NetVanta T1/FT1 NEBS NIM (P/N 1200862L2#NEBS)

The T1/FT1 NEBS NIM (see Figure 13) T1 WAN interface for the NetVanta 1224STR DC. The T1 NEBS 
NIM is NEBS Level 3 compliant, and provides a full T1 or fractional T1 network interface. See Table A-6 
on page 53 for the WAN-T1 connector pinouts.

Figure 13.  NetVanta T1/FT1 NEBS NIM

Although the T1/FT1 NEBS NIM is compliant with NEBS Level 3, the NetVanta 1224STR 
DC unit supports only NEBS Level 1.

WAN-T1

Features and Specifications

Operating Modes

Frame Relay, Multilink Frame Relay

PPP, Multilink PPP

HDLC

T1/FT1 Interface

Supported Standards: AT&T TR 62411, 
AT&T TR 65016, ANSI T1.403, 
Bellcore TR 194

Line Rate: 1.544 Mbps + 75 bps

Line Code: AMI or B8ZS

Framing: D4 (SF) or ESF

FT1 Line Rate: DS0 channelized (multiples 
of 64 kbps)

Input Signal: 0 to -36 dB (DS1)

Line Build-Out: 0, -7.5, -15, -22.5 dB 
(long), 0 to 655 ft (short)

DS0 Assignment: Programmable

Connector: RJ-48C

Clock Source 

Network

Internal

Diagnostics

Test Pattern Generation and Detection: 
QRSS, 511, 2

15 

- 1, 2

20 

- 1, all ones, 

all zeros

Network loopbacks (local and remote); 
responds to inband and FDL loop codes 

Alarm generation and detection

Network and user sets of performance data 
(15 minutes and 24 hours)

Compliance

EMC - see 

Electromagnetic Compatibility 

(EMC) Table for the NetVanta 
1224STR/1224R 

on page 6.

NEBS Level 3

GR-63-CORE

GR-1089-CORE

UL/CUL 60950

Environmental

Operating Temperature: 0°C to 50°C

Storage Temperature: -20°C to 70°C

Relative Humidity: Up to 95 percent 
noncondensing

Physical

Dimensions: 2.75-inch W x 4.25-inch D

Содержание NetVanta 1000R Series

Страница 1: ...dule 1200872L1 NetVanta Dual T1 Network Interface Module 1200868E1 L1 NetVanta E1 FE1 Network Interface Module 1200878E1 L1 NetVanta E1 FE1 G 703 Drop Network Interface Module 1200866E1 L1 NetVanta Se...

Страница 2: ...of this publication Software Licensing Agreement Each ADTRAN product contains a single license for ADTRAN supplied software Pursuant to the Licensing Agreement you may a use the software on the purch...

Страница 3: ...00L1 34J Copyright 2006 ADTRAN Inc 3 Conventions Notes provide additional useful information Cautions signify information that could prevent service interruption or damage to the equipment Warnings pr...

Страница 4: ...han a cordless type during an electrical storm There is a remote risk of shock from lightning 3 Do not use the telephone to report a gas leak in the vicinity of the leak 4 Use only the power cord powe...

Страница 5: ...to the telephone network or premises wiring using an FCC compatible modular jack which is compliant with Part 68 and requirements adopted by ACTA 7 The following information may be required when apply...

Страница 6: ...1224R NetVanta Module P N and Name NetVanta 1224STR AC 1224R NetVanta 1224STR DC 1200861L1 56K 64K NIM FCC Part 15 Class A EN 55022 Class A N A 1200862L2 NEBS T1 FT1 NEBS NIM N A FCC Part 15 Class A...

Страница 7: ...e indicates the maximum number of terminals that can be connected to a telephone interface The termination on an interface may consist of any combination of devices subject only to the requirement tha...

Страница 8: ...and Product Service CaPS department to have an RMA number issued CaPS should also be contacted to obtain information regarding equipment currently in house or possible fees associated with repair Iden...

Страница 9: ...e ADTRAN Custom Extended Services ACES program offers multiple types and levels of installation and maintenance services which allow you to choose the kind of assistance you need This support is avail...

