-wink-timeout
Configures the FXS interface to return a wink to
the originating switch after five seconds if it does
not detect an off-hook condition
13
IAD (config-fxs 5/1-8, fxs 6/1-4)#
dnis-delay 1000
Configures the FXS interfaces to delay 1 second
before activating an off-hook condition
14
IAD (config-fxs 5/1-8, fxs 6/1-4)#
dial-tone
Configures the FXS interfaces to provide
dial-tone
15
IAD (config-fxs 5/1-8, fxs 6/1-4)#
ringback
Configures the FXS interfaces to provide ringback
16
IAD (config-fxs 5/1-8, fxs 6/1-4)# no
shutdown
Activate all FXS interfaces from Slot 5/1 to Slot
6/4
17
IAD (config-fxs 5/1-8, fxs 6/1-4)# exit
Exit to Global configuration mode
18
IAD (config)# cross-connect range 25 t1
0/2 1.1 fxs 5/1, fxs 6/4
Create a connection between T1 0/2 TDM group
1, DS0 1 and FXS 5/1 through DS0 12 and FXS
6/4
19
IAD (config)# exit
Exit Global configuration mode
This configuration must be saved to maintain settings after a unit reboot. Type
copy
running-config startup-config
to save the running configuration to the start-up
configuration.
Step
Command
Description