NetVanta 1224STR DC Hardware Installation Guide
Unit Installation
61200590E1-34B
Copyright © 2013 ADTRAN, Inc.
39
Figure 16. Grounding the NetVanta 1224STR DC
Installing Dial Backup and Network Interface Modules
The DIM plugs on to the NIM. The NIM is then installed into the rear panel option module slot. The following
tables list the installation steps. Also, see
.
For NetVanta modules with outside plant connections, ensure that all cables are
removed from the module before installing or removing it from the NetVanta chassis.
•
Always remove power from the unit prior to removing or installing a module.
•
Improper installation may result in damage to the modules.
•
Electronic modules can be damaged by static electrical discharge. Before handling
modules, put on an antistatic discharge wrist strap to prevent damage to electrical
components. Place modules in antistatic packing material when transporting or
storing. When working on modules, always place them on an approved antistatic mat
that is electrically grounded.