Страница 10: ...Product Support Information NetVanta 1000 1000R Series Hardware Installation Guide 10 Copyright 2006 ADTRAN Inc 61200500L1 34J...

Страница 11: ...ion 21 Front Panel RJ 45 Ports and LEDs 21 Front Panel Gigabit Ethernet Interfaces and LEDs 21 Other Front Panel LEDs 21 SFP Module Slots 22 Reviewing the Rear Panel Design 24 Option Modules 25 Networ...

Страница 12: ...Table of Contents NetVanta 1000 1000R Series Hardware Installation Guide 12 Copyright 2006 ADTRAN Inc 61200500L1 34J...

Страница 13: ...24 Figure 9 NetVanta 1224STR DC Rear Panel Layout 24 Figure 10 NetVanta 1524ST Rear Panel Layout 24 Figure 11 NetVanta 56K 64K NIM 26 Figure 12 NetVanta T1 FT1 NIM 27 Figure 13 NetVanta T1 FT1 NEBS N...

Страница 14: ...List of Figures NetVanta 1000 1000R Series Hardware Installation Guide 14 Copyright 2006 ADTRAN Inc 61200500L1 34J...

Страница 15: ...le A 5 WAN DDS Connector Pinouts 53 Table A 6 WAN T1 Connector Pinouts 53 Table A 7 WAN E1 Connector Pinouts 53 Table A 8 DSX 1 Connector Pinouts 54 Table A 9 G 703 Connector Pinouts 54 Table A 10 WAN...

Страница 16: ...List of Tables NetVanta 1000 1000R Series Hardware Installation Guide 16 Copyright 2006 ADTRAN Inc 61200500L1 34J...

Страница 17: ...e fiber slots have precedence NetVanta 1224STR AC and NetVanta 1224R The NetVanta 1224STR AC version and NetVanta 1224R are managed switches containing a multi service router housed in a 1U high rack...

Страница 18: ...Annex A 1200889E1 L1 ADSL NIM Annex B 1200864L1 Analog Modem DIM 1200865L1 ISDN BRI DIM 1200875L1 ISDN S T DIM 1200886L1 Serial DIM NetVanta 1524ST The NetVanta 1524ST is a Layer 2 managed switch hous...

Страница 19: ...After unpacking the unit inspect it for possible shipping damage If the equipment has been damaged in transit immediately file a claim with the carrier and contact ADTRAN Customer Service refer to Re...

Страница 20: ...D D VLAN Support 802 1Q up to 255 active VLANs D D D D D D D Priority QoS 802 1p D D D D D D D Management Console D D D D D D D Telnet CLI D D D D D D D SSH CLI D D D D D D D SNMP V2 D D D D D D D Po...

Страница 21: ...ge 22 or the RJ 45 jacks These interfaces are labeled G1 and G2 and their status LEDs also labeled G1 and G2 are located to the left of RJ 45 port 1 above the STAT LED on the NetVanta 1224ST and 1224S...

Страница 22: ...etVanta 1224ST and 1224STR PWR support two SFP slots the NetVanta 1224STR has one and the NetVanta 1524ST has four All accept a number of industry standard SFP modules The SFP modules provide Gigabit...

Страница 23: ...lid Port is enabled and has a link Amber flashing Port has activity transmit or receive DBU 1224R and 1224STR only Off No DIM is installed Green solid DIM is ready For the ISDN BRI DIM green solid ind...

Страница 24: ...NSOLE used for connecting to a VT100 terminal or a PC running VT100 terminal emulation software The NetVanta 1524ST has a rear panel Ethernet port labeled ETH 0 0 The NetVanta 1224STR and NetVanta 122...

Страница 25: ...etVanta E1 FE1 NIM P N 1200868E1 L1 on page 31 NetVanta E1 FE1 G 703 Drop NIM P N 1200878E1 L1 on page 32 NetVanta Serial NIM P N 1200866E1 L1 on page 33 NetVanta SHDSL NIM P N 1200867L1 on page 34 Ne...

Страница 26: ...ired for dial backup applications Figure 11 NetVanta 56K 64K NIM Features and Specifications Operating Modes Dedicated DDS leased line DDS Interface Supported Standards AT T TR 62310 4 wire full duple...

Страница 27: ...ANSI T1 403 Bellcore TR 194 Line Rate 1 544 Mbps 75 bps Line Code AMI or B8ZS Framing D4 SF or ESF FT1 Line Rate DS0 channelized multiples of 64 kbps Input Signal 0 to 36 dB DS1 Line Build Out 0 7 5 1...

Страница 28: ...T T TR 65016 ANSI T1 403 Bellcore TR 194 Line Rate 1 544 Mbps 75 bps Line Code AMI or B8ZS Framing D4 SF or ESF FT1 Line Rate DS0 channelized multiples of 64 kbps Input Signal 0 to 36 dB DS1 Line Buil...

Страница 29: ...ate DS0 channelized multiples of 56 64 kbps Input Signal 0 to 36 dB DS1 Line Build Out 0 7 5 15 22 5 dB long 0 to 655 ft short DS0 Assignment Programmable Connector RJ 48C DSX 1 Interface Line Interfa...

Страница 30: ...44 Mbps 75 bps Line Code AMI or B8ZS Framing D4 SF or ESF FT1 Line Rate DS0 channelized multiples of 64 kbps Input Signal 0 to 36 dB DS1 Line Build Out 0 7 5 15 22 5 dB long 0 to 655 ft short DS0 Assi...

Страница 31: ...nterface Supported Standards ITU G 703 ITU T G 704 CRC 4 ITU T G 823 ITU T G 797 Line Rate 2 048 Mbps 50 PPM Line Code AMI or HDB3 Framing FAS with optional CRC 4 FE1 Line Rate Channelized timeslot in...

Страница 32: ...T G 704 CRC 4 ITU T G 823 ITU T G 797 Line Rate 2 048 Mbps 50 PPM Line Code AMI or HDB3 Framing FAS with optional CRC 4 FE1 Line Rate Channelized timeslot in multiples of 64 kbps Receiver Sensitivity...

Страница 33: ...ptional DIM is required for dial backup applications Figure 18 NetVanta Serial NIM Cable length for the Serial NIM should not exceed 25 feet SERIAL DBU Features and Specifications Operating Mode DTE o...

Страница 34: ...ation CPE SHDSL Interface Supported Standards ITU T G 991 2 SHDSL Line Rate 200 to 2312 kbps in 64k increments Line Code TC PAM Connector RJ 45 Clock Source CPE Operating Mode Network CO Operating Mod...

Страница 35: ...ver POTS Annex A Supported Standards ITU G 992 1 G dmt ITU G 992 2 G lite ITU G 992 3 ADSL2 G dmt bis ITU G 992 5 ADSL2 ANSI T1 413 Issue 2 Reach Extended ADSL READSL2 Connector RJ 11C 6 pin jack inne...

Страница 36: ...ecifications ADSL Interface ADSL over ISDN Annex B Supported Standards ITU G 992 1 G dmt Connector RJ 11C 6 pin jack inner pair ATM Multiple Protocol over AAL5 RFC2684 PPP over ATM RFC2364 PPP over Et...

Страница 37: ...nstructions refer to Installing Dial Backup and Network Interface Modules on page 46 Features and Specifications Features Supported Standards ITU V 90 Async Compliance EMC see on page 6 ACTA FCC Part...

Страница 38: ...Installing Dial Backup and Network Interface Modules on page 46 Features and Specifications Features Clear Channel and bonding mode 1 call protocols Network support for 64 kbps 1 B channel or 128 kbp...

Страница 39: ...Backup and Network Interface Modules on page 46 Features and Specifications Features Clear channel and bonding mode 1 call protocols Network support for 64 kbps 1 B channel or 128 kbps 2 B channels D...

Страница 40: ...onnects to the NIM For installation instructions see Installing Dial Backup and Network Interface Modules on page 46 Features and Specifications Features 5 pin RS 232 interface vial host RJ 45 DBU con...

Страница 41: ...tools required for the hardware installation of the NetVanta are Ethernet cables Network cables module dependent DSX 1 cable T1 FT1 DSX 1 module only DBU cable dial backup functions require an option...

Страница 42: ...Accelerator Card install it first refer to Installing the NetVanta VPN Accelerator Card P N 1202368L1 on page 48 Instructions for Rack Mounting the NetVanta Step Action 1 To allow proper grounding scr...

Страница 43: ...r the NetVanta Keep in mind that the unit needs to be mounted at or below eye level so that the LEDs are viewable 3 Prepare the mounting surface by attaching a board typically plywood 3 4 inch to 1 in...

Страница 44: ...nta 1000 and 1000R Series AC Powered Units The AC powered NetVanta 1000 and 1000R Series units come equipped with an auto sensing 100 to 250 VAC 50 60 Hz power supply for connecting to a properly grou...

Страница 45: ...er connector Power to the NetVanta 1224STR DC System must be from a reliably grounded 24 or 48 VDC Use only copper conductors when making power connections Install unit in accordance with the requirem...

Страница 46: ...prior to removing or installing a module Improper installation may result in damage to the modules Instructions for Installing the DIMs Step Action 1 Remove power from the unit 2 If the NIM is alread...

Страница 47: ...NIM and DIM Installation Instructions for Installing the NIMs Step Action 1 Remove power from the unit 2 Slide the option module into the option slot until the module is firmly seated against the cha...

Страница 48: ...he card does not exceed 2 watts Figure 26 NetVanta VPN Card Installation The NetVanta VPN accelerator card is intended to be serviced installed by qualified service personnel only Instructions for Ins...

Страница 49: ...anta is now ready to be configured and connected to the network For more information on configuration for a specific application refer to the quick configuration documents provided on your ADTRAN OS S...

Страница 50: ...Unit Installation NetVanta 1000 1000R Series Hardware Installation Guide 50 Copyright 2006 ADTRAN Inc 61200500L1 34J...

Страница 51: ...escription 1 DCD Data Carrier Detect output 2 RD Receive Data output 3 TD Transmit Data input 4 DTR Data Terminal Ready input 5 SG Signal Ground 6 DSR Data Set Ready Tied to pin 1 output 7 Unused 8 CT...

Страница 52: ...TX2 Transmit Negative 3 RX1 Receive Positive 4 5 Unused 6 RX2 Receive Negative 7 8 Unused Table A 4 1000BaseT Gigabit Ethernet Port Pinouts Pin Name Description 1 TRD0 Transmit Receive Positive 2 TRD...

Страница 53: ...the network Tip 8 R Receive data from the network Ring Table A 6 WAN T1 Connector Pinouts Pin Name Description 1 R1 Receive data from the network Ring 1 2 T1 Receive data from the network Tip 1 3 Unu...

Страница 54: ...a from the DTE Tip 1 6 8 Unused Table A 9 G 703 Connector Pinouts Pin Name Description 1 R Transmit data toward the DTE Ring 2 T Transmit data toward the DTE Tip 3 Unused 4 R1 Receive data from the DT...

Страница 55: ...V 35 Pin X 21 Pin EIA 530 Pin Name 1 P 2 2 TD_A 2 U N A 24 ETC_A 3 Y N A 15 TCLK_A 4 V 6 17 RCLK_A 5 R 4 3 RD_A 6 F N A 8 DCD_A 7 H N A 20 DTR_A 8 C 3 4 RTS_A 9 N A 10 19 RTS_B V 11 only 10 N A 12 13...

Страница 56: ...tions Table A 13 Analog Modem and ISDN BRI DBU Connector Pinouts Pin Name Description 1 3 Unused 4 R Network Ring 5 T Network Tip 6 8 Unused Table A 14 ISDN S T DBU Connector Pinouts Pin Name Descript...

Страница 57: ...iption 17 NetVanta 1224R brief description 17 NetVanta 1224ST brief description 17 NetVanta 1224STR AC brief description 17 NetVanta 1224STR DC brief description 18 NetVanta 1524ST brief description 1...

Страница 58: ...slots 18 22 SHDSL interface 34 SHDSL NIM 34 shipment contents of 19 damage during transit 19 inspection of 19 specifications 20 STAT LED 23 STK LED 23 T T1 dual module 30 T1 FT1 DSX 1 module 29 T1 FT...

Отзывы: